CoChat

High-Accuracy 14C Measurements for Atmospheric CO2 Samples by AMS

Open access
Meijer, H A J, Pertuisot, M H, van der Plicht, J · 2006 · Radiocarbon
Cited by 32

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In this paper, we investigate how to achieve high-accuracy radiocarbon measurements by accelerator mass spectrometry (AMS) and present measurement series (performed on archived CO 2) of 14 CO 2 between 1985 and 1991 for Point Barrow (Alaska) and the South Pole. We report in detail the measurement plan, the error sources, and the calibration scheme that enabled us to reach a combined uncertainty of better than ±3%. The δ 13 C correction and a suggestion for a span (or 2-point) calibration for the 14 C scale are discussed in detail. In addition, we report new, accurate values for the calibration and reference materials Ox2 and IAEA-C6 with respect to Oxl. The atmospheric 14 CO 2 records (1985–1991) are presented as well and are compared with other existing records for that period. The Point Barrow record agrees very well with the existing Fruholmen (northern Norway) record from the same latitude. The South Pole record shows a small seasonal cycle but with an extreme phase with a maximum on January 1st (±13 days). Together with its generally elevated 14 C level compared to the Neumayer record (coastal Antarctica), this makes our South Pole data set a valuable additional source of information for global carbon cycle modeling using 14 CO 2 as a constraint.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0033822200038807

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • New Guidelines for δ 13 C Measurements

    Coplen, T. B., Brand, W. A., Gehre, M., Gröning, M., Meijer, H. A. J., Toman, B., & Verkouteren, R. M. (2006) · Analytical Chemistry · doi:10.1021/ac052027c · Cited by 906 · cited 1×

    “Experience in the stable isotope field (Coplen et al. 2006; Gon-fiantini 1984), however, has taught that the interlaboratory consistency benefits very much from the definition of (at least) 1 other calibration material.”
    Self-citation
  • Reporting 14C Activities and Concentrations

    Mook, W. G., & van der Plicht, J. (1999) · Radiocarbon · doi:10.1017/s0033822200057106 · Cited by 456

  • Natural atmospheric 14C variation and the Suess effect

    TANS, P. P., DE JONG, A. F. M., & MOOK, W. G. (1979) · Nature · doi:10.1038/280826a0 · Cited by 182 · cited 2×

    “Provided a large quantity of material is available for both samples and standards (tens of liters of CO 2 ), and with an exceptional amount of time invested, combined uncertainties 2 below ±2‰ can be achieved for samples <1 half-life old (Tans et al. 1979; de Jong 1981).”

Show all 3 references

Cited by

See all 32

Metadata

Authors
Meijer, H. A. J., Pertuisot, M. H., & van der Plicht, J.
Venue
Radiocarbon
Published
2006
Volume
48
Issue
3
Pages
355-372
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W2143137848
Cited by
32
References
3
FWCI
2.77
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Accuracy 14C Measurements for Atmospheric CO2 Samples by AMS. https://app.cochat.ai/papers/10.1017/s0033822200038807
The paper
Meijer, H. A. J., Pertuisot, M. H., & van der Plicht, J. (2006). High-Accuracy 14C Measurements for Atmospheric CO2 Samples by AMS. Radiocarbon. https://doi.org/10.1017/s0033822200038807

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.