CoChat

A microfluidic platform for 3-dimensional cell culture and cell-based assays

Kim, Minseok S., Yeon, Ju Hun, Park, Je-Kyun · 2007 · Biomedical Microdevices

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Abstract

This paper reports a novel microfluidic platform introducing peptide hydrogel to make biocompatible microenvironment as well as realizing in situ cell-based assays. Collagen composite, OPLA and Puramatrix scaffolds are compared to select good environment for human hepatocellular carcinoma cells (HepG2) by albumin measurement. The selected biocompatible self-assembling peptide hydrogel, Puramatrix, is hydrodynamically focused in the middle of main channel of a microfluidic device, and at the same time the cells are 3-dimensionally immobilized and encapsulated without any additional surface treatment. HepG2 cells have been 3-dimensionally cultured in a poly(dimethylsiloxane) (PDMS) microfluidic device for 4 days. The cells cultured in micro peptide scaffold are compared with those cultured by conventional petri dish in morphology and the rate of albumin secretion. By injection of different reagents into either side of the peptide scaffold, the microfluidic device also forms a linear concentration gradient profile across the peptide scaffold due to molecular diffusion. Based on this characteristic, toxicity tests are performed by Triton X-100. As the higher toxicant concentration gradient forms, the wider dead zone of cells in the peptide scaffold represents. This microfluidic platform facilitates in vivo-like 3-dimensional microenvironment, and have a potential for the applications of reliable cell-based screening and assays including cytotoxicity test, real-time cell viability…

Overview

Integrity signals

Registry

Crossref · 10.1007/s10544-006-9016-4

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 44 references

Research works printed but not linked: 3

  1. G.G. Giordano, R.C. Thomson, S.L. Ishaug, A.G. Mikos, S. Cumber, C.A. Garcia, and D. Lahiri-Munir, J. Biomed. Mater. Res. 34, 87–93 (1997). · doi:10.1002/(sici)1097-4636(199701)34:1<87::aid-jbm12>3.0.co;2-m
  2. J.A. Hubbell, Biotechnology 13, 565–576 (1995).
  3. D.J. Mooney, P.M. Kaufmann, K. Sano, S.P. Schwendeman, K. Majahod, B. Schloo, J.P. Vacanti, and R. Langer, Biotechnol. Bioeng. 50, 422–429 (1996). · doi:10.1002/(sici)1097-0290(19960520)50:4<422::aid-bit9>3.0.co;2-n

Cited by

See all 166

Metadata

Authors
Kim, M. S., Yeon, J. H., & Park, J.-K.
Affiliations
Korea Advanced Institute of Science and Technology (KR)
Corresponding author
Park, Je-Kyun
Venue
Biomedical Microdevices
Published
2006-11-11
Volume
9
Issue
1
Pages
25-34
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2074854692
Cited by
166
References
41
Citations by year
2026: 1 · 2025: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 8 · 2013: 13 · 2012: 10
FWCI
9.20
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Biomedical Microdevices (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
Keywords
microfluidic platform, 3D cell culture, self-assembling peptide hydrogel, PuraMatrix, cell-based assays, hepatocellular carcinoma cells, HepG2 cells, albumin secretion, hydrodynamic focusing, concentration gradient, cytotoxicity assay, cell viability monitoring, dose-response assay, PDMS microfluidic device
MeSH terms
Animals, Biological Assay, Cell Separation, Equipment Design, Flow Cytometry, Micromanipulation, Stress, Mechanical, Flow Injection Analysis, Cell Culture Techniques, Equipment Failure Analysis, Microfluidic Analytical Techniques, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microfluidic platform for 3-dimensional cell culture and cell-based assays. https://app.cochat.ai/papers/10.1007/s10544-006-9016-4
The paper
Kim, M. S., Yeon, J. H., & Park, J.-K. (2007). A microfluidic platform for 3-dimensional cell culture and cell-based assays. Biomedical Microdevices. https://doi.org/10.1007/s10544-006-9016-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.