Colocalization Analysis in Fluorescence Micrographs: Verification of a More Accurate Calculation of Pearson's Correlation Coefficient
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
One of the most routine uses of fluorescence microscopy is colocalization, i.e., the demonstration of a relationship between pairs of biological molecules. Frequently this is presented simplistically by the use of overlays of red and green images, with areas of yellow indicating colocalization of the molecules. Colocalization data are rarely quantified and can be misleading. Our results from both synthetic and biological datasets demonstrate that the generation of Pearson's correlation coefficient between pairs of images can overestimate positive correlation and fail to demonstrate negative correlation. We have demonstrated that the calculation of a thresholded Pearson's correlation coefficient using only intensity values over a determined threshold in both channels produces numerical values that more accurately describe both synthetic datasets and biological examples. Its use will bring clarity and accuracy to colocalization studies using fluorescent microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guided tour into subcellular colocalization analysis in light microscopy
BOLTE, S., & CORDELIÈRES, F. P. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01706.x · Cited by 5,324 · cited 2×
“In such plots spatial information is lost in favor of a means of assessing the degree of covariance of the image pair, as well as clues to the degree of bleed-through and noise in the images ~ Bolte & Cordelières, 2006 !”
BackgroundMethodInfluentialMeasurement of co‐localization of objects in dual‐colour confocal images
MANDERS, E. M. M., VERBEEK, F. J., & ATEN, J. A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03313.x · Cited by 2,154 · cited 6×
“Gaussian spots with a radius of 6 pixels were added in the positions described by Manders et al. ~ 1993 !”
BackgroundMethodInfluentialAutomatic and Quantitative Measurement of Protein-Protein Colocalization in Live Cells
Costes, S. V., Daelemans, D., Cho, E. H., Dobbin, Z., Pavlakis, G., & Lockett, S. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.038422 · Cited by 1,424 · cited 8×
“Our method of calculating thresholded PCC is not the same as the PCC of pixels above the thresholds set by applications that implement the approach of Costes et al. ~ 2004 ! such as JACoP.”
BackgroundMethodInfluentialImageJ, U.S. National Institutes of Health, Bethesda, Maryland, USA
Rasband, W. S. (2011) · Medical Entomology and Zoology · Cited by 1,221
Manders, E. M. M., Stap, J., Brakenhoff, G. J., Driel, R. V., & Aten, J. A. (1992) · Journal of Cell Science · doi:10.1242/jcs.103.3.857 · Cited by 739
Li, Q., Lau, A., Morris, T. J., Guo, L., Fordyce, C. B., & Stanley, E. F. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.0346-04.2004 · Cited by 708 · cited 1×
“These include a lack of objectivity, failure to identify covariance of intensities in the paired datasets, and possible overemphasis of trivial relationships ~ Costes et al., 2004; Li et al., 2004; Adler et al., 2008 !”
BackgroundZinchuk, V., Zinchuk, O., & Okada, T. (2007) · ACTA HISTOCHEMICA ET CYTOCHEMICA · doi:10.1267/ahc.07002 · Cited by 426 · cited 2×
“Zinchuk et al. ~ 2007 ! stated that negative values for PCC should be interpreted with caution, and that when values less than zero are generated one should consider switching to Manders’ overlap coefficient.”
BackgroundColocalization of fluorescent markers in confocal microscope images of plant cells
French, A. P., Mills, S., Swarup, R., Bennett, M. J., & Pridmore, T. P. (2008) · Nature Protocols · doi:10.1038/nprot.2008.31 · Cited by 369 · cited 1×
“& Cordelières, 2006; North, 2006; Adler et al., 2008; French et al., 2008; Scriven et al., 2008 !”
van Steensel, B., van Binnendijk, E. P., Hornsby, C. D., van der Voort, H. T. M., Krozowski, Z. S., de Kloet, E. R., & van Driel, R. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.787 · Cited by 357
Seeing is believing? A beginners' guide to practical pitfalls in image acquisition
North, A. J. (2006) · Journal of Cell Biology · doi:10.1083/jcb.200507103 · Cited by 257 · cited 1×
“& Cordelières, 2006; North, 2006; Adler et al., 2008; French et al., 2008; Scriven et al., 2008 !”
Replicate‐based noise corrected correlation for accurate measurements of colocalization
Adler, J., Pagakis, S. N., & Parmryd, I. (2008) · Journal of Microscopy · doi:10.1111/j.1365-2818.2008.01967.x · Cited by 79 · cited 5×
“A feature of PCC is that intensities distant from the mean carry more weight than those close to the mean ~ van Steensel et al., 1996; Adler et al., 2008 !”
BackgroundInfluentialAgnati, L. F., Fuxé, K., Torvinen, M., Genedani, S., Franco, R., Watson, S. J., Nussdorfer, G. G., Leo, G., & Guidolin, D. (2005) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.4a6355.2005 · Cited by 50
Image acquisition for colocalization using optical microscopy
Scriven, D. R. L., Lynch, R. M., & Moore, E. D. W. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00133.2008 · Cited by 46 · cited 1×
“& Cordelières, 2006; North, 2006; Adler et al., 2008; French et al., 2008; Scriven et al., 2008 !”
Cited by
Cytoskeletal Tension Inhibits Hippo Signaling through an Ajuba-Warts Complex
Rauskolb, C., Sun, S., Sun, G., Pan, Y., & Irvine, K. D. (2014) · Cell · doi:10.1016/j.cell.2014.05.035 · Cited by 353
Rodriguez-Diaz, R., Dando, R., Jacques-Silva, M. C., Fachado, A., Molina, J., Abdulreda, M. H., Ricordi, C., Roper, S. D., Berggren, P.-O., & Caicedo, A. (2011) · Nature Medicine · doi:10.1038/nm.2371 · Cited by 305
Wu, S., Lu, Q., Ding, Y., Wu, Y., Qiu, Y., Wang, P., Mao, X., Huang, K., Xie, Z., & Zou, M.-H. (2019) · Circulation · doi:10.1161/circulationaha.118.033552 · Cited by 298
SNX–BAR‐Mediated Endosome Tubulation is Co‐ordinated with Endosome Maturation
van Weering, J. R. T., Verkade, P., & Cullen, P. J. (2012) · Traffic · doi:10.1111/j.1600-0854.2011.01297.x · Cited by 169
“To gain more relevant colocalization information, we analyzed the relative signal intensities of the overlapping signal using Pearson’s correlation analysis, where 0 indicates no relationship (random colocalization), a value between 0 and 1 indicates a positive relation (where GFP signal is high, mCherry intensity is…”
MethodLiu, X., Su, Y., Tian, H., Yang, L., Zhang, H., Song, X., & Foley, J. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00754 · Cited by 167
Metadata
- Authors
- Barlow, A. L., MacLeod, A., Noppen, S., Sanderson, J., & Guérin, C. J.
- Venue
- Microscopy and Microanalysis
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-15
- Volume
- 16
- Issue
- 6
- Pages
- 710-724
- ISSN
- 1431-9276 (ISSN-L)
- 1435-8115
- OpenAlex
- W2122669551
- Cited by
- 166
- References
- 13
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.