Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record.

A Microscale Electrospray Interface for Online, Capillary Liquid Chromatography/Tandem Mass Spectrometry of Complex Peptide Mixtures

Davis, Michael T., Stahl, Douglas C., Hefta, Stanley A., Lee, Terry D.·1995·Analytical Chemistry

Abstract

A microcapillary liquid chromatography (HPLC) system designed for the gradient elution of peptide and protein samples at flow rates < 1 microL/min has been coupled to a triple-sector quadrupole mass spectrometer via a simple sheathless electrospray interface (microspray). The microspray interface used a flame-drawn, uncoated, fused silica needle with tip outer diameters in the range of 15-20 microm and an opening less than 5 microm in diameter. Online sample filtration to prevent clogging of the drawn needle was accomplished by using a hydrophilic PVDF membrane filter integrated into the needle assembly. The spray potential (0.5-1 kV) was applied directly to the sample stream through the capillary union. Stable electrospray conditions were obtained over the full range of the gradient (0-90% acetonitrile in water) and was generally independent of flow rate. Both off-line and online analyses of proteins and peptide digest mixtures were performed at sample levels less than 10 fmol. HPLC parameters could be optimized for either rapid LC/MS analysis or enhanced performance in LC/MS/MS experiments by modulation of the eluting peak widths. Additionally, flow could be greatly reduced as selected components pass through the interface to prolong the time available to collect mass spectral data. The reduced spectral background and peak width manipulation facilitated the acquisition of peptide production spectra (MS/MS) using real-time, automated instrument control procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac00120a019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 201

Metadata

Authors
Davis, M. T., Stahl, D. C., Hefta, S. A., & Lee, T. D.
Venue
Analytical Chemistry
Published
1995-12-15
Volume
67
Issue
24
Pages
4549-4556
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1984302889
Cited by
201
References
0
FWCI
10.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microscale Electrospray Interface for Online, Capillary Liquid Chromatography/Tandem Mass Spectrometry of Complex Peptide Mixtures. https://app.cochat.ai/papers/10.1021/ac00120a019
The paper
Davis, M. T., Stahl, D. C., Hefta, S. A., & Lee, T. D. (1995). A Microscale Electrospray Interface for Online, Capillary Liquid Chromatography/Tandem Mass Spectrometry of Complex Peptide Mixtures. Analytical Chemistry. https://doi.org/10.1021/ac00120a019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.