Microfluidic Gradient-Generating Device for Pharmacological Profiling
The DOI matches its Crossref record.
Abstract
We describe an on-chip microfluidic gradient-generating device that generates concentration gradients spanning nearly 5 orders of magnitude starting from a single concentration. The exiting stream of drugs held at different concentrations remains laminar in a recording chamber and can be presented as 24 discrete solutions to a cell-based sensor. The high-performance characteristics of the device are demonstrated by pharmacological screening of voltage-gated K+ channels (hERG) and ligand-gated GABA(A) receptors using scanning-probe patch-clamp measurements. Multiple data point dose-response curves and IC50 and EC50 values were rapidly obtained, typically in less than 30 min, through its combined functionality of gradient generation and open-volume laminar flow. The device facilitates rapid pharmacological profiling of ion channel and GPCR effectors and enables the acquisition of large numbers of data points with minute sample consumption and handling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Applications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Analysis of single mammalian cells on-chip
Sims, C. E., & Allbritton, N. L. (2007) · Lab on a Chip · doi:10.1039/b615235j · Cited by 400
Microfluidics for single cell analysis
Yin, H., & Marshall, D. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.002 · Cited by 394
Kang, L., Chung, B. G., Langer, R., & Khademhosseini, A. (2008) · Drug Discovery Today · doi:10.1016/j.drudis.2007.10.003 · Cited by 325
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Microfluidic arrays for logarithmically perfused embryonic stem cell culture
Kim, L., Vahey, M. D., Lee, H.-Y., & Voldman, J. (2006) · Lab on a Chip · doi:10.1039/b511718f · Cited by 262
Biomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
A microfluidic platform for 3-dimensional cell culture and cell-based assays
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9016-4 · Cited by 166
Chang, C.-W., Cheng, Y.-J., Tu, M., Chen, Y.-H., Peng, C.-C., Liao, W.-H., & Tung, Y.-C. (2014) · Lab Chip · doi:10.1039/c4lc00732h · Cited by 154
Hydrogel-coated microfluidic channels for cardiomyocyte culture
Annabi, N., Selimović, Š., Acevedo Cox, J. P., Ribas, J., Afshar Bakooshli, M., Heintze, D., Weiss, A. S., Cropek, D., & Khademhosseini, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50252j · Cited by 129
Li, F., Macdonald, N. P., Guijt, R. M., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03228 · Cited by 74
Wu, M.-H., Chang, Y.-H., Liu, Y.-T., Chen, Y.-M., Wang, S.-S., Wang, H.-Y., Lai, C.-S., & Pan, T.-M. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.11.027 · Cited by 42
Metadata
- Authors
- Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-05-26
- Volume
- 77
- Issue
- 13
- Pages
- 3897-3903
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1996323464
- Cited by
- 135
- References
- 0
- FWCI
- 11.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.