Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in redox hydrogels
The DOI matches its Crossref record.
Abstract
Glucose microelectrodes have been formed with glucose oxidase immobilized in poly[(vinylpyridine)Os(bipyridine)2Cl] derivative-based redox hydrogels on beveled carbon-fiber microdisk (7 microns diameter) electrodes. In the resulting microelectrode, the steady-state glucose electrooxidation current density is 0.3 mA cm-2 and the sensitivity is 20 mA cm-2 M-1. The current density and sensitivity are 10 times higher than in macroelectrodes made with the same hydrogel. Furthermore, the current is less affected by a change in the partial pressure of oxygen. The higher current density and lower oxygen sensitivity point to the efficient collection of electrons through their diffusion in the redox hydrogel to the electrode surface. These results contrast with those observed for enzyme electrodes based on diffusing mediators, where loss of the enzyme-reduced mediator by radial diffusion to the solution decreases the current densities of microelectrodes relative to similar macroelectrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Ultrasound-Mediated Transdermal Protein Delivery
Mitragotri, S., Blankschtein, D., & Langer, R. (1995) · Science · doi:10.1126/science.7638603 · Cited by 791
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citationTechnology behind commercial devices for blood glucose monitoring in diabetes management: A review
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.07.024 · Cited by 209
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citationSchuhmann, W. (2002) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00058-7 · Cited by 166
Bartlett, P. N., & Pratt, K. F. E. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04236-7 · Cited by 164
Electroanalysis and Biosensors
Wang, J. (1999) · Analytical Chemistry · doi:10.1021/a1999905e · Cited by 159
Biocompatible, glucose-permeable hydrogel for in situ coating of implantable biosensors
Quinn, C. A. P., Connor, R. E., & Heller, A. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00125-7 · Cited by 126
Self-citation
Metadata
- Authors
- Pishko, M. V., Michael, A. C., & Heller, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1991-10-15
- Volume
- 63
- Issue
- 20
- Pages
- 2268-2272
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2094405050
- Cited by
- 148
- References
- 0
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.