Closed-Loop, Multiobjective Optimization of Analytical Instrumentation: Gas Chromatography/Time-of-Flight Mass Spectrometry of the Metabolomes of Human Serum and of Yeast Fermentations
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The number of instrumental parameters controlling modern analytical apparatus can be substantial, and varying them systematically to optimize a particular chromatographic separation, for example, is out of the question because of the astronomical number of combinations that are possible (i.e., the "search space" is very large). However, heuristic methods, such as those based on evolutionary computing, can be used to explore such search spaces efficiently. We here describe the implementation of an entirely automated (closed-loop) strategy for doing this and apply it to the optimization of gas chromatographic separations of the metabolomes of human serum and of yeast fermentation broths. Without human intervention, the Robot Chromatographer system (i) initializes the settings on the instrument, (ii) controls the analytical run, (iii) extracts the variables defining the analytical performance (specifically the number of peaks, signal/noise ratio, and run time), (iv) chooses (via the PESA-II multiobjective genetic algorithm), and (v) programs the next series of instrumental settings, the whole continuing in an iterative cycle until suitable sets of optimal conditions have been established. Genetic programming was used to remove noise peaks and to establish the basis for the improvements observed. The system showed that the number of peaks observable depended enormously on the conditions used and served to increase them by as much as 3-fold (e.g., to over 950 in human serum) while in many cases maintaining or reducing the run time and preserving excellent signal/noise ratios. The evolutionary closed-loop machine learning strategy we describe is generic to any type of analytical optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Modeling: The Two Cultures (with comments and a rejoinder by the author)
Breiman, L. (2001) · Statistical Science · doi:10.1214/ss/1009213726 · Cited by 4,340
Cited by
Knowles, J. (2006) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2005.851274 · Cited by 1,254
Self-citationMeasuring the metabolome: current analytical technologies
Dunn, W. B., Bailey, N. J. C., & Johnson, H. E. (2005) · The Analyst · doi:10.1039/b418288j · Cited by 924
Self-citationDunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
Self-citationStatistical strategies for avoiding false discoveries in metabolomics and related experiments
Broadhurst, D. I., & Kell, D. B. (2007) · Metabolomics · doi:10.1007/s11306-006-0037-z · Cited by 817
Self-citationZelena, E., Dunn, W. B., Broadhurst, D., Francis-McIntyre, S., Carroll, K. M., Begley, P., O’Hagan, S., Knowles, J. D., Halsall, A., HUSERMET Consortium, et al. (2009) · Analytical Chemistry · doi:10.1021/ac8019366 · Cited by 811
Self-citationSelf-Driving Laboratories for Chemistry and Materials Science
Tom, G., Schmid, S. P., Baird, S. G., Cao, Y., Darvish, K., Hao, H., Lo, S., Pablo-García, S., Rajaonson, E. M., Skreta, M., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00055 · Cited by 707
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Analytical Strategies in Metabonomics
Lenz, E. M., & Wilson, I. D. (2007) · Journal of Proteome Research · doi:10.1021/pr0605217 · Cited by 530
Extraction and GC/MS Analysis of the Human Blood Plasma Metabolome
A, J., Trygg, J., Gullberg, J., Johansson, A. I., Jonsson, P., Antti, H., Marklund, S. L., & Moritz, T. (2005) · Analytical Chemistry · doi:10.1021/ac051211v · Cited by 528
Gika, H. G., Theodoridis, G. A., Wingate, J. E., & Wilson, I. D. (2007) · Journal of Proteome Research · doi:10.1021/pr070183p · Cited by 502
Plumb, R. S., Johnson, K. A., Rainville, P., Smith, B. W., Wilson, I. D., Castro‐Perez, J. M., & Nicholson, J. K. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2550 · Cited by 485
Metabolic footprinting and systems biology: the medium is the message
Kell, D. B., Brown, M., Davey, H. M., Dunn, W. B., Spasic, I., & Oliver, S. G. (2005) · Nature Reviews Microbiology · doi:10.1038/nrmicro1177 · Cited by 424
Self-citationMetabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Self-citationKell, D. B. (2010) · Archives of Toxicology · doi:10.1007/s00204-010-0577-x · Cited by 361
Self-citationQuantitative metabolomics based on gas chromatography mass spectrometry: status and perspectives
Koek, M. M., Jellema, R. H., van der Greef, J., Tas, A. C., & Hankemeier, T. (2011) · Metabolomics · doi:10.1007/s11306-010-0254-3 · Cited by 353
Metabolomic technologies and their application to the study of plants and plant–host interactions
Allwood, J. W., Ellis, D. I., & Goodacre, R. (2008) · Physiologia Plantarum · doi:10.1111/j.1399-3054.2007.01001.x · Cited by 301
Systems biology, metabolic modelling and metabolomics in drug discovery and development
Kell, D. B. (2006) · Drug Discovery Today · doi:10.1016/j.drudis.2006.10.004 · Cited by 297
Self-citationWinder, C. L., Dunn, W. B., Schuler, S., Broadhurst, D., Jarvis, R., Stephens, G. M., & Goodacre, R. (2008) · Analytical Chemistry · doi:10.1021/ac7023409 · Cited by 297
Self-citationDunn, W. B. (2008) · Physical Biology · doi:10.1088/1478-3975/5/1/011001 · Cited by 278
Self-citationBrown, M., Dunn, W. B., Dobson, P., Patel, Y., Winder, C. L., Francis-McIntyre, S., Begley, P., Carroll, K., Broadhurst, D., Tseng, A., et al. (2009) · The Analyst · doi:10.1039/b901179j · Cited by 269
Self-citationMark, H., & Harding, C. R. (2013) · International Journal of Cosmetic Science · doi:10.1111/ics.12019 · Cited by 75
“GC/MS analysis was performed as previously described [18] applying a LECO Pegasus III electron impact mass spectrometer (LECO, Stockport, U.”
Method
Metadata
- Authors
- O'Hagan, S., Dunn, W. B., Brown, M., Knowles, J. D., & Kell, D. B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-12-03
- Volume
- 77
- Issue
- 1
- Pages
- 290-303
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2109007223
- Cited by
- 153
- References
- 1
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.