CoChat

Blank Assessment for Ultra-Small Radiocarbon Samples: Chemical Extraction and Separation Versus AMS

Open access

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; 10 of the 23 sources its claims cite were checked for support.

Abstract

The Keck Carbon Cycle AMS facility at the University of California, Irvine (KCCAMS/UCI) has developed protocols for analyzing radiocarbon in samples as small as ∼0.001 mg of carbon (C). Mass-balance background corrections for modern and 14C-dead carbon contamination (MC and DC, respectively) can be assessed by measuring 14C-free and modern standards, respectively, using the same sample processing techniques that are applied to unknown samples. This approach can be validated by measuring secondary standards of similar size and 14C composition to the unknown samples. Ordinary sample processing (such as ABA or leaching pretreatment, combustion/graphitization, and handling) introduces MC contamination of ∼0.6 ± 0.3 μg C, while DC is ∼0.3 ± 0.15 μg C. Today, the laboratory routinely analyzes graphite samples as small as 0.015 mg C for external submissions and ≅0.001 mg C for internal research activities with a precision of ∼1% for ∼0.010 mg C. However, when analyzing ultra-small samples isolated by a series of complex chemical and chromatographic methods (such as individual compounds), integrated procedural blanks may be far larger and more variable than those associated with combustion/graphitization alone. In some instances, the mass ratio of these blanks to the compounds of interest may be so high that the reported 14C results are meaningless. Thus, the abundance and variability of both MC and DC contamination encountered during ultra-small sample analysis must be carefully and thoroughly evaluated. Four case studies are presented to illustrate how extraction chemistry blanks are determined.

Overview

CoChat Summary

TL;DR

The paper evaluates modern and dead carbon blanks for ultra-small radiocarbon samples at KCCAMS/UCI, distinguishing routine combustion/graphitization blanks from larger, more variable chemical extraction and separation blanks in compound-specific radiocarbon analysis (CSRA). It reports routine MC and DC blank levels and four CSRA case studies showing that procedural blanks can dominate ultra-small samples and must be assessed directly and indirectly.

Key findings

  • Routine sample processing introduced modern carbon (MC) contamination of ~0.6 ± 0.3 µg C and dead carbon (DC) contamination of ~0.3 ± 0.15 µg C; the laboratory routinely analyzed graphite samples as small as 0.015 mg C for external submissions and 0.001 mg C for internal research, with ~1% precision for ~0.010 mg C.
  • For CSRA, integrated procedural blanks may be far larger and more variable than combustion/graphitization blanks; in some cases the blank-to-compound mass ratio may be so high that reported 14C results are meaningless.
  • Case-study blanks included: marine fatty acids with MC 0.8 ± 0.4 µg C and DC 1.0 ± 0.5 µg C (75% of DC from pre-combustion sample preparation); soil PLFA PCGC DC varying from 0 to 0.002 mg C, with an average DC blank of 0.51 µg C (n = 73) and later MC estimated at 0.090 µg C; ocean PLFA/alkane combined chemical extraction and PCGC blank of 0.09–0.17 µg C/min/50 injections with combined 14C value 635 ± 21‰.
  • BPCA black carbon method: direct PCGC blank was 0.1 µg C/min/50 injections with 14C = 875 ± 34‰; indirect PCGC blank was 0.5 ± 0.3 µg C/min/50 injections with 14C = 800 ± 100‰; full chemical/separation direct blank was 1.1 ± 0.2 µg C/min/50 injections with 14C = 800 ± 54‰, and indirect full CSRA blank was 1.0 ± 0.5 µg C/min/50 injections with 14C = 850 ± 50‰.

Methods

  • Measured regular (1 mg C) to ultra-small (0.002 mg C) aliquots of 14C-free samples and secondary standards (NIST OX-I; FIRI-C and FIRI-D; IAEA-C6, -C7, and -C8) since 2005, applying mass-balance MC/DC corrections and on-line 13C AMS fractionation correction.
  • Conducted four CSRA case studies: fatty acids in marine sediments; phospholipid fatty acids (PLFAs) in 14C-elevated soils; PLFAs and alkanes in ocean sediments; and black carbon in marine dissolved organic carbon using the benzene polycarboxylic acid (BPCA) method.
  • Used direct blank assessments (carrier-only or no-sample through processing) and indirect assessments (known modern and dead standards treated as unknowns), with preparative capillary gas chromatography, combustion/graphitization, AMS measurement, and background subtraction formulas from Santos et al. (2007a); standards were forced to lie within ±2σ of consensus values.

Limitations

  • The paper states that no single ideal recipe is available to evaluate MC and DC blanks from CSRA procedures, and that blanks vary batch-to-batch, wheel-to-wheel, and with reagents/time; in some cases blanks are high enough to make results meaningless.
  • For the PLFA soil study, MC was not evaluated because a dead-FAME standard was unavailable; samples <0.010 mg C were disregarded, and errors greater than 50% were imposed to force standards within ±2σ. Low CO2 yields after pretreatment may indicate in situ contamination, making the source of residual C suspect.
  • Text-evident limitations include reliance on small numbers of measurements in some assessments (e.g., n = 1 for trap transfer, n = 5 for column tests) and case-specific standards; although direct and indirect BPCA blanks agreed, later tests with different solvent batches showed significant variation in blank magnitude and 14C.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1017/s0033822200046415

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 (a) to quantify the modern carbon (MC) contamination, ratios to OX-I (modern C standard) are shown for 14 C-free blanks (from 0.002 to 1 mg C) subjected to conventional acid/base/acid washes (organics: coal and wood blank) or surface leaching (carbonates: calcite); (b) to quantify the dead carbon (DC) component: fractional deviations of the ratios of small and ultra-small OX-I samples ( n = 90) of ~0.0015 to 0.2 mg C from those of the 1-mg C normalizing OX-I standards. Note that uncorrected 14 C results from smaller OXI samples are always depleted (e.g. fraction modern C values are lower than consensus values-see Figure 7a in Santos et al. 2007c). Error bars represent propagated errors. All results shown have been corrected for machine fractionation  13 C AMS. Diagonal lines in both plots represent fixed amounts of carbon contamination from 0.1 to 3  g C.
Figure 1 (a) to quantify the modern carbon (MC) contamination, ratios to OX-I (modern C standard) are shown for 14 C-free blanks (from 0.002 to 1 mg C) subjected to conventional acid/base/acid washes (organics: coal and wood blank) or surface leaching (carbonates: calcite); (b) to quantify the dead carbon (DC) component: fractional deviations of the ratios of small and ultra-small OX-I samples ( n = 90) of ~0.0015 to 0.2 mg C from those of the 1-mg C normalizing OX-I standards. Note that uncorrected 14 C results from smaller OXI samples are always depleted (e.g. fraction modern C values are lower than consensus values-see Figure 7a in Santos et al. 2007c). Error bars represent propagated errors. All results shown have been corrected for machine fractionation  13 C AMS. Diagonal lines in both plots represent fixed amounts of carbon contamination from 0.1 to 3  g C.From the PDF
Figure 2 (a) Fraction modern carbon results for OX-I samples between 0.002 and ~1 mg C from multiple 14 C AMS measurements are shown. All results have been corrected for fractionation using  13 C AMS measurements, and for MC and DC, contamination (blank subtraction formulas presented in Santos et al. 2007a); (b) illustrates the importance of correcting results with on-line  13 C AMS (which includes a correction for machine-induced isotopic fractionation) to achieve reliable results.
Figure 2 (a) Fraction modern carbon results for OX-I samples between 0.002 and ~1 mg C from multiple 14 C AMS measurements are shown. All results have been corrected for fractionation using  13 C AMS measurements, and for MC and DC, contamination (blank subtraction formulas presented in Santos et al. 2007a); (b) illustrates the importance of correcting results with on-line  13 C AMS (which includes a correction for machine-induced isotopic fractionation) to achieve reliable results.From the PDF
Figure 3 Secondary standards: fraction modern carbon and  13 C results for all IAEA standards, FIRI-C, and D samples between ~0.002 and ~1 mg C from multiple 14 C AMS measurements. All results have been corrected for MC and DC contamination (blank subtraction formulas given in Santos et al. 2007a) as well as for isotopic fractionation with on-line  13 C AMS values.
Figure 3 Secondary standards: fraction modern carbon and  13 C results for all IAEA standards, FIRI-C, and D samples between ~0.002 and ~1 mg C from multiple 14 C AMS measurements. All results have been corrected for MC and DC contamination (blank subtraction formulas given in Santos et al. 2007a) as well as for isotopic fractionation with on-line  13 C AMS values.From the PDF
Figure 4 (a) Indirect MC contamination assessment for the full CSRA procedure (black symbols) and combustion  graphitization steps only (gray symbols) using n C19 alcohol standard (  14 C  999‰). Diagonal lines represent fixed amounts of MC contamination from 0.2 to 3  g C (left to right); (b) Indirect DC contamination assessment for the full CSRA procedure ( n C21 fatty acids, light gray circles) and combustion  graphitization steps only (OX-I, dark gray diamonds). Measured values for a standard of intermediate radiocarbon composition ( iso C21 fatty acids, black squares) are also shown. Horizontal dashed lines denote the corresponding consensus values based on bulk-level measurements. All data were corrected for machine-induced isotopic fractionation.
Figure 4 (a) Indirect MC contamination assessment for the full CSRA procedure (black symbols) and combustion  graphitization steps only (gray symbols) using n C19 alcohol standard (  14 C  999‰). Diagonal lines represent fixed amounts of MC contamination from 0.2 to 3  g C (left to right); (b) Indirect DC contamination assessment for the full CSRA procedure ( n C21 fatty acids, light gray circles) and combustion  graphitization steps only (OX-I, dark gray diamonds). Measured values for a standard of intermediate radiocarbon composition ( iso C21 fatty acids, black squares) are also shown. Horizontal dashed lines denote the corresponding consensus values based on bulk-level measurements. All data were corrected for machine-induced isotopic fractionation.From the PDF

Verification

Claims the paper makes

8 Valid · 3 Not valid · 7 Not checked · 70 Own results and interpretations

49 more claims · 2 with their cited sources checked

Create a free account to see all 88 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 22
  • It may state two separate claims as one. 19

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Pearson A , Ingalls AE , Shah SR , Hansman RL , Aluwihare LI , Santos GM , Griffin S , Druffel ERM . 2005. Exploring the minimum sample size limit for CSRA: lessons from the water column [abstract]. 10th International Conference on Accelerator Mass Spectrometry, Berkeley, California, USA, 5–10 September 2005.

Cited by

See all 103

Metadata

Authors
Santos, G. M., Southon, J. R., Drenzek, N. J., Ziolkowski, L. A., Druffel, E., Xu, X., Zhang, D., Trumbore, S., Eglinton, T. I., & Hughen, K. A.
Affiliations
  • University of California, Irvine (US)
  • Woods Hole Oceanographic Institution (US)
Corresponding author
Santos, Guaciara M
Venue
Radiocarbon
Published
2010
Volume
52
Issue
3
Pages
1322-1335
ISSN
  • 0033-8222 (ISSN-L)
  • 1945-5755
OpenAlex
W2136174425
Cited by
103
References
28
Citations by year
2026: 2 · 2025: 5 · 2024: 1 · 2023: 5 · 2022: 3 · 2021: 8 · 2020: 8 · 2019: 8 · 2018: 8 · 2017: 6 · 2016: 10 · 2015: 9 · 2014: 3 · 2013: 13 · 2012: 7
FWCI
6.13
Type
journal article
Language
en
Open access
Locations
  • Radiocarbon (publishedVersion)
  • UA Campus Repository (The University of Arizona) (acceptedVersion)
  • Open Access Server of the Woods Hole Scientific Community (Woods Hole Scientific Community) (submittedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • eScholarship (California Digital Library) (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
Topics
  • Social Sciences › Archeology › Archaeology and ancient environmental studies
  • Physical Sciences › Physics and Astronomy › Radiation › Radioactive Decay and Measurement Techniques
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Geology and Paleoclimatology Research
Keywords
procedural blanks, chemical extraction, sample preparation, secondary standards

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-27, under version 3 of the claim definition (prompt extract-v3).

A second model labelled each claim on 2026-09-27 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.