CoChat

Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in cat visual cortex

WILMS, MARCUS, EGER, MARCUS, SCHANZE, THOMAS, ECKHORN[dagger], REINHARD · 2003 · Visual Neuroscience
Cited by 39

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Blinds with receptor degeneration can perceive localized phosphenes in response to focal electrical epi-retinal stimuli. To avoid extensive basic stimulation tests in human patients, we developed techniques for estimating visual spatial resolution in anesthetized cats. Electrical epi-retinal and visual stimulation was combined with multiple-site retinal and cortical microelectrode recordings of local field potentials (LFPs) from visual areas 17 and 18. Classical visual receptive fields were characterized for retinal and cortical recording sites using multifocal visual stimulation combined with stimulus–response cross-correlation. We estimated visual spatial resolution from the size of the cortical activation profiles in response to single focal stimuli. For comparison, we determined activation profiles in response to visual stimuli at the same retinal location. Activation profiles were single peaked or multipeaked. In multipeaked profiles, the peak locations coincided with discontinuities in cortical retinotopy. Location and width of cortical activation profiles were distinct for retinal stimulation sites. On average, the activation profiles had a size of 1.28 ± 0.03 mm cortex. Projected to visual space this corresponds to a spatial resolution of 1.49 deg ± 0.04 deg visual angle. Best resolutions were 0.5 deg at low and medium stimulation currents corresponding to a visus of 1/30. Higher stimulation currents caused lower spatial, but higher temporal resolution (up to 70 stimuli/s). In analogy to the receptive-field concept in visual space, we defined and characterized electrical receptive fields. As our estimates of visual resolutions are conservative, we assume that a visual prosthesis will induce phosphenes at least at this resolution. This would enable visuomotor coordinations and object recognition in many indoor and outdoor situations of daily life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1017/s0952523803205083

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 39

Metadata

Authors
WILMS, M., EGER, M., SCHANZE, T., & ECKHORN[dagger], R.
Venue
Visual Neuroscience
Published
2003-09
Volume
20
Issue
5
Pages
543-555
ISSN
  • 0952-5238 (ISSN-L)
  • 1469-8714
OpenAlex
W2162812674
Cited by
39
References
6
FWCI
1.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in cat visual cortex. https://app.cochat.ai/papers/10.1017/s0952523803205083
The paper
WILMS, M., EGER, M., SCHANZE, T., & ECKHORN[dagger], R. (2003). Visual resolution with epi-retinal electrical stimulation estimated from activation profiles in cat visual cortex. Visual Neuroscience. https://doi.org/10.1017/s0952523803205083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.