Artificial intelligence-supported screen reading versus standard double reading in the Mammography Screening with Artificial Intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background Retrospective studies have shown promising results using artificial intelligence (AI) to improve mammography screening accuracy and reduce screen-reading workload; however, to our knowledge, a randomised trial has not yet been conducted. We aimed to assess the clinical safety of an AI-supported screen-reading protocol compared with standard screen reading by radiologists following mammography.Methods In this randomised, controlled, population-based trial, women aged 40-80 years eligible for mammography screening (including general screening with 1·5-2-year intervals and annual screening for those with moderate hereditary risk of breast cancer or a history of breast cancer) at four screening sites in Sweden were informed about the study as part of the screening invitation. Those who did not opt out were randomly allocated (1:1) to AI-supported screening (intervention group) or standard double reading without AI (control group). Screening examinations were automatically randomised by the Picture Archive and Communications System with a pseudo-random number generator after image acquisition. The participants and the radiographers acquiring the screening examinations, but not the radiologists reading the screening examinations, were masked to study group allocation. The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale that was used to triage screening examinations to single reading (score 1-9) or double reading (score 10), with AI risk scores (for all examinations) and computer-aided detection marks (for examinations with risk score 8-10) available to the radiologists doing the screen reading. Here we report the prespecified clinical safety analysis, to be done after 80 000 women were enrolled, to assess the secondary outcome measures of early screening performance (cancer detection rate, recall rate, false positive rate, positive predictive value [PPV] of recall, and type of cancer detected [invasive or in situ]) and screen-reading workload. Analyses were done in the modified intention-to-treat population (ie, all women randomly assigned to a group with one complete screening examination, excluding women recalled due to enlarged lymph nodes diagnosed with lymphoma). The lowest acceptable limit for safety in the intervention group was a cancer detection rate of more than 3 per 1000 participants screened. The trial is registered with ClinicalTrials.gov, NCT04838756, and is closed to accrual; follow-up is ongoing to assess the primary endpoint of the trial, interval cancer rate.Findings Between April 12, 2021, and July 28, 2022, 80 033 women were randomly assigned to AI-supported screening (n=40 003) or double reading without AI (n=40 030). 13 women were excluded from the analysis. The median age was 54·0 years (IQR 46·7-63·9). Race and ethnicity data were not collected. AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings. Standard screening among 40 024 participants resulted in 203 screen-detected cancers, 817 recalls, and a total of 83 231 screen readings. Cancer detection rates were 6·1 (95% CI 5·4-6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4-5·8) per 1000 in the control group-a ratio of 1·2 (95% CI 1·0-1·5; p=0·052). Recall rates were 2·2% (95% CI 2·0-2·3) in the intervention group and 2·0% (1·9-2·2) in the control group. The false positive rate was 1·5% (95% CI 1·4-1·7) in both groups. The PPV of recall was 28·3% (95% CI 25·3-31·5) in the intervention group and 24·8% (21·9-28·0) in the control group. In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ. The screen-reading workload was reduced by 44·3% using AI.Interpretation AI-supported mammography screening resulted in a similar cancer detection rate compared with standard double reading, with a substantially lower screen-reading workload, indicating that the use of AI in mammography screening is safe. The trial was thus not halted and the primary endpoint of interval cancer rate will be assessed in 100 000 enrolled participants after 2-years of follow up.Funding Swedish Cancer Society, Confederation of Regional Cancer Centres, and the Swedish governmental funding for clinical research (ALF).
Overview
CoChat Summary
TL;DR
In the MASAI trial, AI-supported screen reading resulted in a similar cancer detection rate to standard double reading (6·1 vs 5·1 per 1000 screened; ratio 1·2, 95% CI 1·0–1·5) and reduced screen-reading workload by 44·3%. The prespecified safety analysis supported continuing the trial to assess the primary endpoint of interval cancer rate.
Key findings
- Cancer detection rate was 6·1 per 1000 screened participants (95% CI 5·4–6·9) in the AI-supported group versus 5·1 per 1000 (4·4–5·8) in the control group, a ratio of 1·2 (95% CI 1·0–1·5; p=0·052), above the prespecified lowest acceptable safety limit of more than 3 per 1000.
- Recall rate was 2·2% (95% CI 2·0–2·3) with AI versus 2·0% (1·9–2·2) in controls; false positive rate was 1·5% (95% CI 1·4–1·7) in both groups; PPV of recall was 28·3% (25·3–31·5) versus 24·8% (21·9–28·0).
- AI-supported screening detected 244 cancers (184 [75%] invasive, 60 [25%] in situ) among 39,996 participants; standard screening detected 203 cancers (165 [81%] invasive, 38 [19%] in situ) among 40,024 participants.
- Screen-reading workload was reduced by 44·3% with AI: 46,345 readings versus 83,231 readings.
Methods
- Randomised, controlled, population-based, non-inferiority, single-blinded screening accuracy study at four Swedish screening sites; women aged 40–80 years eligible for mammography screening were randomly allocated 1:1 to AI-supported screening (n=40,003) or standard double reading without AI (n=40,030); 13 women were excluded, leaving a modified intention-to-treat population.
- The AI system (Transpara version 1.7.0) provided an examination-based malignancy risk score on a 10-level scale, triaging examinations with score 1–9 to single reading and score 10 to double reading; AI risk scores and computer-aided detection marks (for scores 8–10) were available to radiologists.
- This prespecified clinical safety analysis, performed after 80,000 women were enrolled, assessed early screening performance (cancer detection rate, recall rate, false positive rate, PPV of recall, and type of cancer detected) and screen-reading workload.
Limitations
- Stated in the paper: race and ethnicity data were not collected; follow-up is ongoing to assess the primary endpoint of interval cancer rate, so this report covers early screening performance rather than final trial outcomes.
- Evident from the text: the findings come from a single trial in Sweden using one AI system and version, so longer-term outcomes and broader generalisability remain to be established.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 0 Not checked · 31 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the intervention group, 184 (75%) of 244 cancers detected were invasive and 60 (25%) were in situ; in the control group, 165 (81%) of 203 cancers were invasive and 38 (19%) were in situ.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The PPV of recall was 28·3% (95% CI 25·3–31·5) in the intervention group and 24·8% (21·9–28·0) in the control group.”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“AI-supported screening among 39 996 participants resulted in 244 screen-detected cancers, 861 recalls, and a total of 46 345 screen readings.”
plainn = 39,996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 24- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Cancer detection rates were 6·1 (95% CI 5·4–6·9) per 1000 screened participants in the intervention group, above the lowest acceptable limit for safety, and 5·1 (4·4–5·8) per 1000 in the control group—a ratio of 1·2 (95% CI 1·0–1·5; p=0·052).”
plainn = 996- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
15 more claims
Create a free account to see all 31 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“As shown in Figure 2A, AI agents possess the capacity to process extensive patient data, including medical histories, diagnostic test results, and imaging, thereby aiding healthcare professionals in making more informed and precise diagnostic decisions.62,63,64,65,66,67,68,69”
From A foundational architecture for AI agents in healthcare (2025) · cites this paper as [67]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“Likewise, AI exhibits promising potential in oncology and radiology for automatically identifying and categorising neoplastic lesions observed in thoracic and abdominal imaging, including X-ray, computed tomography (CT) and the more challenging magnetic resonance (MR) imaging.5,6”
From Artificial intelligence and endo-histo-omics: new dimensions of precision endoscopy and histology in inflammatory bowel disease (2024) · cites this paper as [5]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
In the citing paper
“the AI-supported screening was non-inferior and reduced radiologist workload by 44.2% (AI arm, 61,248 reads; control, 109,692) without increasing false-positive rates, and with evidence of earlier cancer detection [30,31].”
From Artificial Intelligence in Clinical Oncology: From Productivity Enhancement to Creative Discovery (2025) · cites this paper as [30]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Self-citationDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Transparency in artificial intelligence
Larsson, S., & Heintz, F. (2020) · Internet Policy Review · doi:10.14763/2020.2.1469 · Cited by 458
Self-citationSechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Freeman, K., Geppert, J., Stinton, C., Todkill, D., Johnson, S., Clarke, A., & Taylor-Phillips, S. (2021) · BMJ · doi:10.1136/bmj.n1872 · Cited by 338
Dembrower, K., Wåhlin, E., Liu, Y., Salim, M., Smith, K., Lindholm, P., Eklund, M., & Strand, F. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30185-0 · Cited by 290
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines
Schünemann, H. J., Lerda, D., Quinn, C., Follmann, M., Alonso-Coello, P., Rossi, P. G., Lebeau, A., Nyström, L., Broeders, M., Ioannidou-Mouzaka, L., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m19-2125 · Cited by 286
Self-citation
Cited by
Items 301–400 of 596
Lu, J., Xu, X., Zhang, Y., Zhuang, K., Fang, T., Zhang, C., Chen, K., Huang, X., & Li, Y. (2025) · Clinical Breast Cancer · doi:10.1016/j.clbc.2025.08.013 · Cited by 3
Basch, C. E., & Basch, C. H. (2025) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.70020 · Cited by 2
Lu, C., Tan, T., Yu, L., MohammadiNasab, P., Zhang, T., Zhang, H., Soryani, M., Mann, R. M., Kozegar, E., & Bao, L. (2025) · Medical Physics · doi:10.1002/mp.70018 · Cited by 3
Radiology AI training and assessment—challenges, innovations, and a path forward
Agarwal, G., Maroo, K., Zomorodian, P., Bhatt, N., Sanli, D., Sharma, A., & Shelmerdine, S. C. (2024) · BJR|Open · doi:10.1093/bjro/tzaf026 · Cited by 6
“32,33 This could either mean fewer breast radiologists will need to be trained for reporting screening studies, but also that those who do wish to under-take this type of work will need to be more vigilant about potential AI pitfalls and when to override these.”
Duijm, L. E. M., van der Veer, E. L., van Beek, H. C., Setz‐Pels, W., Smallenburg, V. V. B., van Bommel, R. M. G., de Coul-Froger, C. L. O., Gielens, M. P. M., van Uden, D. J. P., & Voogd, A. C. (2025) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2025.101526 · Cited by 2
“16,17 Given the rapidly expanding body of evidence and the increasing number of publications on this topic, its implementation is anticipated in the foreseeable future.”
AI-CAD for diagnostic mammography: comparison to radiologists according to different indications
Lee, S. E., Lee, H. S., Park, V. Y., Kim, M. J., Kim, E.-K., & Yoon, J. H. (2025) · European Radiology · doi:10.1007/s00330-025-12232-6 · Cited by 3
Beyond the black box: lessons in explainability from AI in mammography
Ciardiello, A., D'Angelo, A. R., Angelis, L. D., Giagu, S., Sala, E., & Gigante, G. (2026) · Artificial Intelligence Review · doi:10.1007/s10462-026-11518-5 · Cited by 6
Tchokponhoue, G. A. D., & Idri, A. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.110453 · Cited by 2
Sabry, M., Balaha, H. M., Ali, K. M., Mahmoud, A. H., Gondim, D. D., Ghazal, M. A., Soliman, T. H. A., & El-Baz, A. S. (2026) · Cancers · doi:10.3390/cancers18081305 · Cited by 9
Loaiza‐Bonilla, A., Basu, P. S., Lucas, E., Yost, C. D., & Arora, S. (2026) · American Society of Clinical Oncology Educational Book · doi:10.1200/edbk-26-521200 · Cited by 2
Pesapane, F., Caumo, F., Mantellini, P., Irmici, G., Depretto, C., Penco, S., Rotili, A., Trentin, C., Dominelli, V., Corso, G., et al. (2026) · La radiologia medica · doi:10.1007/s11547-026-02217-w · Cited by 3
“A pivotal prospective trial in this domain MASAI randomized non-inferiority trial [38], the first large RCT to evaluate AI in a national breast screening program.”
InfluentialThe role of artificial intelligence in cancer epidemiology: Challenges and opportunities
Zhao, S., Yu, P., Xu, R., & Li, S. (2026) · Intelligent Oncology · doi:10.1016/j.intonc.2026.100070 · Cited by 3
The role of artificial intelligence in precision medicine for breast cancer
Hu, J.-J., Ding, Z.-L., & Yang, Z. (2026) · Discover Oncology · doi:10.1007/s12672-026-05550-8 · Cited by 3
“The results showed that the AI-assisted group increased the BC detection rate by 20% without increasing the false-positive rate, while significantly reducing the radiologists’ workload by 44% (NCT04838756, 2021-04-12) [92].”
Advancing cancer detection and treatment using longitudinal routine clinical data
Liu, F., Wang, K., Xu, H., Tang, C., Shen, X., Wang, M., Yang, L., Yang, L., Liu, L., Hu, C., et al. (2026) · Cell · doi:10.1016/j.cell.2026.07.009 · Cited by 4
Inteligencia artificial y lenguaje médico (y IV)
(2024) · Revista Española de Cardiología · doi:10.1016/j.recesp.2023.10.014 · Cited by 2
AI lesion risk score at different exposure settings
Tingberg, A., Dahlblom, V., Bakić, P. R., Schurz, H., Strand, F., Zackrisson, S., & Dustler, M. (2024) · International Workshop on Breast Imaging (IWBI) · doi:10.1117/12.3026976 · Cited by 2
Gerdes, A., Fasterholdt, I., & Rasmussen, B. S. (2024) · Ugeskrift for Læger · doi:10.61409/v09230600 · Cited by 3
Klinisches Denken, ärztliche Kunst und Artificial Intelligence
Bassetti, S., Hirsch, M. C., & Battegay, E. J. (2024) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/a-2201-5412 · Cited by 3
Artificial Intelligence for Early Breast Cancer Detection
Deendyal, V., Ghazaryan, L., Linden, E. A., Allen, L., & Thaker, N. G. (2025) · AI in Precision Oncology · doi:10.1089/aipo.2024.0051 · Cited by 5
Enhancing Diagnostic Accuracy: The Role of AI in Advanced Radiological Imaging
Kok, C. L., Ho, C. K., Koh, Y. Y., Thanh, N. V., & Teo, T. H. (2024) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon61640.2024.10903067 · Cited by 2
“The study "Artificial Intelligence-Supported Screen Reading versus Standard Double Reading in the MASAI Trial" by Lång et al. (2023) examines whether AI-assisted mammography screening is as effective and safe as the conventional double reading method, focusing on whether AI can achieve similar or…”
Beyond Double Reading: Multiple Deep Learning Models Enhancing Radiologist-led Breast Screening
Cadrin-Chênevert, A. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.250125 · Cited by 2
Effect of Fee Removal on the Use of Digital Breast Tomosynthesis to Minimize Health Care Disparities
Capiro, N. M., Khadka, P., Sayre, J., Sadigh, G., & Hoyt, A. C. (2025) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2025.06.022 · Cited by 3
Examining the role of AI in cancer imaging through the lens of clinical studies
Marcu, L. G., & Marcu, D. C. (2025) · Health and Technology · doi:10.1007/s12553-025-01019-w · Cited by 3
“The first such screening accuracy study (the MASAI trial) aimed to evaluate the clinical safety of an AI-based screen reading mammography protocol versus standard screen reading by radiologists [4].”
Tejani, A. S., & Rajpurkar, P. (2025) · American Journal of Roentgenology · doi:10.2214/ajr.25.34003 · Cited by 2
The Days of Double Reading Are Numbered: AI Matches Human Performance for Mammography Screening
Philpotts, L. E. (2023) · Radiology · doi:10.1148/radiol.232034 · Cited by 2
Artificial intelligence, authorship and publication of case reports
Phillips, N., & REES, M. C. P. (2023) · Case Reports in Women s Health · doi:10.1016/j.crwh.2023.e00553 · Cited by 2
Leveraging Differences in AI and Human “Vision” to Improve Breast Cancer Detection
Mehta, T. S. (2023) · Radiology · doi:10.1148/radiol.232520 · Cited by 3
Hopper, J. L., Nguyen, T. L., Elliott, M. S., Al-Qershi, O. M., Schmidt, D. F., Makalic, E., Li, S., Fox, S., Dowty, J. G., Peña‐Solórzano, C. A., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4764786 · Cited by 3
Precision Omics Initiative Sweden (PROMISE): A New Model for Biomedical ResearchPreprint
mpe, A. K. A., Gudmundsson, S., Walsh, C. P., Lindblad‐Toh, K., Johansson, Å., Clareborn, A., Ameur, A., Edsjö, A., Fioretos, T., Ehrencrona, H., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4992987 · Cited by 2
Comparison of Large Language Models’ Performance on Neurosurgical Board Examination QuestionsPreprint
Andrade, N. S., & Donty, S. V. (2025) · medRxiv · doi:10.1101/2025.02.20.25322623 · Cited by 3
“Lower performance in Neuroradiology reflects current limitations in LLM image processing capabilities [1], though specialized computer vision models already match or exceed human performance in tasks like mammogram interpretation [10] and tumor segmentation [9].”
Strukturierte Früherkennung des sporadischen Mammakarzinoms
Weigel, S., & Katalinic, A. (2024) · Die Radiologie · doi:10.1007/s00117-024-01283-3 · Cited by 2
The Role of Artificial Intelligence in the Sphere of Healthcare
Yurchuk, O. V. (2024) · Medicne pravo · doi:10.25040/medicallaw2024.02.057 · Cited by 2
Integrating artificial intelligence into skin cancer pathways: the opportunities and obstacles
Beresford-Wylie, B., Ashcroft, S., Gaglani, B., Green, A., Smillie, R. W., Tucker, K., Bakhai, A., Esdaile, B. A., & Palamaras, I. (2024) · British Journal of Dermatology · doi:10.1093/bjd/ljae480 · Cited by 1
Mind the gap: AI and barriers to implementation in imaging-based screening
Taib, A. G., Chen, X., Maxwell-Armstrong, C., & Chen, Y. (2025) · Bulletin of The Royal College of Surgeons of England · doi:10.1308/rcsbull.2025.25 · Cited by 1
Künstliche Intelligenz in der Mammadiagnostik
Dietzel, M., Resch, A., & Baltzer, P. (2025) · Die Radiologie · doi:10.1007/s00117-024-01409-7 · Cited by 1
Health Technologies and Impermissible Delays: The Case of Digital Breast Tomosynthesis
Rosenqvist, S., Dustler, M., & Brännmark, J. (2025) · Science and Engineering Ethics · doi:10.1007/s11948-025-00535-2 · Cited by 1
“Today, mammog - raphy faces similar questions about the use of AI-assisted reading, where special - ized software complements the role of human readers in examining mammographic images (Lång et al., 2023).”
Verboom, S. D., Mainprize, J. G., Peters, J., Broeders, M. J. M., Yaffe, M. J., & Sechopoulos, I. (2025) · European Radiology · doi:10.1007/s00330-025-11687-x · Cited by 1
Kwon, M.-R., Kim, S. H., Park, G. E., Mun, H. S., Kang, B. J., Kim, Y. T., & Youn, I. (2025) · La radiologia medica · doi:10.1007/s11547-025-02033-8 · Cited by 2
Xiques-Molina, W., Lozada-Martínez, I. D., Moreno, O. F., & Narvaez‐Rojas, A. R. (2025) · Health care science · doi:10.1002/hcs2.70025 · Cited by 1
Koç, U., Karakaş, E., Sezer, E. A., Beşler, M. S., Özkaya, Y. A., Evrimler, Ş., Yalçın, A., Kızıloğlu, H. A., Kesimal, U., Oruç, M., et al. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.240841 · Cited by 34
Gialias, P., Wiberg, M. K., Brehl, A.-K., Bjerner, T., & Gustafsson, H. (2025) · Acta Radiologica · doi:10.1177/02841851251356176 · Cited by 1
Rivera, E. N. A., Maiques, J. M., de Alcântara, R. C., Román, M., Burón, A., Sala, M., & Busto, M. (2025) · Radiología · doi:10.1016/j.rx.2025.501741 · Cited by 1
Kim, E. Y., Park, E. K., Kwon, M.-R., Kim, M., Park, J., Kang, J., Cho, Y., Lee, S. H., Song, M., Kim, K. H., et al. (2025) · Radiology Artificial Intelligence · doi:10.1148/ryai.240804 · Cited by 2
Seliverstov, P. V., Шаповалов, В. В., Kravchuk, Y. A., Salikova, S. P., Kupov, S., Seliverstova, T., Zadorozhnaya, E., Mikeladze, N., & Kormschikova, K. (2025) · Molekulyarnaya Meditsina (Molecular medicine) · doi:10.29296/24999490-2025-05-08 · Cited by 3
Song, J., Gao, Y., Liu, W., Sun, X., Chen, C., & Wu, X. (2025) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2025.11.003 · Cited by 2
Goron, G. M., & Cherecheș, R. M. (2025) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2025-0219 · Cited by 1
Nitrosi, A., Rossi, P. G., Verzellesi, L., Creola, M., Campari, C., Vacondio, R., Coriani, C., Iotti, V., Pattacini, P., Besutti, G., et al. (2025) · La radiologia medica · doi:10.1007/s11547-025-02154-0 · Cited by 3
Kim, J. Y., Kim, J. J., Lee, H. J., Hwangbo, L., Song, Y. S., Lee, J. W., Lee, N. K., Hong, S. B., & Kim, S. (2025) · La radiologia medica · doi:10.1007/s11547-025-02161-1 · Cited by 1
Künstliche Intelligenz: Chancen und Grenzen
Clusmann, J., Schneider, C. V., Foersch, S., Truhn, D., & Kather, J. N. (2025) · Forum · doi:10.1007/s12312-025-01520-3 · Cited by 1
A Debiasing Technique for Place-based Algorithmic Patrol Management
Einarsson, A., Oestmo, S., Wollman, L., Purves, D., & Jenkins, R. (2025) · Criminal Justice Ethics · doi:10.1080/0731129x.2025.2583681 · Cited by 1
Artificial Intelligence in Breast Cancer Diagnosis and Management
Rao, S. S., & Vidya, R. (2025) · British Journal of Hospital Medicine · doi:10.12968/hmed.2024.0786 · Cited by 1
Women Empowerment and Artificial Intelligence—A Review
Moletsane, R. I., & Zuva, T. (2026) · Lecture notes in networks and systems · doi:10.1007/978-981-96-8895-1_35 · Cited by 1
How much radiologist time can be saved by implementing AI in screen-reading mammograms?
Hovda, T., Holen, Å. S., & Hofvind, S. S. H. (2026) · European Radiology · doi:10.1007/s00330-025-12273-x · Cited by 1
Self-citationReichert, A.-K., Ali, K., Asif, A., & Heilmann, R. M. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2025.1707957 · Cited by 1
Barry, N., Kendrick, J., Molin, K., Li, S., Rowshanfarzad, P., Hassan, G. M., Dowling, J., Ong, J. S. L., Parizel, P. M., Hofman, M. S., et al. (2026) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae36e0 · Cited by 1
Alipanahzadeh, H., Eikefjord, E., & Korbmacher, M. (2026) · Computers in Human Behavior Reports · doi:10.1016/j.chbr.2026.100936 · Cited by 1
Conti, L., Capetti, B., Battaglia, O., Grasso, R., Pesapane, F., Monzani, D., & Pravettoni, G. (2026) · JMIR Medical Informatics · doi:10.2196/78955 · Cited by 7
“A breakthrough point was reached in 2023, when Lång et al [24] published the results of their randomized, controlled mammography screening with artificial intelligence (MASAI) trial, a study investigating an AI-supported screen-reading procedure involving triage of screening examinations to single…”
InfluentialAI for enhancing efficiency and effectiveness of population breast cancer screening
Marinovich, M. L., & Houssami, N. (2026) · The Lancet · doi:10.1016/s0140-6736(26)00092-9 · Cited by 12
Delberghe, F., Li, X., van den Kroonenberg, D. L., Turco, S., Zwart, W., Valvano, G., Jager, A., Postema, A. W., Wijkstra, H., Oddens, J. R., et al. (2026) · European Radiology · doi:10.1007/s00330-026-12323-y · Cited by 1
Grimm, L. J., Dodelzon, K., Bhole, S., Edmonds, C. E., Mullen, L. A., Parikh, J. R., Daly, C., Epling, J. A., Christensen, S. K., & Dontchos, B. N. (2026) · Journal of Breast Imaging · doi:10.1093/jbi/wbaf066 · Cited by 1
Subgroup performance of a commercial digital breast tomosynthesis model for breast cancer detection
Brown-Mulry, B., Isaac, R., Lee, S. H., Seth, A., Min, K., Dapamede, T., Frank Weikai, L. I., Mansuri, A., Woo, M., Fauria-Robinson, C. A., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-70637-3 · Cited by 7
Enhancing Clinical Practice Through Research: Tools for School-Based Speech-Language Pathologists
Reynolds, G., & Cooper, E. (2026) · Language Speech and Hearing Services in Schools · doi:10.1044/2026_lshss-25-00086 · Cited by 1
The role of artificial intelligence (AI) in the early detection of women-specific cancers
Patra, S., Shand, H., & Ghorai, S. (2026) · Discover Medicine · doi:10.1007/s44337-026-00594-9 · Cited by 2
Zambrano, C., Pérez, N., Coimbra, M. T., Baldeon-Calisto, M., Moyano, R. F., Mora, J. R., Camacho, O. E., & Benítez, D. S. (2026) · Life · doi:10.3390/life16040653 · Cited by 1
Zhu, Z., Hu, G., Tan, W., Gao, K., Sun, C. F., Zhou, Z. ‐., Xu, K., Han, W., Shang, M., Qiu, X., et al. (2026) · Nature Cancer · doi:10.1038/s43018-026-01147-w · Cited by 2
“Third, previous breast cancer diagnostic research has demonstrated the potential of AI to replace junior doctors in initial readings, consist ent with broader trends of optimizing clinical workflows through AI integration 52 .”
Moshina, N., Larsen, M., Holen, Å. S., Aase, H. S., Obst-Gleditsch, K., Bartsch, H., Oltedal, L., Chen, Y., & Hofvind, S. S. H. (2026) · Radiology Artificial Intelligence · doi:10.1148/ryai.250988 · Cited by 1
Self-citationAhmed, M. M., Okesanya, O. J., Othman, Z. K., Adebayo, U. O., Oso, T. A., & Lucero‐Prisno, D. E. (2026) · Informatics and Health · doi:10.1016/j.infoh.2026.03.002 · Cited by 1
Tourasse, C., Mesurolle, B., Ottavy, M., Soler-Michel, P., & Taourel, P. (2026) · Radiology Artificial Intelligence · doi:10.1148/ryai.250989 · Cited by 1
Artificial intelligence and transforming cancer care
Reddy, A. M., Kaur, G., Ribaya, V. S. D., Ribaya, E. L. A., Reddy, M. C., Shah, T., Shinde, D. A., & Suri, G. S. (2026) · Discover Oncology · doi:10.1007/s12672-026-05242-3 · Cited by 1
“In breast cancer screening, AI has helped improve detection rates by 29% while reducing radiologist workload by 44%, as demonstrated in the landmark MASAI trial [36].”
Pesapane, F., Latronico, A., Abbate, F., Penco, S., Rotili, A., Dominelli, V., Nicosia, L., Monzani, D., Grasso, R., Pravettoni, G., et al. (2026) · European Radiology · doi:10.1007/s00330-026-12666-6 · Cited by 5
Bothou, Α., Bolou, A., Dinas, K. D., Kyrkou, G. A., Hardy, D., Pappou, P., Varela, P., Margioula‐Siarkou, G., Balafouta, M., & Diamanti, A. (2026) · Healthcare · doi:10.3390/healthcare14121674 · Cited by 1
Lai, C.-Y., Yu, J., Lee, C., Wang, G., Perdana, S. A., Chen, T.-H., & Yeh, T. (2026) · Service Science · doi:10.1287/serv.2025.0067 · Cited by 1
Martiniussen, M. A., Bergan, M. B., Kristiansen, M. U., Hoff, S. R., Koch, H. W., Dahl, F. A., & Hofvind, S. S. H. (2026) · European Radiology · doi:10.1007/s00330-026-12689-z · Cited by 1
Self-citationAI-supported mammography screening: measuring benefit
Chu, Y., Niu, C., & Jin, W. (2026) · The Lancet · doi:10.1016/s0140-6736(26)00699-9 · Cited by 1
Vasileiou, M., Wakefield, V., Dadswell, C., & Edwards, S. J. (2026) · Health Technology Assessment · doi:10.3310/gjse4912 · Cited by 1
Yan, Y., Liu, C., Fu, H., Xu, K., & Xu, H. (2026) · European Radiology · doi:10.1007/s00330-026-12715-0 · Cited by 1
Artificial intelligence in oncology: empowering clinicians for responsible integration
Colliver, E., Parisini, E., Arefaine, B., Banerji, C. R. S., Verghese, G. E., & Grigoriadis, A. E. (2026) · ESMO Real World Data and Digital Oncology · doi:10.1016/j.esmorw.2026.100737 · Cited by 1
Andersen, A. J., Huang, R., & Liu, E. J. (2026) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2026.103495 · Cited by 3
Wulandari, P. I., Gandomkar, Z., Rickard, M., Hooshmand, S., Suleiman, M., & Brennan, P. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113136 · Cited by 1
Lee, S. E., Heo, S., Shin, H. J., & Kim, E. (2026) · European Radiology · doi:10.1007/s00330-026-12793-0 · Cited by 3
Moy, L. P., Vargas, H. A., Gichoya, J. W., Lungren, M. P., Martí‐Bonmatí, L., Hess, C. P., Bredella, M. A., & Schnall, M. D. (2026) · Radiology · doi:10.1148/radiol.253974 · Cited by 2
Large language medicine: defining a new paradigm in human health
Guni, A., Hu, W., Morley, J., Cohen, I. G., Barnaghi, P. M., & Ashrafian, H. (2026) · Frontiers in Science · doi:10.3389/fsci.2026.1810095 · Cited by 3
Morfaki, C. (2026) · Hospitals · doi:10.3390/hospitals3040019 · Cited by 1
Breast-cancer screening gets a boost from AI
(2023) · Nature · doi:10.1038/d41586-023-02526-4 · Cited by 1
Application of Artificial Intelligence in Breast Imaging: Current Landscape and Prospects
Kim, H. J., & Kim, H. H. (2023) · Korean Journal of Family Practice · doi:10.21215/kjfp.2023.13.4.196 · Cited by 2
Künstliche Intelligenz in der Radiologie und Strahlentherapie
Xu, L., Busch, F., Adams, L. C., & Bressem, K. K. (2024) · Die Onkologie · doi:10.1007/s00761-023-01469-9 · Cited by 1
Gastounioti, A., & Kontos, D. (2024) · American Journal of Roentgenology · doi:10.2214/ajr.24.31174 · Cited by 1
Yong, E., Teo, Y. N., McKnoulty, L., Gautam, A., Chaulagain, R., & Yong, K. H. (2024) · Journal of Chitwan Medical College · doi:10.54530/jcmc.1474 · Cited by 1
Morant, R., Gräwingholt, A., Subelack, J., Kuklinski, D., Vogel, J., Blum, M., Eichenberger, A., & Geißler, A. (2024) · Die Radiologie · doi:10.1007/s00117-024-01345-6 · Cited by 2
Grob, M., Jenders, R. A., Rappelsberger, A., & Adlassnig, K.-P. (2024) · Studies in health technology and informatics · doi:10.3233/shti240785 · Cited by 2
“Furthermore, a recent study has found an increase of false-positive findings due to commercially available ML tools in radiology [10], underscoring the need for further research in this area while a first randomized, controlled clinical trial has shown the potential viability of such tools [11].”
BackgroundFrom Promise to Practice: Danaher Gathers Visionaries to Discuss AI-Driven R&D
Lin, F. (2025) · GEN Biotechnology · doi:10.1089/genbio.2025.0003 · Cited by 1
Valbusa, G., Mingo, A. F., & Serra, S. C. (2025) · Clinical and Experimental Rheumatology · doi:10.55563/clinexprheumatol/dknvfz · Cited by 2
Lee, S. E., & Kim, E. (2025) · Journal of Korean Medical Association · doi:10.5124/jkma.25.0045 · Cited by 1
Einführung in die Künstliche Intelligenz
Kather, J. N. (2025) · Springer eBooks · doi:10.1007/978-3-662-71042-5_1 · Cited by 1
Brion, A., Dang, L.-A., Poncelet, É., Ferret, L., Vermersch, M., & Nicolas, L. (2024) · Preprints.org · doi:10.20944/preprints202401.1706.v1
Stop Training Artificial Intelligence Algorithms Now. Start Prospective Trials!
Nishikawa, R. M., & Sumkin, A. (2024) · Journal of Breast Imaging · doi:10.1093/jbi/wbae083 · Cited by 1
Artificial intelligence in breast imaging: From theoretical promise to clinical mirage?
Schiaffino, S., & Girometti, R. (2025) · European Radiology · doi:10.1007/s00330-025-11828-2 · Cited by 1
The Application of Artificial Intelligence in Healthcare Practice: An Umbrella ReviewPreprint
Andersen, A. J., Huang, R., & Liu, E. (2025) · medRxiv · doi:10.1101/2025.10.05.25337356 · Cited by 1
Fahrni, G., & Rotzinger, D. C. (2026) · European Radiology · doi:10.1007/s00330-026-12667-5 · Cited by 1
Mann, R. M., & Teuwen, J. (2023) · American Journal of Roentgenology · doi:10.2214/ajr.23.30359
Metadata
- Authors
- Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A.
- Affiliations
- Lund University (SE)
- Cancer Registry of Norway (NO)
- Corresponding author
- Lång, Kristina
- ORCID
- Venue
- The Lancet Oncology
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 24
- Issue
- 8
- Pages
- 936-944
- ISSN
- 1470-2045 (ISSN-L)
- OpenAlex
- W4385448527
- Semantic Scholar
- abba9a98a0a449e2e14bd6fc8813c996304ddace
- Cited by
- 598
- References
- 30
- Citations by year
- 2026: 197 · 2025: 205 · 2024: 164 · 2023: 31
- FWCI
- 56.30
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- The Lancet Oncology (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- Funders
- Swedish Cancer Society (22 0611FE)
- Skånes universitetssjukhus
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- artificial intelligence, mammography screening, computer-aided detection, double reading, clinical safety, breast cancer detection, recall rate, false positive rate, positive predictive value, non-inferiority, breast cancer screening, breast cancer in situ
- MeSH terms
- Artificial Intelligence, Breast Neoplasms, Female, Humans, Mammography, Mass Screening, Middle Aged, Predictive Value of Tests, Retrospective Studies, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-08, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-08 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.