Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background Retrospective studies have shown promising results using artificial intelligence (AI) to improve mammography screening accuracy and reduce screen-reading workload; however, to our knowledge, a randomised trial has not yet been conducted. We aimed to assess the clinical safety of an AI-supported screen-reading protocol compared with standard screen reading by radiologists following mammography.Methods In this randomised, controlled, population-based trial, women aged 40-80 years eligible for mammography screening (including general screening with 1·5-2-year intervals and annual screening for those with moderate hereditary risk of breast cancer or a history of breast cancer) at four screening sites in Sweden were informed about the study as part of the screening invitation. Those who did not opt out were randomly allocated (1:1) to AI-supported screening (intervention group) or standard double reading without AI (control group). Screening examinations were automatically randomised by the Picture Archive and Communications System with a pseudo-random number generator after image acquisition. The participants and the radiographers acquiring the screening examinations, but not the radiologists reading the screening examinations, were masked to study group allocation. The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale that was used to triage screening examinations to single reading (score 1-9) or double reading (score 10), with AI risk scores (for all examinations) and computer-aided detection marks (for examinations with risk score 8-10) available to the radiologists doing the screen reading. Here we report the prespecified clinical safety analysis, to be done after 80 000 women were enrolled, to assess the secondary outcome measures of early screening performance (cancer detection rate, recall rate, false positive rate, positive predictive value [PPV] of recall, and type of cancer detected [invasive or in situ]) and screen-reading workload. Analyses were done in the modified intention-to-treat population (ie, all women randomly assigned to a group with one complete screening examination, excluding women recalled due to enlarged lymph nodes diagnosed with lymphoma). The lowest acceptable limit for safety in the intervention group was a cancer detection rate of more than 3 per 1000 participants screened. The trial is registered with ClinicalTrials.gov, NCT04838756, and is closed to accrual; follow-up is ongoing to assess the primary endpoint of the trial, interval cancer rate.Findings Between April 12, 2021, and July 28, 2022, 80 033 women were randomly assigned to AI-supported screening (n=40 003) or double reading without AI (n=40 030). 13 women were excluded from the analysis. The median age was 54·0 years (IQR 46·7-63·9). Race and ethnicity data were not collected. AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings. Standard screening among 40 024 participants resulted in 203 screen-detected cancers, 817 recalls, and a total of 83 231 screen readings. Cancer detection rates were 6·1 (95% CI 5·4-6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4-5·8) per 1000 in the control group-a ratio of 1·2 (95% CI 1·0-1·5; p=0·052). Recall rates were 2·2% (95% CI 2·0-2·3) in the intervention group and 2·0% (1·9-2·2) in the control group. The false positive rate was 1·5% (95% CI 1·4-1·7) in both groups. The PPV of recall was 28·3% (95% CI 25·3-31·5) in the intervention group and 24·8% (21·9-28·0) in the control group. In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ. The screen-reading workload was reduced by 44·3% using AI.Interpretation AI-supported mammography screening resulted in a similar cancer detection rate compared with standard double reading, with a substantially lower screen-reading workload, indicating that the use of AI in mammography screening is safe. The trial was thus not halted and the primary endpoint of interval cancer rate will be assessed in 100 000 enrolled participants after 2-years of follow up.Funding Swedish Cancer Society, Confederation of Regional Cancer Centres, and the Swedish governmental funding for clinical research (ALF).
Overview
CoChat Summary
TL;DR
In the MASAI trial, AI-supported screen reading resulted in a similar cancer detection rate to standard double reading (6·1 vs 5·1 per 1000 screened; ratio 1·2, 95% CI 1·0–1·5) and reduced screen-reading workload by 44·3%. The prespecified safety analysis supported continuing the trial to assess the primary endpoint of interval cancer rate.
Key findings
- Cancer detection rate was 6·1 per 1000 screened participants (95% CI 5·4–6·9) in the AI-supported group versus 5·1 per 1000 (4·4–5·8) in the control group, a ratio of 1·2 (95% CI 1·0–1·5; p=0·052), above the prespecified lowest acceptable safety limit of more than 3 per 1000.
- Recall rate was 2·2% (95% CI 2·0–2·3) with AI versus 2·0% (1·9–2·2) in controls; false positive rate was 1·5% (95% CI 1·4–1·7) in both groups; PPV of recall was 28·3% (25·3–31·5) versus 24·8% (21·9–28·0).
- AI-supported screening detected 244 cancers (184 [75%] invasive, 60 [25%] in situ) among 39,996 participants; standard screening detected 203 cancers (165 [81%] invasive, 38 [19%] in situ) among 40,024 participants.
- Screen-reading workload was reduced by 44·3% with AI: 46,345 readings versus 83,231 readings.
Methods
- Randomised, controlled, population-based, non-inferiority, single-blinded screening accuracy study at four Swedish screening sites; women aged 40–80 years eligible for mammography screening were randomly allocated 1:1 to AI-supported screening (n=40,003) or standard double reading without AI (n=40,030); 13 women were excluded, leaving a modified intention-to-treat population.
- The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale, triaging examinations with score 1–9 to single reading and score 10 to double reading; AI risk scores and computer-aided detection marks (for scores 8–10) were available to radiologists.
- This prespecified clinical safety analysis, performed after 80,000 women were enrolled, assessed early screening performance (cancer detection rate, recall rate, false positive rate, PPV of recall, and type of cancer detected) and screen-reading workload.
Limitations
- Stated in the paper: race and ethnicity data were not collected; follow-up is ongoing to assess the primary endpoint of interval cancer rate, so this report covers early screening performance rather than final trial outcomes.
- Evident from the text: the findings come from a single trial in Sweden using one AI system and version, so longer-term outcomes and broader generalisability remain to be established.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 0 Not checked · 31 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The PPV of recall was 28·3% (95% CI 25·3–31·5) in the intervention group and 24·8% (21·9–28·0) in the control group.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings.”
plainn = 39,996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 24- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
15 more claims
Create a free account to see all 31 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As shown in Figure 2A, AI agents possess the capacity to process extensive patient data, including medical histories, diagnostic test results, and imaging, thereby aiding healthcare professionals in making more informed and precise diagnostic decisions.62,63,64,65,66,67,68,69”
From A foundational architecture for AI agents in healthcare (2025) · cites this paper as [67]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“Likewise, AI exhibits promising potential in oncology and radiology for automatically identifying and categorising neoplastic lesions observed in thoracic and abdominal imaging, including X-ray, computed tomography (CT) and the more challenging magnetic resonance (MR) imaging.5,6”
From Artificial intelligence and endo-histo-omics: new dimensions of precision endoscopy and histology in inflammatory bowel disease (2024) · cites this paper as [5]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Self-citationDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Transparency in artificial intelligence
Larsson, S., & Heintz, F. (2020) · Internet Policy Review · doi:10.14763/2020.2.1469 · Cited by 458
Self-citationSechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Dembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines
Schünemann, H. J., Lerda, D., Quinn, C., Follmann, M., Alonso-Coello, P., Rossi, P. G., Lebeau, A., Nyström, L., Broeders, M., Ioannidou-Mouzaka, L., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2125 · Cited by 286
Self-citation
Cited by
Items 401–500 of 596
Five years into the Future of Surgery
Butler, M. (2023) · Bulletin of The Royal College of Surgeons of England · doi:10.1308/rcsbull.2023.135
AI in Screening Mammography: Use One Radiologist and Improve Double Reads
Nishikawa, R. M., & Lu, A. H. (2023) · Radiology · doi:10.1148/radiol.232964
Commentary: Artificial Intelligence in nursing: trustworthy or reliable?
Dowding, D. (2024) · Journal of research in nursing · doi:10.1177/17449871231215746
Bitencourt, A. G. V. (2024) · European Radiology · doi:10.1007/s00330-024-10761-0
Further adventures in AI-directed double reading (AID-DR) for single reading environments
Nishikawa, R. M., Lu, A. H., & Hoffmeister, J. W. (2024) · International Workshop on Breast Imaging (IWBI) · doi:10.1117/12.3026261
Strukturierte Früherkennung des sporadischen Mammakarzinoms
Weigel, S., & Katalinic, A. (2024) · best practice onkologie · doi:10.1007/s11654-024-00582-4
Decoding Precision Cancer Care: AI’s Evolution from Data to Decision and Recent Breakthroughs
Zhao, X., Blum, J., Menta, A. K., Yang, V., & Subbiah, V. (2024) · AI in Precision Oncology · doi:10.1089/aipo.2024.0013
Optimizing the Use of Artificial Intelligence in Cardiology in 2024
Ellis, S. G., & Kattan, M. W. (2024) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2024.05.016
Yu, Y., Ren, W., Mao, L., Ouyang, W., Hu, Q., Yao, Q., Tan, Y., He, Z., Ban, X., Hu, H., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4894775
Initial interpretation scores of screening mammograms and cancer detection in BreastScreen Norway
Hovda, T., Sagstad, S., Moshina, N., Vigeland, E., & Hofvind, S. S. H. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111662
Self-citationKrumsvik, R. J. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4938658
Anais do Simpósio Brasileiro de Inteligência Artificial
Pontes, M. R., Damasceno, M. N., da Silva, G. L., & Mariquito, M. F. A. (2024) · Editora Pascal LTDA eBooks · doi:10.29327/5424868
Strukturierte Früherkennung des sporadischen Mammakarzinoms
Weigel, S., & Katalinic, A. (2024) · Forum · doi:10.1007/s12312-024-01377-y
Kulkarni, S. R. (2024) · Indian Journal of Breast Imaging · doi:10.25259/ijbi_17_2023
Weigel, S., Hense, H., Weyer‐Elberich, V., Gerß, J., & Heindel, W. L. (2024) · TumorDiagnostik & Therapie · doi:10.1055/a-2389-6721
Wang, L. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1005912
Wenkel, E. (2024) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2367-9463
Zackrisson, S., & Bolejko, A. (2024) · European Journal of Radiology · doi:10.1016/j.ejrad.2024.111870
OECD (2024) · OECD health policy studies · doi:10.1787/964ad13f-sl
OECD (2024) · OECD health policy studies · doi:10.1787/0cdc42ae-fr
OECD (2024) · OECD health policy studies · doi:10.1787/c0f28aca-en
Oncologia e Hematologia - Edição X
Freitas, G. B. L. D., & Resende, A. F. P. (2024) · doi:10.59290/978-65-6029-191-1
Embracing change: The potential of artificial intelligence in transforming surgical practice
Sadiq, K. O. (2025) · The Surgeon · doi:10.1016/j.surge.2025.01.002
Personal Profiling im Bereich der Senologie
Behrens, A. S., Beckmann, M. W., Fasching, P. A., Huebner, H., & Emons, J. (2025) · Die Radiologie · doi:10.1007/s00117-024-01410-0
Einsatz der künstlichen Intelligenz in der Diagnostik und Therapie solider Tumoren
Peeken, J. C., & Kather, J. N. (2025) · Die Onkologie · doi:10.1007/s00761-025-01683-7
Weigel, S., Hense, H., Weyer‐Elberich, V., Gerß, J., & Heindel, W. L. (2025) · Senologie - Zeitschrift für Mammadiagnostik und -therapie · doi:10.1055/a-2510-3262
Shapiro, J., Avitan‐Hersh, E., Greenfield, B., Khamaysi, Z., Dodiuk‐Gad, R. P., Valdman‐Grinshpoun, Y., Freud, T., & Lyakhovitsky, A. (2025) · JDDG Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/ddg.15609_g
Establishing the Evidence Needed for AI-driven Mammography Screening
Milch, H. S., & Lee, C. I. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.250152
Inteligencia artificial en el diagnóstico por imagen de patología mamaria
Benito, M. Á., Elías-Cabot, E., & Romero-Martín, S. (2025) · Revista de Senología y Patología Mamaria · doi:10.1016/j.senol.2025.100684
Künstliche Intelligenz im Krebsscreening
Schneider, C. V., Brinker, T. J., Foersch, S., Truhn, D., Hann, A., & Kather, J. N. (2025) · Die Onkologie · doi:10.1007/s00761-025-01719-y
Navegando por la OncoEvolución: el futuro del cáncer cuidado en la era del big data y las máquinas
Pino, L. E. (2024) · Medicina · doi:10.56050/01205498.2367
Traffic Light Coding System for Engaging With AI in Surgery
Mukherjee, P., Beheshti, A., Kumar, S. A., Wallace, G. G., Merrett, N. D., Clark, J. R., Kos, S., Rawstron, E., Yang, J. Y., Grieve, S. M., et al. (2025) · ANZ Journal of Surgery · doi:10.1111/ans.70172
Techniques d’imagerie numérique en mammographie, angiomammographie et tomosynthèse
Arfi, J., Boyer, B., & Balleyguier, C. (2025) · EMC - Radiologie et imagerie médicale - Génito-urinaire - Gynéco-obstétricale - Mammaire · doi:10.1016/s1879-8543(25)48633-9
Conti, L., Capetti, B., Battaglia, O., Grasso, R., Pesapane, F., Monzani, D., & Pravettoni, G. (2025) · doi:10.2196/preprints.78955
Jiménez-Pastor, A., Bataller, F. B., & Blanco, A. M. A. (2025) · Springer eBooks · doi:10.1007/978-3-031-89963-8_10
Dahl, F. A., & Hofvind, S. S. H. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-98691-8_3
Self-citationKI in der Diagnostik – die Sicht der Radiologie
Müller, L., Jorg, T., & dos Santos, D. P. (2025) · Die Onkologie · doi:10.1007/s00761-025-01773-6
Burger, H., & Albert Hofman, D. (2025) · doi:10.1007/978-90-368-3098-0_1
Kather, J. N. (2025) · Springer eBooks · doi:10.1007/978-3-662-71042-5_5
Grundlagen der Anwendung von KI in der Medizin
Kather, J. N. (2025) · Springer eBooks · doi:10.1007/978-3-662-71042-5_4
Der Mensch und die KI – unser neues Gegenüber
Kather, J. N. (2025) · Springer eBooks · doi:10.1007/978-3-662-71042-5_3
Silva, T. B. (2025) · Journal of Cancer Prevention & Current Research · doi:10.15406/jcpcr.2025.16.00578
Einsatzmöglichkeiten künstlicher Intelligenz in Gynäkologie und Geburtshilfe
Fehm, T. N., & Behrens, B. (2025) · Die Gynäkologie · doi:10.1007/s00129-025-05412-4
Design of a Telemedicine System for Classification of Breast Cancer Images
Nguyen, T.-T., Hải, N. T., & Nguyen, T.-T. (2025) · Technical Education Science/Giáo dục Kỹ thuật · doi:10.54644/jte.2025.1969
The Legacy of the COVID-19 Pandemic in Cancer Care
Roe, H. (2025) · Springer eBooks · doi:10.1007/978-3-031-33855-7_13
Corte, T. D., Verhaeghe, J., Ongenae, F., Waele, J. J. D., & Hoecke, S. V. (2025) · Applied Sciences · doi:10.3390/app152010933
Dépistage du cancer du sein : perspectives de la nouvelle génération de radiologues
de BAZELAIRE, C. (2025) · Imagerie de la Femme · doi:10.1016/j.femme.2025.07.004
AI and emerging technologies for diagnosis
Soundararajan, S. S., Selvakumar, J., Vijayalakshmi, S., & Baskaran, N. (2025) · Progress in brain research · doi:10.1016/bs.pbr.2025.08.004
Zukunftsperspektiven von Künstlicher Intelligenz in der Medizin
Kather, J. N. (2025) · Springer eBooks · doi:10.1007/978-3-658-47498-0_4
Mesurolle, B. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.25.34075
Lerma-Torres, D. C. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-09037-9_11
Ezura, M., Sawada, K., Takushima, Y., Teng, L., & Igarashi, A. (2025) · Journal of Market Access & Health Policy · doi:10.3390/jmahp13040057
Will Machines Take Over? Algorithms for Human-Machine Collaborative Decision Making in HealthcarePreprint
Ahsen, M. E., Ayvaci, M., & Mookerjee, R. V. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5744362
Fan, K. L., Thompson, Y. L. E., Chen, W., Abbey, C. K., & Samuelson, F. W. (2025) · Medical Decision Making · doi:10.1177/0272989x251388665 · Cited by 2
“Randomized clinical trials (RCTs), such as the MASAI trial, 28 represent an important step beyond our proposed analysis.”
Artificial Intelligence in Early Common Cancer Diagnosis: a Systematic Review
Le, M. B. C., & Bui, T. T. T. (2025) · Pacific Neighborhood Consortium Annual Conference and Joint Meetings (PNC) · doi:10.23919/pnc67749.2025.11245496 · Cited by 1
“More over, in this review, it can be showed that there are nine studies demonstrated that AI alone achieved high accuracy, sensitivity, and specificity, in some cases outperforming radiologists [19], [20], [25], [28], [29], [32], [36], [42], [43].”
Martinez, M. J. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.11.030
Traill, M., Jantz, J., Richards, B. J., Khalatbari, S. H., Hoffmeister, J. W., Shisler, J. L., & Snyder, C. (2025) · Clinical Breast Cancer · doi:10.1016/j.clbc.2025.11.007
Mammo-GAN-Assisted Deep Network Training Scheme for Lesion Detection
Lee, J., & Nishikawa, R. M. (2025) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-025-01771-5
“Lastly, investigators are currently evaluating breast cancer detection algorithms for triaging screening mammograms (e.g., [34, 35]) to identify a subset of screening cases as having a very low probability of containing a cancer that does not need to be read by a radiologist.”
A Data-Driven Framework for Disease Detection using Medical Imaging Analysis
Pandey, S. K., Krishnan, S. B., Mamodiya, U., & Chakrabarti, P. (2025) · International Conference on Innovative Data Communication Technologies and Application (ICIDCA) · doi:10.1109/icidca66325.2025.11280327
“Additionally to ViTs, we have multimodal learning that integrates image data with textual or other clinical metadata, which has been shown to positively impact diagnostic accuracy and clinical usability [7].”
Faviez, C., Chen, X., Garcelon, N., Zaidan, M., Billot, K., Petzold, F., Faour, H., Douillet, M., Rozet, J., Cormier‐Daire, V., et al. (2024) · Figshare · doi:10.6084/m9.figshare.25902422
Faviez, C., Chen, X., Garcelon, N., Zaidan, M., Billot, K., Petzold, F., Faour, H., Douillet, M., Rozet, J., Cormier‐Daire, V., et al. (2024) · Figshare · doi:10.6084/m9.figshare.25902330
Elhakim, M. T., Stougaard, S. W., Graumann, O., Nielsen, M., Lång, K., Gerke, O., Larsen, L. B., & Rasmussen, B. S. B. (2023) · Figshare · doi:10.6084/m9.figshare.24883584
Self-citationKwon, M.-R., Chang, Y., Ham, S.-Y., Cho, Y., Kim, E. Y., Kang, J., Park, E. K., Kim, K. H., Kim, M., Kim, T. S., et al. (2024) · Figshare · doi:10.6084/m9.figshare.25670105
Ceugnart, L., Miled, A. B., Aoud, I. E., Spriet, J., Lardemelle, C., & Fouasse, T. (2025) · Imagerie de la Femme · doi:10.1016/j.femme.2025.07.009
Intelligence artificielle en mammographie et en tomosynthèse ?
Taourel, P., & Pages-Bouic, E. (2025) · Imagerie de la Femme · doi:10.1016/j.femme.2025.07.005
Kusama, H., Horimoto, Y., Adachi, K., Koyama, Y., Orimoto, K., Kawate, T., Kimura, F., Komiya, T., Kaise, H., Yamada, K., et al. (2025) · Breast Cancer · doi:10.1007/s12282-025-01811-6
“According to the MASAI study, AI-supported screening reduced the reading work - load by 44% relative to the traditional double-reading sys - tem involving two physicians, while increasing the cancer detection rate by 29% [ 23, 24].”
The efficiency in breast cancer detection of PyCaret’s auto-ML with GLCM
Răducan, E., Radu, D., & Burlibaşa, A. (2025) · doi:10.1109/iseee67817.2025.11304829
Artificial Intelligence in Diagnosis
Cox, E. (2026) · Biomedical visualization · doi:10.1007/978-3-032-06520-9_4
Healy, N. A. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112663
Automated Breast Cancer Detection and Segmentation Using Image Processing Techniques
Shankar, A., Risby, G., Ling, H. H., Roy, T., & Ahanathapillai, V. (2025) · IEEE Symposium on Computers and Communications (ISCC) · doi:10.1109/iscc65549.2025.11326040
“While this has been shown to slightly reduce error, it drastically increases the overall workload and likely leads to lower efficiency and longer wait times, especially as the incidence of breast cancer increases[6].”
Cruz-Fernández, M., Velásquez, F. A. C., Fuentes-Silva, C., Rodríguez-Abreo, O., Rojas-Galván, R., Avilés, M., & Rodríguez‐Reséndiz, J. (2026) · Technologies · doi:10.3390/technologies14010066
Sossavi, E., Tardy, M., Hurstel, F., Schwartz, J., Wackenthaler, A., Harter, C., Uttner, J., Mollion, M., Bretz, M.-F., & Molière, S. (2026) · Cancer Imaging · doi:10.1186/s40644-026-00995-0
“Conversely, the MASAI randomized trial’s risk‐allocation triage halved workload without increasing recalls, preserving cancer detection rate (CDR) even in a live service setting [11, 12].”
Schlüssel zur Krebstherapie der Zukunft?
Kather, J. N. (2026) · InFo Hämatologie + Onkologie · doi:10.1007/s15004-025-1238-9
“In der radiologischen Diagnostik sind solche Systeme bereits weit fortgeschritten, beispielsweise zur Unterstützung bei der Mam-mografie-Befundung [2] oder der automatisierten Polypen-erkennung während der Endoskopie [3].”
The evolution of autonomous diagnostic workflows in cancer imaging
Truhn, D. (2026) · Annals of Oncology · doi:10.1016/j.annonc.2026.01.014
Artificial Intelligence Outperforms Radiologists in Pancreatic Cancer Detection
Zaheer, A. (2026) · American Journal of Roentgenology · doi:10.2214/ajr.26.34569
Artificial intelligence in oncology: from tools to teammates
Kather, J. (2026) · Annals of Oncology · doi:10.1016/j.annonc.2026.02.004
Dontchos, B. N., Narayan, A. K., Grimm, L. J., Edmonds, C. E., Lam, D. L., Lawson, M., & Miles, R. C. (2025) · Journal of Breast Imaging · doi:10.1093/jbi/wbaf061
Schilling, K. J., Hoffmeister, J., Sarquis-Kolber, S., Coates, N., & Shisler, J. L. (2026) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2026.02.014 · Cited by 1
Miao, X., Wang, J., Paerhati, H., Wu, A., & Zhang, M. (2026) · Current Medicinal Chemistry · doi:10.2174/0109298673443495251215073442
Robin, D. (2026) · Medical Humanities · doi:10.1136/medhum-2025-013454
Kommentar zu „MAMMA – Screeningmammografie: Befundung mithilfe von Künstlicher Intelligenz“
Blum, S. F. U. (2026) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/a-2718-1515
Thomason, C., Bucshon, L., Miller, B. J., & Yagi, B. F. (2026) · Health Affairs Scholar · doi:10.1093/haschl/qxag046
“…from images with 100% sensitivity, 23 automatically analyze brain CT scans in real time, 24 and improve performance by more accurately reading CT scans, 25 mammography, 26 and pathology slides 27 thus both automating components of clinical practice and enhancing the accuracy of clinical care.”
Jung, J.-J., Kim, H. Y., Kang, E. K., Park, E. K., Lee, H., Moon, H.-G., Cho, N., & Han, W. H. (2026) · Annals of Surgical Oncology · doi:10.1245/s10434-026-19348-z · Cited by 1
“14 Furthermore, AI algorithms have shown potential for individualized breast cancer risk prediction beyond traditional clinical models.”
Overview of Key Challenges and Opportunities
Scholz, S. (2026) · Springer eBooks · doi:10.1007/978-3-032-16837-5_3
AI for breast cancer screening
Hackshaw, A. K., & Given-Wilson, R. (2026) · Nature Cancer · doi:10.1038/s43018-025-01109-8
Galappaththi, D., de Silva, M., Jawed, M., & Shahid, S. M. (2026) · Diagnostics · doi:10.3390/diagnostics16060873
“A randomised control trial done in Sweden resulted in significantly lower screening workload by the AI-supported mammography screening when compared to standard double reading by the radiologists [14].”
Mamografi ve Dijital Meme Tomosentezinde Yapay Zekânın Rolü
Başar, Y. (2026) · Özgür Yayınları eBooks · doi:10.58830/ozgur.pub1254.c5098
Kwon, H., Kim, S. M., Oh, S. H., Jang, M., Kim, M.-G., Bae, H.-M., Choi, S. I., Cho, S. M., 김영민, Jung, G., et al. (2026) · Frontiers in Radiology · doi:10.3389/fradi.2026.1747783
Early Breast Cancer Detection Using Artificial Intelligence
Anitha, M., Prasad, C. R., & Awotunde, J. B. (2025) · International Conference on Recent Trends in Electrical, Electronics and Computing Technologies (ICRTEECT) · doi:10.1109/icrteect67512.2025.11448768
“In [9] the authors Deep learning (DL) AI approaches have been used more recently to create new algorithms that have been shown to greatly improve radiologists' ability to detect breast cancer.”
Alshreef, B. S. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6487560
Alarifi, M., Jabour, A. M., Abanomy, A., Alahmad, H., Alenazi, K., Alshedi, A., Almanaa, M., & Aloufi, A. S. (2026) · Tomography · doi:10.3390/tomography12040045 · Cited by 2
“Biopsy confirmation offers a decisive reference to evaluate diagnostic systems because it anchors analyses to ground truth rather than to follow-up imaging alone [29].”
InfluentialCribados e inteligencia, no solo artificial
Santaliestra, C. C. (2026) · Actualización en Medicina de Familia · doi:10.55783/amf.220309
Wang, Y. K., Cockmartin, L., Wagner, T., Klaneček, Ž., Marshall, N. W., Studen, A., Jeraj, R., & Bosmans, H. (2026) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.3084769
“4,5 Considering the promising results from prospective clinical trials, 6 the adoption of CAD models in screening programs is likely to become more widespread in the future.”
Automation bias and timing of artificial intelligence decision support in screening mammography
Gommers, J. J. J., Verboom, S. D., Broeders, M. J. M., & Sechopoulos, I. (2026) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.3086110 · Cited by 1
“The system has been trained and validated on large, multi-institutional datasets collected using equipment from various vendors and representing diverse populations across multiple screening programs (11,15–18) .”
Jiang, Z., Trieu, P. D., Taba, S. T., Barron, M. L., Gandomkar, Z., & Lewis, S. (2026) · SPIE Medical Imaging: Image Perception, Observer Performance, and Technology Assessment · doi:10.1117/12.3088026
“Several countries are using AI as a supported screening tool 6 or as a second reader 7 for mammogram interpretation in breast cancer screening programs.”
Will machines take over? Algorithms for human–machine collaborative decision making in healthcare
Ahsen, M. E., Mookerjee, R. V., & Ayvaci, M. (2026) · Production and Operations Management · doi:10.1177/10591478261443194 · Cited by 2
Janssen, I., Lotz, J., Hosseini, A. S. A., & Panahi, B. (2026) · Frauenheilkunde up2date · doi:10.1055/a-2576-5789
Digital therapeutics in cancer management and the emerging role of digital phenotyping
Cong, B., Xu, B., Chen, X., Ou, Y., Li, X., Liu, K., Zhang, S., Fu, C., Fan, J., Liu, Z., et al. (2026) · Displays · doi:10.1016/j.displa.2026.103502 · Cited by 1
Reducing false positives in breast cancer screening with computer-aided detection
Wan, T., Sang, X., Wu, Z. W., Li, L., Liu, N., & Yi, H. (2026) · Clinical and Experimental Medicine · doi:10.1007/s10238-026-02147-x
“Recent prospective/real-world studies suggest AI can reduce read - ing workload without increasing false positives, with some reporting declining recall/false-positive trends [11, 22 , 23 ].”
AI in cancer education and screening: Improving patient awareness and quality of life
Sharma, D., Pal, D., & Sharma, L. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45004-4.00001-3
Metadata
- Authors
- Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A.
- Affiliations
- Lund University (SE)
- Cancer Registry of Norway (NO)
- Corresponding author
- Lång, Kristina
- ORCID
- Venue
- The Lancet Oncology
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 24
- Issue
- 8
- Pages
- 936-944
- ISSN
- 1470-2045 (ISSN-L)
- OpenAlex
- W4385448527
- Semantic Scholar
- abba9a98a0a449e2e14bd6fc8813c996304ddace
- Cited by
- 598
- References
- 30
- Citations by year
- 2026: 197 · 2025: 205 · 2024: 164 · 2023: 31
- FWCI
- 56.30
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- The Lancet Oncology (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- Swedish Cancer Society (22 0611FE)
- Skånes universitetssjukhus
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- artificial intelligence, mammography screening, computer-aided detection, double reading, clinical safety, breast cancer detection, recall rate, false positive rate, positive predictive value, non-inferiority, breast cancer screening, breast cancer in situ
- MeSH terms
- Artificial Intelligence, Breast Neoplasms, Female, Humans, Mammography, Mass Screening, Middle Aged, Predictive Value of Tests, Retrospective Studies, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.