Nanoindentation discriminates the elastic properties of individual human bone lamellae under dry and physiological conditions
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
Pharr, G. M., Oliver, W. C., & Brotzen, F. R. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.0613 · Cited by 1,562
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Zysset, P. K., Edward Guo, X., Edward Hoffler, C., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,006
Self-citationElastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Bone structure: from ångstroms to microns
Weiner, S., & Traub, W. (1992) · The FASEB Journal · doi:10.1096/fasebj.6.3.1740237 · Cited by 549
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Does microdamage accumulation affect the mechanical properties of bone?
Burr, D. B., Turner, C. H., Naick, P., Forwood, M. R., Ambrosius, W., Sayeed Hasan, M., & Pidaparti, R. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00016-5 · Cited by 417
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Nanoindentation of biological materials
Ebenstein, D. M., & Pruitt, L. A. (2006) · Nano Today · doi:10.1016/s1748-0132(06)70077-9 · Cited by 479
Substrate stiffness affects early differentiation events in embryonic stem cells
Dept Materials, R. S. O. M., Evans, N., Minelli, C., Gentleman, E., LaPointe, V, Patankar, S., Kallivretaki, M., Chen, X., Roberts, C., & Stevens, M. (2009) · European Cells and Materials · doi:10.22203/ecm.v018a01 · Cited by 466
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“The affected indentation volume features a semi-ellipsoid of approxi-701 mately nine times the indentation depth under the tip and a radius of about seven702 times the indentation depth (Hengsberger et al., 2002).”
BackgroundSelf-citationMethods for Assessing Bone Quality: A Review
Donnelly, E. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1702-0 · Cited by 300
Young’s modulus of trabecular bone at the tissue level: A review
Wu, D., Isaksson, P., Ferguson, S. J., & Persson, C. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.001 · Cited by 263
The Role of Water Compartments in the Material Properties of Cortical Bone
Granke, M., Does, M. D., & Nyman, J. S. (2015) · Calcified Tissue International · doi:10.1007/s00223-015-9977-5 · Cited by 252
Carrillo, F., Gupta, S., Balooch, M., Marshall, S. J., Marshall, G. W., Pruitt, L., & Puttlitz, C. M. (2005) · Journal of Materials Research · doi:10.1557/jmr.2005.0354 · Cited by 234
Donnelly, E., Baker, S. P., Boskey, A. L., & van der Meulen, M. C. H. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30633 · Cited by 208
Donnelly, E., Boskey, A. L., Baker, S. P., & van der Meulen, M. C. H. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32442 · Cited by 194
Boivin, G., Bala, Y., Doublier, A., Farlay, D., Ste-Marie, L. G., Meunier, P. J., & Delmas, P. D. (2008) · Bone · doi:10.1016/j.bone.2008.05.024 · Cited by 193
“Also, the indentations are typically very small, in bone tissue they are at the level of the lamellaewhich are not a level of investigation for bone remodeling [27,39,40].”
BackgroundSchwiedrzik, J., Raghavan, R., Bürki, A., LeNader, V., Wolfram, U., Michler, J., & Zysset, P. (2014) · Nature Materials · doi:10.1038/nmat3959 · Cited by 182
Self-citationEffect of microstructure on the mechanical properties of Haversian cortical bone
Hoc, T., Henry, L., Verdier, M., Aubry, D., Sedel, L., & Meunier, A. (2006) · Bone · doi:10.1016/j.bone.2005.09.017 · Cited by 173
Chevalier, Y., Pahr, D., Allmer, H., Charlebois, M., & Zysset, P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.004 · Cited by 168
Self-citationLewis, G., & Nyman, J. S. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31092 · Cited by 165
Bushby, A. J., Ferguson, V. L., & Boyde, A. (2004) · Journal of Materials Research · doi:10.1557/jmr.2004.0029 · Cited by 161
Takeuchi, K., Saruwatari, L., Nakamura, H. K., Yang, J., & Ogawa, T. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30227 · Cited by 159
Lloyd, A. A., Gludovatz, B., Riedel, C., Luengo, E. A., Saiyed, R., Marty, E., Lorich, D. G., Lane, J. M., Ritchie, R. O., Busse, B., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1704460114 · Cited by 158
“Although all nanoindentation tests used for nanoindentation analysis were performed on samples in a dehydrated state, previous literature suggests that sample drying and embedding would result in a linear increase in modulus of between 9 and 20% (43).”
MethodElastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89
Self-citationBucciarelli, A., Petretta, M., Grigolo, B., Gambari, L., Bossi, A. M., Grassi, F., & Maniglio, D. (2022) · Gels · doi:10.3390/gels8120833 · Cited by 31
Metadata
- Authors
- Hengsberger, S., Kulik, A., & Zysset, P.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2002-01
- Volume
- 30
- Issue
- 1
- Pages
- 178-184
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2053085627
- Cited by
- 363
- References
- 34
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.