The structure of cornea
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The anatomy and physiology of cornea has been described in reviews (Maurice, 1969; Davson, 1980). We are primarily concerned with the structure of the stroma of cornea. There are two levels of organization in the stroma: the collagen fibrils and the lamellae. Each lamella contains an array of collagen fibrils which appear as long thin cylinders in electron micrographs. The lamellae are parallel to the cornea surface and are at right angles to the light direction. Adjacent lamellae are approximately at right angles to each other. There are many lamellae (about 200) in the thickness of the stroma so that the different lamellae have on the average all possible orientations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129 · cited 10×
“Wiener's equation (Maurice, 1957) can be written in an approximate form”
BackgroundMethodInfluentialLight scattering in the cornea
Hart, R. W., & Farrell, R. A. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000766 · Cited by 237
Farrell, R. A., McCally, R. L., & Tatham, P. E. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010325 · Cited by 126
Cited by
Responses of human keratocytes to micro‐ and nanostructured substrates
Teixeira, A. I., Nealey, P. F., & Murphy, C. J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30089 · Cited by 243
Zhang, Y., Conrad, A. H., & Conrad, G. W. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.169813 · Cited by 193
Corneal collagen—its role in maintaining corneal shape and transparency
Meek, K. M. (2009) · Biophysical Reviews · doi:10.1007/s12551-009-0011-x · Cited by 183
“Fibril packing models described as “liquid-like” or “short-range ordered” have been shown theoretically to produce a transparent cornea (Farrell and Hart 1969; Worthington 1984), but the processes responsible for the development and maintenance of such systems are difficult to define because they are intrinsically non…”
Refractive indices of the collagen fibrils and extrafibrillar material of the corneal stroma
Leonard, D. W., & Meek, K. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78784-8 · Cited by 158
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139
Metadata
- Authors
- Worthington, C. R.
- Venue
- Quarterly Reviews of Biophysics
- Publisher
- Cambridge University Press (CUP)
- Published
- 1984-11
- Volume
- 17
- Issue
- 4
- Pages
- 423-451
- ISSN
- 0033-5835 (ISSN-L)
- 1469-8994
- OpenAlex
- W1974456075
- Cited by
- 28
- References
- 3
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.