Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Tandem mass spectrometry of very large molecules: serum albumin sequence information from multiply charged ions formed by electrospray ionization

Loo, Joseph A., Edmonds, Charles G., Smith, Richard D.·1991·Analytical Chemistry

Abstract

Serum albumin proteins, Mr approximately 66 kDa, from 10 different species (bovine, human, rat, horse, sheep, goat, rabbit, dog, porcine, and guinea pig) have been studied by electrospray ionization mass spectrometry (ESI-MS) and tandem MS using a triple-quadrupole instrument. The effectiveness of collisional activation for the multiply charged albumin ions greatly exceeds that for singly charged ions, allowing an extension by a factor of at least 20 to the molecular mass range for obtaining sequence-specific product ions by tandem MS. Efficient dissociation is largely attributed to "preheating" in the interface Coulombic instability and the large number of collisions. Increasing the electric field in the intermediate pressure region, between the nozzle-skimmer elements of the atmospheric pressure/vacuum interface, allows fragmentation of the multiply protonated (to 96+) molecules produced by ESI. The most abundant dissociation product ions assigned have a low charge state (2+ to 5+) and are attributed to "bn" mode species from cleavage of the -CO-N- peptide backbone bonds. Particularly abundant dissociation products originate from regions near residues n = 20-25 from the NH2 terminus for parent ions of moderate charge (approximately 50+). Collisionally activated dissociation (CAD) mass spectra from porcine serum albumin, in contrast to the other albumins, also gave prominent singly charged "yn" fragments formed from cleavages near the COOH terminus. Tandem mass spectrometry (MS/MS) of the multiply charged molecular ions, and of fragment species produced by dissociation in the interface (i.e., effective MS/MS/MS), produced similar "bn" species and served to confirm spectral assignments. We also show that ESI mass spectra allow a qualitative assessment of protein microheterogeneity and, in some cases, resolution of major contributions. The physical and analytical implications of the results are discussed, including the identification of possible errors in previously published sequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00021a018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Loo, J. A., Edmonds, C. G., & Smith, R. D.
Venue
Analytical Chemistry
Published
1991-11-01
Volume
63
Issue
21
Pages
2488-2499
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2021710187
Cited by
189
References
2
FWCI
12.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tandem mass spectrometry of very large molecules: serum albumin sequence information from multiply charged ions formed by electrospray ionization. https://app.cochat.ai/papers/10.1021/ac00021a018
The paper
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1991). Tandem mass spectrometry of very large molecules: serum albumin sequence information from multiply charged ions formed by electrospray ionization. Analytical Chemistry. https://doi.org/10.1021/ac00021a018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.