The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
High-speed separations of DNA sequencing reactions by capillary electrophoresis
Abstract
Fluorescently labeled DNA fragments generated in enzymatic sequencing reactions are rapidly separated by capillary gel electrophoresis and detected at attomole levels within the gel-filled capillary. The application of this technology to automated DNA sequence analysis may permit the development of a second generation automated sequencer capable of efficient and cost-effective sequence analysis on the genomic scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
Fluorescence detection in automated DNA sequence analysis
Smith, L. M., Sanders, J. Z., Kaiser, R. J., Hughes, P., Dodd, C., Connell, C. R., Heiner, C., Kent, S. B. H., & Hood, L. E. (1986) · Nature · doi:10.1038/321674a0 · Cited by 1,714
Self-citationA System for Rapid DNA Sequencing with Fluorescent Chain-Terminating Dideoxynucleotides
Prober, J. M., Trainor, G. L., Dam, R. J., Hobbs, F. W., Robertson, C. W., Zagursky, R. J., Cocuzza, A. J., Jensen, M. A., & Baumeister, K. (1987) · Science · doi:10.1126/science.2443975 · Cited by 855
Cohen, A. S., Najarian, D. R., Paulus, A., Guttman, A., Smith, J. A., & Karger, B. L. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.24.9660 · Cited by 318
Bias in quantitative capillary zone electrophoresis caused by electrokinetic sample injection
Huang, X., Gordon, M. J., & Zare, R. N. (1988) · Analytical Chemistry · doi:10.1021/ac00155a023 · Cited by 226
Hjertén, S. (1983) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)96347-2 · Cited by 216
Automated DNA sequencing and analysis of the human genome
Hood, L., Hunkapiller, M. W., & Smith, L. M. (1987) · Genomics · doi:10.1016/0888-7543(87)90046-2 · Cited by 81
Self-citation
Cited by
High-Speed DNA Genotyping Using Microfabricated Capillary Array Electrophoresis Chips
Woolley, A. T., Sensabaugh, G. F., & Mathies, R. A. (1997) · Analytical Chemistry · doi:10.1021/ac961237+ · Cited by 310
High speed DNA sequencing by capillary electrophoresis
Luckey, J. A., Drossman, H., Kostichka, A. J., Mead, D. A., D'Cunha, J., Norris, T. B., & Smith, L. M. (1990) · Nucleic Acids Research · doi:10.1093/nar/18.15.4417 · Cited by 262
Self-citationDurney, B. C., Crihfield, C. L., & Holland, L. A. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8703-5 · Cited by 92
Analysis of therapeutic nucleic acids by capillary electrophoresis
Wei, B., Goyon, A., & Zhang, K. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.114928 · Cited by 50
Metadata
- Authors
- Drossman, H., Luckey, J. A., Kostichka, A. J., D'Cunha, J., & Smith, L. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-05-01
- Volume
- 62
- Issue
- 9
- Pages
- 900-903
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993868845
- Cited by
- 265
- References
- 7
- FWCI
- 40.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.