Real-time diabetic retinopathy screening by deep learning in a multisite national screening programme: a prospective interventional cohort study
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Diabetic retinopathy is a leading cause of preventable blindness, especially in low-income and middle-income countries (LMICs). Deep-learning systems have the potential to enhance diabetic retinopathy screenings in these settings, yet prospective studies assessing their usability and performance are scarce. METHODS: We did a prospective interventional cohort study to evaluate the real-world performance and feasibility of deploying a deep-learning system into the health-care system of Thailand. Patients with diabetes and listed on the national diabetes registry, aged 18 years or older, able to have their fundus photograph taken for at least one eye, and due for screening as per the Thai Ministry of Public Health guidelines were eligible for inclusion. Eligible patients were screened with the deep-learning system at nine primary care sites under Thailand's national diabetic retinopathy screening programme. Patients with a previous diagnosis of diabetic macular oedema, severe non-proliferative diabetic retinopathy, or proliferative diabetic retinopathy; previous laser treatment of the retina or retinal surgery; other non-diabetic retinopathy eye disease requiring referral to an ophthalmologist; or inability to have fundus photograph taken of both eyes for any reason were excluded. Deep-learning system-based interpretations of patient fundus images and referral recommendations were provided in real time. As a safety mechanism, regional retina specialists over-read each image. Performance of the deep-learning system (accuracy, sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) were measured against an adjudicated reference standard, provided by fellowship-trained retina specialists. This study is registered with the Thai national clinical trials registry, TCRT20190902002. FINDINGS: Between Dec 12, 2018, and March 29, 2020, 7940 patients were screened for inclusion. 7651 (96·3%) patients were eligible for study analysis, and 2412 (31·5%) patients were referred for diabetic retinopathy, diabetic macular oedema, ungradable images, or low visual acuity. For vision-threatening diabetic retinopathy, the deep-learning system had an accuracy of 94·7% (95% CI 93·0-96·2), sensitivity of 91·4% (87·1-95·0), and specificity of 95·4% (94·1-96·7). The retina specialist over-readers had an accuracy of 93·5 (91·7-95·0; p=0·17), a sensitivity of 84·8% (79·4-90·0; p=0·024), and specificity of 95·5% (94·1-96·7; p=0·98). The PPV for the deep-learning system was 79·2 (95% CI 73·8-84·3) compared with 75·6 (69·8-81·1) for the over-readers. The NPV for the deep-learning system was 95·5 (92·8-97·9) compared with 92·4 (89·3-95·5) for the over-readers. INTERPRETATION: A deep-learning system can deliver real-time diabetic retinopathy detection capability similar to retina specialists in community-based screening settings. Socioenvironmental factors and workflows must be taken into consideration when implementing a deep-learning system within a large-scale screening programme in LMICs. FUNDING: Google and Rajavithi Hospital, Bangkok, Thailand. TRANSLATION: For the Thai translation of the abstract see Supplementary Materials section.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Autonomous point-of-care, centralized AI or teleophthalmology, and hybrid AI-plus-human grading models should not be ranked universally, because each offers a different balance of immediacy, specialist oversight, infrastructure requirements, and workflow complexity.”
From From validation to public health impact: implementing equitable AI-enabled diabetic retinopathy screening (2026) · cites this paper as [11]
In the citing paper
“Real-time national deployment in Thailand and African clinical validation studies further show that AI performance depends on workflow, image acquisition, and the surrounding screening pathway (9,11).”
From From validation to public health impact: implementing equitable AI-enabled diabetic retinopathy screening (2026) · cites this paper as [11]
In the citing paper
“Autonomous systems can provide same-visit results and reduce dependence on asynchronous grading, whereas centralized models may support multisite quality assurance and specialist oversight; hybrid models retain human review for selected or uncertain cases (8,10,11,14,17,21).”
From From validation to public health impact: implementing equitable AI-enabled diabetic retinopathy screening (2026) · cites this paper as [11]
In the citing paper
“Artificial intelligence (AI) is an accurate screening tool for diabetic retinopathy (DR), the leading cause of blindness among working-aged adults.”
From Referral uptake after diabetic retinopathy screening with artificial intelligence-assisted care pathways: a systematic review and meta-analysis (2026) · cites this paper as [6]
In the citing paper
“Multiple artificial intelligence (AI) algorithms have been developed and validated for DR5–8 screening and it is the most frequently implemented deep learning application in prospective real-world studies9.”
From Referral uptake after diabetic retinopathy screening with artificial intelligence-assisted care pathways: a systematic review and meta-analysis (2026) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saeedi, P., Petersohn, I., Salpea, P., Malanda, B., Karuranga, S., Unwin, N., Colagiuri, S., Guariguata, L., Motala, A. A., Ogurtsova, K., et al. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.107843 · Cited by 10,792
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Self-citationWilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems
(2021) · doi:10.1145/3411764 · Cited by 1,240
Guidelines on Diabetic Eye Care
Wong, T. Y., Sun, J., Kawasaki, R., Ruamviboonsuk, P., Gupta, N., Lansingh, V. C., Maia, M., Mathenge, W., Moreker, S., Muqit, M. M. K., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.04.007 · Cited by 839
Self-citationBeede, E., Baylor, E., Hersch, F., Iurchenko, A., Wilcox, L., Ruamviboonsuk, P., & Vardoulakis, L. M. (2020) · Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376718 · Cited by 614
Self-citationKrause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Self-citationLiu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., Ashrafian, H., Beam, A. L., Chan, A.-W., Collins, G. S., Deeks, A. D. J., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30218-1 · Cited by 555
Research works printed but not linked: 1
- Comparative study of 1-year health outcome related smoking among diabetes patients in primary care. S Saritsiri, Tob Induc Dis. 19A2102021
Cited by
Items 101–200 of 298
Valli, A. D., Tingle, S. J., Kazerouni, S., Kalpana, T. S. R., Karki, B. B., Knight, S. R., Wilson, C. H., & Kourounis, G. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2026.103836 · Cited by 10
Chawla, H., Uhr, J. H., Williams, J. S., Reinoso, M. A., & Weiss, J. S. (2023) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20230406-01 · Cited by 11
Deep learning detection of diabetic retinopathy in Scotland’s diabetic eye screening programme
Fleming, A., Mellor, J., McGurnaghan, S. J., Blackbourn, L. A. K., Goatman, K. A., Styles, C., Storkey, A., McKeigue, P., & Colhoun, H. M. (2023) · British Journal of Ophthalmology · doi:10.1136/bjo-2023-323395 · Cited by 10
Prospective studies on artificial intelligence (AI)-based diabetic retinopathy screening
Nanegrungsunk, O., Ruamviboonsuk, P., & Grzybowski, A. E. (2022) · Annals of Translational Medicine · doi:10.21037/atm-2022-71 · Cited by 10
Self-citationValidation is not enough: Longitudinal evidence of post-deployment fragility in clinical AI systems
Kopanitsa, G. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001534 · Cited by 9
“Prospective program + deployment analysis [43,44] Specialist grading days-weeks, pro-grammatic outcomes months .”
Tseng, R. M. W. W., Ong, L. C., Goh, J. H. L., Chen, Y., Chen, T., Lum, E., & Tham, Y.-C. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02358-2 · Cited by 9
Chotcomwongse, P., Ruamviboonsuk, P., Karavapitayakul, C., Thongthong, K., Amornpetchsathaporn, A., Chainakul, M., Triprachanath, M., Lerdpanyawattananukul, E., Arjkongharn, N., Ruamviboonsuk, V., et al. (2025) · Ophthalmology and Therapy · doi:10.1007/s40123-024-01086-8 · Cited by 9
“Artificial intelligence (AI), with its robust diagnostic accuracy for DR screening [5], can be applied and has shown benefits in real-world, resource-constrained settings [6].”
InfluentialSelf-citationCasazza, M., Bolz, M., & Huemer, J. C. (2025) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-025-01081-z · Cited by 9
Type 2 Diabetes Detection Using a Bio-inspired Machine Learning Approach
Gupta, P., Singh, J., Sharma, P., Kumar, V., Sharma, M., & Singh, R. P. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-5955-5_14 · Cited by 9
Deep learning algorithms for timely diagnosis of retinopathy of prematurity requiring treatment
Shoeibi, N., Ameri, N., Hoseinkhani, M. R., Astaneh, M. R. A., Shariati, M. M., Hosseini, S. M., Abrishami, M., Abrishami, M., Zamani, G., & Heidarzadeh, H. R. (2025) · Eye · doi:10.1038/s41433-025-04096-3 · Cited by 8
Addressing Technical Failures in a Diabetic Retinopathy Screening Program
Brennan, I., Kelly, S., McBride, E., Garrahy, D., Acheson, R. W., Harmon, J., McMahon, S., Keegan, D., Kavanagh, H., & O’Toole, L. (2024) · Clinical ophthalmology · doi:10.2147/opth.s442414 · Cited by 8
Ocular biomarkers: useful incidental findings by deep learning algorithms in fundus photographs
Martin, E., Cook, A. G., Frost, S. M., Turner, A. W., Chen, F. K., McAllister, I. L., Nolde, J. M., & Schlaich, M. P. (2024) · Eye · doi:10.1038/s41433-024-03085-2 · Cited by 8
Wang, Y., Yang, Z., Guo, X., Jin, W., Lin, D., Chen, A., & Zhou, M. (2024) · Eye and Vision · doi:10.1186/s40662-024-00396-z · Cited by 8
Optimal Convolutional Networks for Staging and Detecting of Diabetic Retinopathy
Hidri, M. S., Hidri, A., Alsaif, S. A., Alahmari, M., & Alshehri, E. (2025) · Information · doi:10.3390/info16030221 · Cited by 8
Ran, A. R., Ding, J. L., Tang, Z., Lam, C., Nguyen, T. X., Zhou, J., Zhang, S., Fang, D., Yang, D., Ng, V., et al. (2026) · Diabetes Care · doi:10.2337/dc25-1493 · Cited by 7
Ayoade, O. B., Shahrestani, S. A., & Ruan, C. (2026) · Electronics · doi:10.3390/electronics15020394 · Cited by 8
Deep learning for clinical decision-making and improved healthcare outcome
Kabir, R., Syed, H. Z., Vinnakota, D., Sivasubramanian, M., Hitch, G., Okello, S. A., Sharon-Shivuli-Isigi, Pulikkottil, A. T., Mahmud, I., Dehghani, L., et al. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-19413-9.00004-7 · Cited by 7
Peng, J. M., Abdulla, R., Liu, X., He, F., Xin, X., & Aisa, H. A. (2024) · Nutrients · doi:10.3390/nu16172944 · Cited by 7
da Silva, W. M., Cazella, S. C., & Rech, R. S. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2025.105933 · Cited by 7
Casey, A., Ansari, S., Nakisa, B., Kelly, B., Brown, P., Cooper, P., Muhammad, I., Livingstone, S., Reddy, S., & Mäkinen, V. (2023) · JMIR AI · doi:10.2196/42313 · Cited by 7
Toward safer ophthalmic artificial intelligence via distributed validation on real-world data
Nath, S., Rahimy, E., Kras, A., & Korot, E. (2023) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000986 · Cited by 7
Zhang, D., Liu, M., Chen, F., Lu, Q., & Zhao, Y. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106134 · Cited by 7
Perspectives: Comparison of deep learning segmentation models on biophysical and biomedical data
Bryan, J. S., Pessoa, P., Tavakoli, M., & Pressé, S. (2025) · Biophysical Journal · doi:10.1016/j.bpj.2025.03.023 · Cited by 7
Simpson, A., & Ramagopalan, S. V. (2022) · Journal of Comparative Effectiveness Research · doi:10.2217/cer-2022-0145 · Cited by 7
Li, Z., Li, J., Zhong, J., Qu, C., Du, M., Tian, H., Xu, H., Hao, F., & Huang, L. (2024) · Scientific Reports · doi:10.1038/s41598-024-80797-1 · Cited by 6
Goh, J. H. L., Lei, X., Chee, M.-L., Qian, Y., Yu, M., Rim, T. H., Nusinovici, S., Chen, D. Z., Koh, K. H., Yew, S. M. E., et al. (2025) · Ophthalmology Science · doi:10.1016/j.xops.2025.100837 · Cited by 6
Self-citationDaley, J. R., Wang, X., Ngo, N. S., Khoo, C. L., Heydon, P., Liew, G., Vallayutham, V., Kongbrailatpam, T., Osuagwu, U. L., Andric, M., et al. (2025) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.14560 · Cited by 6
Teleophthalmology in Retinal Diseases
El-Badawi, K., Goodchild, C., Drukarch, H., & Salvatore, S. (2024) · Biomedical engineering · doi:10.5772/intechopen.1004757 · Cited by 6
Artificial intelligence in healthcare: a perspective from Google
Lehmann, L. S., Natarajan, V., & Peng, L. H. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15688-5.00037-1 · Cited by 6
Self-citationDistribution, Recognition, and Just Medical AI
Daus, Z. (2025) · Philosophy & Technology · doi:10.1007/s13347-025-00842-3 · Cited by 5
Yudistira, Y., Hendrawan, K. A., Andayani, A., Suryathi, N. M. A., Ernawati, T., Gunawan, A. C. V., & Daradila, N. P. K. M. (2025) · Turkish Journal of Ophthalmology · doi:10.4274/tjo.galenos.2025.32916 · Cited by 5
Directed Ordinal Diffusion Regularization for Progression-Aware Diabetic Retinopathy Grading
Chen, H., Jia, J., Li, R., Yang, C., Li, W., Pang, X., Chen, Y., Wang, H., Bu, J., & Wu, L. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-38172-9_20 · Cited by 5
Nigam, A., Sun, J., Subhash, V., Aiello, L. P., Silva, P. S., Huang, Y., & Luo, G. (2024) · Studies in computational intelligence · doi:10.1007/978-3-031-63592-2_9 · Cited by 5
Kuruba, C., & Gopalan, N. P. (2025) · Neural Computing and Applications · doi:10.1007/s00521-025-11355-7 · Cited by 5
Solving data quality issues of fundus images in real-world settings by ophthalmic AI
Li, Z., & Chen, W. (2023) · Cell Reports Medicine · doi:10.1016/j.xcrm.2023.100951 · Cited by 5
BranchFusionNet: An energy-efficient lightweight framework for superior retinal vessel segmentation
Qin, J., Qin, Z., & Xiao, P. (2024) · Peer-to-Peer Networking and Applications · doi:10.1007/s12083-024-01738-3 · Cited by 5
What We Want to Publish at NEJM AI
Manrai, A. K., Beam, A. L., & Kohane, I. S. (2024) · NEJM AI · doi:10.1056/aie2300304 · Cited by 5
Sivayamini, L., Venkatesh, C., Chalivendula, B., Annadanam, G. H. P., Kanaganipalli, A., & Mogili, C. S. (2024) · International Conference on Recent Innovation in Smart and Sustainable Technology (ICRISST) · doi:10.1109/icrisst59181.2024.10921992 · Cited by 4
Customizing AI ‐based screening with real‐world data: Practical insights from diabetic retinopathy
Poschkamp, B., Kantz, L., Augstein, P., Tayar, A., Kaderali, L., Busch, M., Bohl, B., Paúl, S., Lüdtke, L., Bründer, M., et al. (2025) · Acta Ophthalmologica · doi:10.1111/aos.17591 · Cited by 4
Lee, J. T., Hsu, S. H., Li, V. C.-S., Anindya, K., Chen, M. M., Wang, C. I., Shen, T. K.-B., Liu, V. T. N., Chen, H.-H., & Atun, R. A. (2025) · PLOS Digital Health · doi:10.1371/journal.pdig.0000951 · Cited by 4
A Real-World Comparison of Three Deep Learning Systems for Diabetic Retinopathy in Remote Australia
Drinkwater, J. J., Li, Q., Woods, K., Douglas, E., Chia, M. A., Zhou, Y., Bartnik, S., Shah, Y., Shah, V., Keane, P. A., et al. (2025) · Diabetology · doi:10.3390/diabetology6120146 · Cited by 4
Shen, Y., Chen, Q., He, X., Agrawal, R. V., Grzybowski, A. E., Jin, K., & Ye, X. (2026) · Ophthalmology and Therapy · doi:10.1007/s40123-026-01316-1 · Cited by 4
Artificial intelligence in retinal care: transforming the doctor-patient partnership
Hanhart, J., Celi, L. A., Blumenthal, E. Z., Almog, R., & Behar, J. A. (2026) · International Journal of Retina and Vitreous · doi:10.1186/s40942-026-00837-y · Cited by 4
Malik, M. H., Wan, Z., & Ding, D.-W. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110228 · Cited by 4
Digital Health Technologies for Chronic Disease Prevention: A Narrative Review
Almohammadi, A. A. (2026) · Current Medical Issues · doi:10.4103/cmi.cmi_227_25 · Cited by 4
Umanandhini, D., Devi, M. S., & Devi, S. S. (2023) · International Conference on Evolutionary Algorithms and Soft Computing Techniques (EASCT) · doi:10.1109/easct59475.2023.10393224 · Cited by 4
A Comprehensive Overview of Telemedicine
Heston, T. F., & Doarn, C. R. (2024) · Biomedical engineering · doi:10.5772/intechopen.1002138 · Cited by 4
MAFNet: A novel adaptive multi-scale model for fine-grained grading of diabetic retinopathy
Sun, L., Peng, Q., Xiao, X., Liu, J., Li, Y., Shu, D., & Xue, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-17158-z · Cited by 4
Leigh, J. A., Sherrington, A., Barber, A. R. J., Turner, A. W., Kidd, M., Powell, J., & Pope, C. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02616-3 · Cited by 3
“Detailed risk of bias assessments are presented in Supplementary Tables 5 and 6.”
Decision Assist During Mechanical Ventilation
Hotz, J. C., Chang, D., Khemani, R. G., & Newth, C. J. L. (2025) · Respiratory Care · doi:10.1177/19433654251384240 · Cited by 3
Rogers, M., Kaggwa, F., Arunga, S., & Wasswa, W. (2025) · Cureus Journal of Computer Science. · doi:10.7759/s44389-025-07263-5 · Cited by 3
Medical Artificial Intelligence Research Landscape in Thailand: A Bibliometric Analysis
Kongthon, A. (2023) · International Joint Symposium on Artificial Intelligence and Natural Language Processing (iSAI-NLP) · doi:10.1109/isai-nlp60301.2023.10354993 · Cited by 3
Lamrani, M., Moghadas, M., Kalia, Y. N., & Santer, V. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_19 · Cited by 3
Roubelat, F.-P., Soler, V. J., Varenne, F., & Gualino, V. (2024) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2024.104130 · Cited by 3
АВТОМАТИЗИРОВАННАЯ ДИАГНОСТИКА ДИАБЕТИЧЕСКОЙ РЕТИНОПАТИИ (обзор)
Арифовна, Б. Ф., Kangilbaeva, G., Makhkamovna, U. F., Набиева, И. Ф., & Журабекова, А. З. (2024) · Advanced Ophthalmology · doi:10.57231/j.ao.2024.8.2.002 · Cited by 3
Yue, J., Luo, L., Guo, M., & Xu, C. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.128816 · Cited by 3
Artificial Intelligence, Cybersight Detection of Diabetic Retinopathy in the Elderly in Vietnam
Hai, H. L. T., Pham, T. V., Mai, T. Q., Duc, M. D., Viet, Q. N., & Tuan, T. T. (2024) · Journal of Current Science and Technology · doi:10.59796/jcst.v15n1.2025.80 · Cited by 3
Closing Gaps in Diabetic Retinopathy Screening in India Using a Deep Learning System
Ong, S. S. Y., & Varghese, J. S. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.0991 · Cited by 3
A Review on Machine Learning Methods in Diabetic Retinopathy Detection
Alaeddini, Z. (2021) · Journal of Ophthalmic and Optometric Sciences · doi:10.22037/joos.v5i1.39216 · Cited by 3
The Human Element: Ethical Guardrails for AI in Modern Medicine
Ferguson, J. (2025) · The American Journal of Cosmetic Surgery · doi:10.1177/07488068251359686 · Cited by 3
Ten years later: how is AI impacting retina care today?
Kuo, D. C., Pajić, M., & Hadziahmetovic, M. (2025) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000001167 · Cited by 2
Onyeze, N. S., Sartawi, S., & Nayyer, Z. (2025) · Cureus · doi:10.7759/cureus.96554 · Cited by 2
Rahim, S. S., Walambe, R. A., Kotecha, K. V., & Palade, V. (2025) · Artificial Intelligence Research and Applications · doi:10.20508/jf9v8s55 · Cited by 2
Fortino, L., Vita, S. D., Esposito, M., & Esposito, C. (2025) · IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE) · doi:10.1109/metroxraine66377.2025.11340268 · Cited by 2
Artificial intelligence for diabetes complications: Detection, prediction, and clinical management
Yu, S., Guan, Z., Wang, S., Mao, H., Sheng, B., Jia, W., & Li, H. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100133 · Cited by 2
Consumer Understanding of Skin Concerns With an AI-Powered Informational Tool
Sayres, R., Jain, A., Venkatraman, M., Singh, P. K., Liu, Y., Winter, S. R., Schaekermann, M., Loh, A., Verma, S., Matias, Y., et al. (2026) · JAMA Dermatology · doi:10.1001/jamadermatol.2026.0597 · Cited by 2
Self-citationDiabetic Retinopathy Detection: AI Models and Approaches
Madi, M. M. M., Clarke-Farr, P. C., & Bester, D. J. (2026) · Journal of Ophthalmology · doi:10.1155/joph/8857887 · Cited by 2
Cost-effectiveness analysis of human–AI collaboration in disease screening
Wang, Y., Han, X., Hu, W., Zhou, K., Liu, C., Zhang, J., Zhu, Z., Joseph, S., Yin, Q., Luo, L., et al. (2026) · Nature Health · doi:10.1038/s44360-026-00142-w · Cited by 2
Sociotechnical Challenges of Machine Learning in Healthcare and Social Welfare
Reinmund, T., Kunze, L., & Jirotka, M. D. (2026) · ACM Interactive Health Conference · doi:10.1145/3786579.3804917 · Cited by 2
Fosset, M., Pensier, J., Jung, B., Siddiqi, A., Mamdani, M. M., & Celi, L. A. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001621 · Cited by 2
Diabetic retinopathy and choroidopathy: Pathophysiology, imaging findings, and treatment updates
Silpa‐archa, S., Tadarati, M., Chotcomwongse, P., & Ruamviboonsuk, P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15583-3.00016-0 · Cited by 2
Self-citationDR10K: Transfer Learning Using Weak Labels for Grading Diabetic Retinopathy on DR10K Dataset
ElHabebe, M., Elkordi, S., Eldin, A. G., Adly, N., Torki, M., Elmassry, A., & Ahmed, I. S. H. (2024) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv57701.2024.00757 · Cited by 2
Islam, N., Osman, A. R., & Godfrey, L. (2025) · JMA Journal · doi:10.31662/jmaj.2025-0175 · Cited by 2
Using artificial intelligence in diabetic retinopathy
Mohan, S., Gaur, R., & Raman, R. (2022) · IHOPE Journal of Ophthalmology · doi:10.25259/ihopejo_20_2022 · Cited by 2
Self-citationChawla, H., Hicks, C. P., Assi, L., Epling, J. P., Al-Dujaili, L. J., & Weiss, J. S. (2023) · JFO Open Ophthalmology · doi:10.1016/j.jfop.2023.100037 · Cited by 2
Artificial intelligence for diabetic retinopathy screening: beyond diagnostic accuracy
Malerbi, F. K. (2022) · Annals of Translational Medicine · doi:10.21037/atm-22-4756 · Cited by 2
Dave, D., & Sawhney, G. (2023) · doi:10.36227/techrxiv.24601953.v1 · Cited by 2
dos Reis, M. A. (2023) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 2
Brant, R., Nakayama, L. F., de Oliveira, T. V. F., de Oliveira, J. A. E., Ribeiro, L. Z., Richter, G. D., Rodacki, R., & Penha, F. M. (2024) · International Journal of Retina and Vitreous · doi:10.1186/s40942-024-00559-z · Cited by 1
Yamamoto, K., Ihana‐Sugiyama, N., Sugiyama, T., Yamaoka, T., Wakui‐Kimura, A., Imai, K., Kuroda, N., Ohsugi, M., Ueki, K., Yamauchi, T., et al. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16164 · Cited by 1
Expanding Vision Services at Federally Qualified Health Centers
Ong, S. S. Y. (2025) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2025.0003 · Cited by 1
A Deep Learning Approach for Detecting Diabetic Retinopathy
Nabil, M. H. H., Hammam, L., Bastawrous, H. A., & Ebrahim, G. A. (2024) · International Conference on Computer and Applications (ICCA) · doi:10.1109/icca62237.2024.10927999 · Cited by 1
Is Uncertainty Quantification a Viable Alternative to Learned Deferral?
Wundram, A. M., & Baumgartner, C. F. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-06593-3_4 · Cited by 1
李银娟 (2025) · Journal of Clinical Personalized Medicine · doi:10.12677/jcpm.2026.51048 · Cited by 1
Vitreoretinal disease detection using artificial intelligence: a systematic review and meta-analysis
Heidari, Z., Mirghorbani, M., Abounoori, M., Ebrahimibesheli, K., Tabarestani, M., Khabazkhoob, M., Yousefi, S., & Modjtahedi, B. S. (2026) · International Ophthalmology · doi:10.1007/s10792-026-03960-9 · Cited by 1
Deng, G., & Chengshi, W. (2026) · Science Progress · doi:10.1177/00368504261418899 · Cited by 1
Das, T., Jalali, S., Jonas, J., Kawasaki, R., Saw, S., Sivaprasad, S., Tan, A. C. S., & Ruamviboonsuk, P. (2026) · Ophthalmology and Therapy · doi:10.1007/s40123-026-01361-w · Cited by 1
Self-citationLiu, Q., Zhang, P., Meng, L., He, J., & Han, H. (2026) · IEEE Access · doi:10.1109/access.2026.3699584 · Cited by 1
Altobelli, E., Baroni, M. G., Ciancaglini, M., Carpineto, P., & Masedu, F. (2026) · Scientific Reports · doi:10.1038/s41598-026-58158-x · Cited by 1
Chauhan, A., Rana, G. S., Verma, P., Yadav, M., Kumar, L., Kaur, G., Gupta, V., Menon, G., Prabhath, P. M., Vale, L., et al. (2026) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_2774_25 · Cited by 1
Feng, Y., Zhou, S., Xu, J., Qiu, W., Zhang, Q., & Luo, L. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111067 · Cited by 1
Zhu, M., Gou, L., Zhang, C., & Zheng, D. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1912362 · Cited by 2
Autonomous AI for Diabetic Retinopathy Screening: Evidence, Regulation, and Health-System Fit
Mehta, K., Patel, L., & Shah, M. (2026) · Clinical eHealth · doi:10.1016/j.ceh.2026.07.001 · Cited by 1
Xu, Y., Veillard, J. H. M., & Kong, J. D. (2026) · Journal of Medical Internet Research · doi:10.2196/95157 · Cited by 1
Ohaiba, M. M., Arifayan, S. O., Oladimeji, A. O., Ogundipe, A. T., Okobi, O. E., & Okobi, E. K. (2026) · Journal of Advances in Medicine and Medical Research · doi:10.9734/jammr/2026/v38i96189 · Cited by 1
Shalash, F. A., & Alshagrawi, S. S. (2026) · Health Policy and Technology · doi:10.1016/j.hlpt.2026.101303 · Cited by 1
Current Trends in AI and Eye Disease Diagnostics
Cruz, M. J., Limaye, S., & Christopher, M. (2026) · Ophthalmic and Physiological Optics · doi:10.1007/s44402-026-00193-2 · Cited by 1
Jin, K., Zhao, K., Agrawal, R. V., Ying, G., & Grzybowski, A. E. (2026) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2026.101533 · Cited by 1
BAYDİLİ, I., Taşçı, B., Taşçı, G., Doğan, Ş., & Tuncer, T. (2026) · Bioengineering · doi:10.3390/bioengineering13101175 · Cited by 1
Luo, J., Luo, J., Wang, F., Cheng, L., Xu, D., Ye, H., Ye, Z., & Qi, Z. (2026) · AI Evidence-Based Medicine · doi:10.1097/ai9.0000000000000017 · Cited by 1
Metadata
- Authors
- Ruamviboonsuk, P., Tiwari, R., Sayres, R., Nganthavee, V., Hemarat, K., Kongprayoon, A., Raman, R., Levinstein, B., Liu, Y., Schaekermann, M., Lee, R., Virmani, S., Widner, K., Chambers, J., Hersch, F., Peng, L., & Webster, D. R.
- Affiliations
- Rajavithi Hospital (TH)
- Google (United States) (US)
- Vajira Hospital (TH)
- Nakornping Hospital (TH)
- Sankara Nethralaya (IN)
- Noom (United States) (US)
- Amazon (United States) (US)
- Imperial College London (GB)
- Corresponding author
- Sayres, Rory
- Venue
- The Lancet Digital Health
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 4
- Issue
- 4
- Pages
- e235-e244
- ISSN
- 2589-7500 (ISSN-L)
- OpenAlex
- W4220926288
- Semantic Scholar
- e061c0a07d81784156e0943533d224a8222e2100
- Cited by
- 250
- References
- 32
- Citations by year
- 2026: 59 · 2025: 60 · 2024: 60 · 2023: 57 · 2022: 13
- FWCI
- 27.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Locations
- The Lancet Digital Health (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- Google Inc
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- diabetic retinopathy screening, deep learning, fundus images, diabetic macular edema, primary care, national screening program, low- and middle-income countries, Thailand, diagnostic accuracy, referral guidelines, field deployment, avoidable blindness, diabetes complications
- MeSH terms
- Deep Learning, Diabetes Mellitus, Diabetic Retinopathy, Humans, Macular Edema, Prospective Studies, Thailand, Cohort Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.