CoChat

Impedance pneumography: Noise as signal in impedance cardiography

Ernst, John M., Litvack, Daniel A., Lozano, David L., Cacioppo, John T., Berntson, Gary G. · 1999 · Psychophysiology
Cited by 168

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of “noise” in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band electrodes. We recorded the change in impedance (Δ Z), the first derivative of the change in impedance (dZ/dt), output from a strain‐gauge respirometer, and criterion spirometry from eight healthy adults during rest, paced breathing, abdominal breathing, thoracic breathing, and a mental arithmetic task. Transfer function analyses revealed that a Δ Zd signal (derived by integration of the dZ/dt signal) provided the best estimate of the criterion spirometric measure for all parameters (coherence, phase, and gain), accounting for almost 90% of the variance in respiratory waveform morphology. The results document the potential utility of impedance pneumography, as derived from standard impedance cardiography signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0048577299981003

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Ernst, J. M., Litvack, D. A., Lozano, D. L., Cacioppo, J. T., & Berntson, G. G.
Venue
Psychophysiology
Publisher
Wiley
Published
1999-05
Volume
36
Issue
3
Pages
333-338
ISSN
  • 0048-5772 (ISSN-L)
  • 1469-8986
OpenAlex
W2104177943
Cited by
168
References
16
FWCI
2.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.