Inhomogeneity of human vertebral cancellous bone: systematic density and structure patterns inside the vertebral body
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
In the spine, cancellous bone quality is usually assessed for the whole vertebral body in a transverse central slice. Correct identification and assessment of the weakest parts of the cancellous bone may lead to better prediction of fracture risk. The density and structural parameters were systematically investigated inside the thoracic (T-9), thoracolumbar (T12-L1), and lumbar (L-4) vertebral bodies of nine subjects. On both sides of the median sagittal plane, anterior and posterior 8.2 mm vertical cores were harvested in the thoracic vertebra. In the thoracolumbar and lumbar vertebrae, external samples were also cored. Peripheral quantitative computed tomographic (pQCT) density analysis of the 136 cores was performed at four different levels, from the lower to the upper endplate. The relatively thin slice thickness (300 microm) and small pixel size (70 microm x 70 microm) was considered sufficient to investigate the structural parameters on the four transverse slices and in the sagittal and coronal planes (total of 816 images). Using a constant threshold a binary image was generated and the morphometric data were extracted. The binary image was further skeletonized and classical strut analysis was performed. Cancellous bone density was 20% higher in the posterior cores than in the anterior and external cores. Moreover, clear vertical inhomogeneity was noted because the lowest half of the vertebral body presented lower density than the upper half (differences ranging from 25% to 15%). All structural parameters were strongly dependent on the location of the measurement. Structural differences between anterior, posterior, and external areas were mild and followed the density patterns. On the other hand, vertical inhomogeneity of the structural parameters was important. For example, in the thoracolumbar and lumbar vertebrae, the numbers of nodes or node-to-node struts were almost twofold higher in the inferior half than in the superior half (p < 0.01), whereas trabecular thickness and number of free-ends presented a center/close-to-endplate structural pattern, with central trabeculae being 15% thicker (p < 0.05) and presenting 30% fewer free-ends (p < 0.01) than the close-to-endplate ones. Variability of density and structural parameters was high and a substantial part of this variability could be explained by the place inside the vertebral body where the measurement was made. The weak part was not in the center of the body but in its upper half where the lower density did not seem to be compensated by a higher structural architecture. Further clinical investigation could enhance fracture prediction by tracking and focusing on the weakest part of the vertebral body.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, in the vertebrae, variations in density and architecture have been observed along the superior–inferior and posterior–anterior directions (87).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [87]
Citations
Cites
Parfitt, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. A., Malluche, H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650020617 · Cited by 5,016
Bone Histomorphometry : Standardization of Nomenclature, Symbols, and Units
PARFITT, A. M., Drezner, M. K., Glorieux, F. H., Kanis, J. А., Malluche, H. H., Meunier, P. J., Ott, S. M., & Recker, R. R. (1987) · Journal of Bone and Mineral Research · Cited by 3,258
Noninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Variations in strength of vertebrae with age and their relation to osteoporosis
Bell, G. H., Dunbar, O., Beck, J. S., & Gibb, A. (1967) · Calcified Tissue Research · doi:10.1007/bf02008077 · Cited by 347
Age-related changes in vertebral trabecular bone architecture—assessed by a new method
Mosekilde, L. (1988) · Bone · doi:10.1016/8756-3282(88)90038-5 · Cited by 314
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300
Biologically meaningful determinants of the in vitro strength of lumbar vertebrae
Vesterby, A., Mosekilde, L., Gundersen, H. J. G., Melsen, F., Mosekilde, L., Holme, K., & Sørensen, S. (1991) · Bone · doi:10.1016/8756-3282(91)90044-j · Cited by 233
Ritzel, H., Amling, M., Pösl, M., Hahn, M., & Delling, G. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.89 · Cited by 220
Implications of architecture for the pathogenesis and prevention of vertebral fracture
PARFITT, A. (1992) · Bone · doi:10.1016/8756-3282(92)90196-4 · Cited by 202
Research works printed but not linked: 1
- Edwards, 1986, Variation of the density in the vertebral body measured by quantitative computed tomography, Trans Orthop Res Soc, 11, 205
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“For example, in the vertebrae, variations in density and architecture have been observed along the superior–inferior and posterior– anterior directions (87).”
Bone mechanical properties and changes with osteoporosis
Osterhoff, G., Morgan, E. F., Shefelbine, S. J., Karim, L., McNamara, L. M., & Augat, P. (2016) · Injury · doi:10.1016/s0020-1383(16)47003-8 · Cited by 557
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
“differences [9,13] and densitometric inhomogeneities [14,15] on vertebral strength.”
BackgroundBanse, X., Sims, T. J., & Bailey, A. J. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.9.1621 · Cited by 267
“Our sampling strategy was rigorous and proved its sensitivity to the within-subject variations in the structure or density.((25)) The end-cap technique was used for measurement of properties of vertebral cancellous bone because it was designed specially to eliminate end artifacts thus allowing a precise measurement of…”
BackgroundMethodInfluentialSelf-citationRegional variation in vertebral bone morphology and its contribution to vertebral fracture strength
Hulme, P. A., Boyd, S. K., & Ferguson, S. J. (2007) · Bone · doi:10.1016/j.bone.2007.08.019 · Cited by 239
Zhao, F.-D., Pollintine, P., Hole, B. D., Adams, M. A., & Dolan, P. (2009) · Bone · doi:10.1016/j.bone.2008.10.048 · Cited by 201
Morphology of the human vertebral endplate
Rodriguez, A. G., Rodríguez‐Soto, A. E., Burghardt, A. J., Berven, S., Majumdar, S., & Lotz, J. C. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21513 · Cited by 169
Oxland, T. R. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.035 · Cited by 167
Adams, M. A., Pollintine, P., Tobias, J. H., Wakley, G. K., & Dolan, P. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060609 · Cited by 165
Vertebral Osteoporosis and Trabecular Bone Quality
Donnell, P. M., McHugh, P. E., & Mahoney, D. O. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9239-9 · Cited by 165
The vertebral fracture cascade in osteoporosis: a review of aetiopathogenesis
Briggs, A. M., Greig, A. M., & Wark, J. D. (2007) · Osteoporosis International · doi:10.1007/s00198-006-0304-x · Cited by 162
“Similarly, studies utilising QCT report lower volumetric bone density in central and anterior regions of vertebral bodies [33, 34], while studies using DXA report lower BMD anteriorly and centrally compared with measures of gross bone mass [35, 36].”
ResultRole of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical Behavior
Fields, A. J., Eswaran, S. K., Jekir, M. G., & Keaveny, T. M. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090317 · Cited by 145
Regional variations of vertebral trabecular bone microstructure with age and gender
Chen, H., Shoumura, S., Emura, S., & Bunai, Y. (2008) · Osteoporosis International · doi:10.1007/s00198-008-0593-3 · Cited by 136
“Low energy compression fractures can occur in the anterior or posterosuperior regions of the vertebra, but rarely in the inferoposterior region [48, 49].”
BackgroundMethodThe importance of the endplate for interbody cages in the lumbar spine
Polikeit, A., Ferguson, S. J., Nolte, L. P., & Orr, T. E. (2003) · European Spine Journal · doi:10.1007/s00586-003-0556-5 · Cited by 122
A review of anatomical and mechanical factors affecting vertebral body integrity
Briggs, A. M., Greig, A. M., Wark, J. D., Fazzalari, N. L., & Bennell, K. L. (2004) · International Journal of Medical Sciences · doi:10.7150/ijms.1.170 · Cited by 118
“During aging, there is a non-uniform loss of bone within the vertebral body, resulting in trabecular bone density becoming non-homogenous throughout the centrum [2, 3, 56].”
BackgroundWegrzyn, J., Roux, J.-P., ARLOT, M. E., Boutroy, S., Vilayphiou, N., Guyen, O., Delmas, P. D., Chapurlat, R. D., & Bouxsein, M. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.164 · Cited by 112
Zone-dependent changes in human vertebral trabecular bone: clinical implications
Thomsen, J. S., Ebbesen, E. N., & Mosekilde, L. (2002) · Bone · doi:10.1016/s8756-3282(02)00686-5 · Cited by 91
Biomechanics of vertebral compression fractures and clinical application
Adams, M. A., & Dolan, P. (2011) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-011-1355-9 · Cited by 92
“Likewise, trabeculae are denser in the inferior half compared with the superior half [6, 7 ] (Fig. 2, lower) possibly because they are reinforced by trabecular arcades from the pedicles.”
BackgroundLee, J. H., Jeon, D.-W., Lee, S.-J., Chang, B., & Lee, C. (2010) · Spine · doi:10.1097/brs.0b013e3181c4baf5 · Cited by 87
Cross-link profile of bone collagen correlates with structural organization of trabeculae
Banse, X., Devogelaer, J. P., Lafosse, A., Sims, T. J., Grynpas, M. D., & Bailey, A. J. (2002) · Bone · doi:10.1016/s8756-3282(02)00800-1 · Cited by 81
Self-citationPeng, W., Liu, Y., Jiang, X., Dong, X., Jun, J., Baur, D. A., Xu, J., Pan, H., & Xu, X. (2019) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.b1800622 · Cited by 80
Mechanical improvements to reinforced porous silk scaffolds
Gil, E. S., Kluge, J. A., Rockwood, D. N., Rajkhowa, R., Wang, L., Wang, X., & Kaplan, D. L. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33158 · Cited by 73
Kim, D., Hunt, C. A., Zauel, R. R., Fyhrie, D. P., & Yeni, Y. N. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9363-1 · Cited by 67
Lenchik, L., Shi, R., Register, T. C., Beck, S. R., Langefeld, C. D., & Carr, J. J. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200401000-00023 · Cited by 60
“The observed difference in BMD in the thoracic and lumbar spine may represent geometric, physical, or biomechanical differences inherent in the trabecular bone at the 2 sites.(32) The improved spatial resolution through the use of a thinner slice collimation may play a role.”
BackgroundLi, G., Zheng, X., Gu, H., Li, X., Yuan, W. A., Chang, S., Fan, J., Calimente, H., & Hu, J. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25351 · Cited by 59
Wu, Y. C., Kuo, C. N., Shie, M., Su, Y. L., Wei, L.-J., Chen, S. Y., & Huang, J. C. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.08.027 · Cited by 57
Arentsen, L., Yagi, M., Takahashi, Y., Bolan, P. J., White, M., Yee, D., & Hui, S. K. (2014) · Bone · doi:10.1016/j.bone.2014.11.002 · Cited by 56
“Cancellous bone of a single vertebral body is heterogeneous, with density varying by as much as 20% [1].”
Ishikawa, K., Toyone, T., Shirahata, T., Kudo, Y., Matsuoka, A., Maruyama, H., Hayakawa, C., Tani, S., Sekimizu, M., Tsuchiya, K., et al. (2018) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000000703 · Cited by 54
Techniques for the Investigation of Age-Related Bone Loss and Osteoporosis in Archaeological Bone
Brickley, M. B., & Agarwal, S. C. (2003) · Springer eBooks · doi:10.1007/978-1-4419-8891-1_10 · Cited by 53
Heritability of lumbar trabecular bone mechanical properties in baboons
Havill, L. M., Allen, M. R., Bredbenner, T. L., Burr, D. B., Nicolella, D. P., Turner, C. H., Warren, D. M., & Mahaney, M. C. (2009) · Bone · doi:10.1016/j.bone.2009.11.002 · Cited by 52
“Considerable heterogeneity in vertebral body trabecular bone microstructure has been documented in lumbar vertebrae of humans [38,39].”
Human Evolution and Osteoporosis-Related Spinal Fractures
Cotter, M. M., Loomis, D. A., Simpson, S. W., Latimer, B., & Hernandez, C. J. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026658 · Cited by 50
Fajardo, R. J., Hernandez, E., & O’Connor, P. M. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00749.x · Cited by 49
Vertebral body integrity: a review of various anatomical factors involved in the lumbar region
Prakash, Prabhu, L. V., Saralaya, V., Pai, M. M., Ranade, A. V., Singh, G., & Madhyastha, S. P. (2007) · Osteoporosis International · doi:10.1007/s00198-007-0373-5 · Cited by 49
Hussein, A. I., & Morgan, E. F. (2012) · Osteoporosis International · doi:10.1007/s00198-012-2039-1 · Cited by 44
Wang, Y., Owoc, J. S., Boyd, S. K., Videman, T., & Battié, M. C. (2013) · Bone · doi:10.1016/j.bone.2013.06.022 · Cited by 44
Landham, P. R., Baker-Rand, H. L. A., Gilbert, S. J., Pollintine, P., Annesley-Williams, D. J., Adams, M. A., & Dolan, P. (2014) · The Spine Journal · doi:10.1016/j.spinee.2014.11.017 · Cited by 44
Thomsen, J. S., Niklassen, A. S., Ebbesen, E. N., & Brüel, A. (2013) · Bone · doi:10.1016/j.bone.2013.07.025 · Cited by 44
Hayashi, T., Chen, H., Miyamoto, K., Zhou, X., Hara, T., Yokoyama, R., Kanematsu, M., Hoshi, H., & Fujita, H. (2010) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-010-0204-1 · Cited by 43
“For similar research about the inhomogeneity of vertebrae, Banse et al. [ 20 ], Cody et al. [21], and Briggs et al. [29] have also investigated correlations between BMD and vertebral regions using pQCT, QCT, and DXA, respectively.”
MethodPathogenesis of Vertebral Anterior Wedge Deformity
Landham, P. R., Gilbert, S. J., Baker-Rand, H. L. A., Pollintine, P., Brown, K. A. R., Adams, M. A., & Dolan, P. (2015) · Spine · doi:10.1097/brs.0000000000000905 · Cited by 41
Hussein, A. I., Jackman, T. M., Morgan, S. R., Barest, G. D., & Morgan, E. F. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2417-3 · Cited by 39
Determination of vertebral endplate deformation under load using micro-computed tomography
Hulme, P. A., Ferguson, S. J., & Boyd, S. K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.07.018 · Cited by 38
Trabecular Architecture and Vertebral Fragility in Osteoporosis
Fields, A. J., & Keaveny, T. M. (2012) · Current Osteoporosis Reports · doi:10.1007/s11914-012-0097-0 · Cited by 37
“[56] found that trabecular architecture in the posterior regions was consistently denser, more connected, less separated, and more plate-like than in corresponding anterior regions; also, inferior regions were consistently denser and had a lower DA than superior regions, corroborating results from early histomorphomet…”
ResultBanse, X., Devogelaer, J. P., & Grynpas, M. D. (2002) · Bone · doi:10.1016/s8756-3282(02)00729-9 · Cited by 35
Self-citationUnnikrishnan, G. U., Barest, G. D., Berry, D. B., Hussein, A. I., & Morgan, E. F. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025179 · Cited by 32
Ma, C., Zou, D., Qi, H., Li, C., Zhang, C., Yang, K., Zhu, F., Li, W., & Lu, W. W. (2022) · Neurosurgical FOCUS · doi:10.3171/2022.1.focus21721 · Cited by 32
Hazrati, J., Ito, K., Taddei, F., & van Rietbergen, B. (2013) · Bone · doi:10.1016/j.bone.2013.12.019 · Cited by 31
Harrison, N. M., & McHugh, P. E. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-009-0188-8 · Cited by 30
Fletcher, S.-M. P., & O’Reilly, M. A. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2872171 · Cited by 30
“sity and complex trabecular structures [44].”
Aiyangar, A. K., Vivanco, J. F., Au, A. G., Anderson, P. A., Smith, E. L., & Ploeg, H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027663 · Cited by 29
Poullain, F., Champsaur, P., Pauly, V., Knoepflin, P., Corroller, T. L., Crézé, M., Pithioux, M., Bendahan, D., & Guenoun, D. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110642 · Cited by 29
Jang, I. G., & Kim, I. Y. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.042 · Cited by 29
Footprint mismatch in lumbar total disc arthroplasty
Michaela, G., Denise, H., Liebensteiner, M., & Michael, B. C. (2008) · European Spine Journal · doi:10.1007/s00586-008-0780-0 · Cited by 29
Wu, S., Todo, M., Umebayashi, D., & Yamamoto, Y. (2021) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2021.105365 · Cited by 28
Schröder, G., Reichel, M., Spiegel, S., Schulze, M., Götz, A., Bugaichuk, S., Andresen, J. R., Kullen, C. M., Andresen, R., & Schober, H. (2022) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-022-03105-5 · Cited by 27
Minimizing specimen length in elastic testing of end-constrained cancellous bone
Lievers, W. B., Waldman, S. D., & Pilkey, A. K. (2009) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2009.02.001 · Cited by 27
Schröder, G., Jabke, B., Schulze, M., Wree, A., Martin, H., Sahmel, O., Doerell, A., Kullen, C. M., Andresen, R., & Schober, H. (2021) · Anatomy & Cell Biology · doi:10.5115/acb.20.269 · Cited by 26
Glüer, C.-C., Scholz-Ahrens, K. E., Helfenstein, A., Delling, G., Timm, W., Açil, Y., Barkmann, R., Hassenpflug, J., Stampa, B., Bauss, F., et al. (2006) · Bone · doi:10.1016/j.bone.2006.10.019 · Cited by 25
Trabecular Architecture and Mechanical Heterogeneity Effects on Vertebral Body Strength
Auger, J., Frings, N. R., Wu, Y., Marty, A. G., & Morgan, E. F. (2020) · Current Osteoporosis Reports · doi:10.1007/s11914-020-00640-0 · Cited by 25
Deckelmann, S., Schwyn, R., van der Pol, B., Windolf, M., Heini, P. F., & Benneker, L. M. (2010) · Spine · doi:10.1097/brs.0b013e3181bc9470 · Cited by 25
“posterior and inferior regions compared to anterior and superior regions.(18) They reported the least dense area of”
BackgroundSeo, D. K., Kim, M. J., Roh, S. W., & Jeon, S. R. (2017) · Medicine · doi:10.1097/md.0000000000007816 · Cited by 25
Briggs, A. M., Wark, J. D., Kantor, S., Fazzalari, N. L., Greig, A. M., & Bennell, K. L. (2005) · Bone · doi:10.1016/j.bone.2005.07.018 · Cited by 23
Yerramshetty, J., Kim, D., & Yeni, Y. N. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3148473 · Cited by 20
Marangalou, J. H., Eckstein, F., Kühn, V., Ito, K., Cataldi, M., Taddei, F., & van Rietbergen, B. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2591-3 · Cited by 20
“It has been proposed that assessment of the weakest parts of the cancellous bone may lead to better prediction of fracture risk [18].”
Morphometric comparison of the lumbar cancellous bone of sheep, deer, and humans.
Wang, Y., Liu, G., Li, T., Xiao, Y., Han, Q., Xu, R., & Li, Y. (2010) · PubMed Central · Cited by 20
Wolfram, U., Wilke, H., & Zysset, P. K. (2010) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519410003241 · Cited by 19
Wolfram, U., Schmitz, B., Heuer, F., Reinehr, M. D., & Wilke, H. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.006 · Cited by 18
Popp, A. W., Schwyn, R., Schiuma, D., Keel, M. J. B., Lippuner, K., & Benneker, L. M. (2013) · The Spine Journal · doi:10.1016/j.spinee.2013.06.067 · Cited by 18
Singha, K. (2012) · Journal of Tissue Science & Engineering · doi:10.4172/2157-7552.1000118 · Cited by 17
Kurutz, M., Donath, Galos, Fornet, & Varga, P. (2008) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s4103 · Cited by 17
McDonnell, P., Harrison, N. M., & McHugh, P. E. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.02.005 · Cited by 16
Li, G., Zheng, X., Chen, Y., Chang, S., Calimente, H., Hu, J., & Wu, D. (2016) · Menopause The Journal of The North American Menopause Society · doi:10.1097/gme.0000000000000721 · Cited by 16
Briggs, A. M., Perilli, E., Parkinson, I. H., Kantor, S., Wrigley, T. V., Fazzalari, N. L., & Wark, J. D. (2011) · Journal of Bone and Mineral Metabolism · doi:10.1007/s00774-011-0307-3 · Cited by 14
“This approach precludes characterisation of any heterogeneity in the distribution of BMC within the vertebral body, despite a large volume of literature confirming that BMC is not homogenously distributed throughout the vertebral centrum [13–27] and that the distribution of bone mass relates to vertebral strength and…”
BackgroundDai, L., Wang, X., Wang, C., Jiang, L., & Xu, H. (2006) · European Spine Journal · doi:10.1007/s00586-006-0148-2 · Cited by 14
“cellous bone is not homogeneous inside the vertebral body [1, 3, 23], Bone mineral densitys (BMDs) with”
BackgroundHojjat, S., & Whyne, C. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.022 · Cited by 13
Augat, P. (2012) · Springer eBooks · doi:10.1007/978-3-642-02208-1_2 · Cited by 12
Briggs, A. M., Wark, J. D., Kantor, S., Teh, R., Greig, A. M., Fazzalari, N. L., & Bennell, K. L. (2005) · Journal of Clinical Densitometry · doi:10.1385/jcd:8:3:314 · Cited by 11
Dong, X. N., Pinninti, R., Tvinnereim, A., Lowe, T. W., DiPaolo, D. P., & Shirvaikar, M. V. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.041 · Cited by 10
“For example, the distribution of BMD within the human vertebrae is not homogeneous (Banse et al., 2001; Briggs et al., 2006).”
BackgroundShin, D. E., Lee, Y., An, H., Hwang, T.-S., Cho, J.-W., Oh, J., Ahn, W., Lee, J., Hong, C. G., Lee, Y., et al. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1238654 · Cited by 10
“reported transverse and vertical inhomogeneities in cancellous bone density inside the vertebral body using quantitative CT (pQCT) density analysis of the trabecular core (11).”
MethodExperimental quantification of bone mechanics
Bhattacharya, P., & van Lenthe, H. (2014) · Elsevier eBooks · doi:10.1533/9780857099037.1.30 · Cited by 9
Local and global microarchitecture is associated with different features of bone biomechanics
Roux, J.-P., Boutroy, S., Bouxsein, M., Chapurlat, R. D., & Wegrzyn, J. (2020) · Bone Reports · doi:10.1016/j.bonr.2020.100716 · Cited by 9
Regional apparent density correlations within the proximal humerus
Reeves, J. M., Vanasse, T., Roche, C. P., Athwal, G. S., Johnson, J. A., Faber, K. J., & Langohr, G. D. G. (2021) · JSES International · doi:10.1016/j.jseint.2020.12.001 · Cited by 9
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Warum sich in der Halswirbelsäule auch bei Osteoporose nur selten Insuffizienzfrakturen finden
Schröder, G., Hiepe, L., Moritz, M., Vivell, L.-M., Schulze, M., Martin, H., Götz, A., Andresen, J. R., Kullen, C. M., Andresen, R., et al. (2021) · Zeitschrift für Orthopädie und Unfallchirurgie · doi:10.1055/a-1647-3914 · Cited by 8
Agarwal, S. C. (2001) · TSpace (University of Toronto) · Cited by 8
Baleani, M., Fraterrigo, G., Erani, P., Rota, G., Berni, M., Taddei, F., & Schileo, E. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105706 · Cited by 8
Zarrinkalam, M. R., Schultz, C. G., Parkinson, I. H., & Moore, R. J. (2012) · Journal of Osteoporosis · doi:10.1155/2012/182509 · Cited by 8
“Micro-CT analysis shows that the central zone of sheep vertebrae has lower bone volume but thicker trabeculae that are spaced further apart, similar to humans [12, 22], although with no lateral variability [24].”
BackgroundMapping trabecular disconnection “hotspots” in aged human spine and hip
Aaron, J. E., Shore, P. A., Itoda, M., Morrison, R., Hartopp, A., Hensor, E. M. A., & Hordon, L. (2015) · Bone · doi:10.1016/j.bone.2015.04.009 · Cited by 7
Schröder, G., Baginski, A. M., Schulze, M., Hiepe, L., Bugaichuk, S., Martin, H., Andresen, J. R., Moritz, M., Andresen, R., & Schober, H. (2023) · Anatomical Science International · doi:10.1007/s12565-023-00726-6 · Cited by 7
Vibrational testing of trabecular bone architectures using rapid prototype models
Donnell, P. M., Liebschner, M. A. K., Tawackoli, W., & McHugh, P. E. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.04.012 · Cited by 6
Roessinger, O., Hügle, T., Walker, U. A., & Geurts, J. (2022) · Bone Reports · doi:10.1016/j.bonr.2022.101618 · Cited by 6
“Banse et al demonstrated that inhomogeneity exists in human vertebral trabecular bone, with posterior parts displaying up to 20 % higher values of Tb.BV/ TV (Banse et al., 2001), which appeared to be the opposite in mice, with higher Tb.BV/TV, Tb.”
Etude biomécanique des traumatismes vertébro-médullaires du rachis humain
Fradet, L. (2013) · theses.fr (ABES) · doi:10.70675/5fe84e68zca24z4d97za938z6ab135bcaf88 · Cited by 6
Schröder, G., Mittlmeier, T., Gahr, P., Ulusoy, S., Hiepe, L., Schulze, M., Götz, A., Andresen, R., & Schober, H. (2024) · Diagnostics · doi:10.3390/diagnostics14050498 · Cited by 6
Ni, L., Zhang, L., Xia, W., Chen, G., Cui, X.-D., Zhang, W., Luo, Z., & Yang, H. (2018) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2018.07.008 · Cited by 6
Unterweger, M.-T., Kandziora, F., & Schnake, K. J. (2015) · Case Reports in Orthopedics · doi:10.1155/2015/857607 · Cited by 6
“In osteoporotic spines, the posterior part with the lamina is stronger than the anterior parts [34].”
BackgroundIs Intervertebral Cement Leakage a Risk Factor for New Adjacent Vertebral Collapse?
Churojana, A., Songsaeng, D., Khumtong, R., Suwanbundit, A., & Saliou, G. (2014) · Interventional Neuroradiology · doi:10.15274/inr-2014-10079 · Cited by 6
Does Peripheral Quantitative Computed Tomography Ignore Tissue Density of Cancellous Bone?
Banse, X., & Devogelaer, J. P. (2002) · Journal of Clinical Densitometry · doi:10.1385/jcd:5:4:403 · Cited by 5
Self-citationKaspiris, A., Spyrou, I. G., Marougklianis, V., Afrati, S.-R., Sakellariou, E., Varsamos, I., Karampinas, P. K., Vasiliadis, E. S., & Pneumaticos, S. G. (2025) · Biomolecules · doi:10.3390/biom16010056 · Cited by 5
“These provide strong indications of a significant mechanical component in the pathogenesis of SK. Biomechanical data suggest reduced mineral density in the anterior portion of the thoracic vertebrae in adults [29].”
Kim, M., Oh, S. K., Choi, I. S., Seo, D. K., Roh, S. W., & Jeon, S. R. (2018) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2018.10.047 · Cited by 5
Integrated analysis of clinical indicators and mechanical properties in cancellous bone
He, J., Pan, Z., Zhou, G., Yu, J., & Li, D. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104245 · Cited by 4
Schröder, G., Akl, E., Hillebrand, J., Götz, A., Mittlmeier, T., Falk, S. S. I., Hiepe, L., Andresen, J. R., Andresen, R., Flachsmeyer, D., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14041059 · Cited by 4
“The spatial distribution of bone density within vertebrae exhibits significant variations, as demonstrated by Banse and colleagues [45] in their study.”
Metadata
- Authors
- Banse, X., Devogelaer, J. P., Munting, E., Delloye, C., Cornu, O., & Grynpas, M.
- Affiliations
- UCLouvain (BE)
- Mount Sinai Hospital (CA)
- Corresponding author
- Grynpas, M
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 28
- Issue
- 5
- Pages
- 563-571
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2100843879
- Cited by
- 130
- References
- 31
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 2 · 2023: 7 · 2022: 5 · 2021: 6 · 2020: 3 · 2019: 1 · 2018: 7 · 2017: 1 · 2016: 3 · 2015: 8 · 2014: 7 · 2013: 10 · 2012: 6
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Bone (publishedVersion)
- PubMed (publishedVersion)
- DIAL (Catholic University of Leuven) (submittedVersion)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Keywords
- vertebral cancellous bone, vertebral body, bone mineral density, trabecular structure, trabecular thickness, vertebral fracture risk, endplate, thoracic vertebrae, lumbar vertebrae, bone quality assessment, quantitative computed tomography, bone morphometry, trabecular bone score
- MeSH terms
- Adult, Aged, Aged, 80 and over, Female, Humans, Lumbar Vertebrae, Male, Middle Aged, Osteoporosis, Predictive Value of Tests, Spine, Thoracic Vertebrae, Tomography, X-Ray Computed, Bone Density, Causality, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.