The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Label-Free Protein Biosensor Based on Aptamer-Modified Carbon Nanotube Field-Effect Transistors
Abstract
We have fabricated label-free protein biosensors based on aptamer-modified carbon nanotube field-effect transistors (CNT-FETs) for the detection of immunoglobulin E (IgE). After the covalent immobilization of 5'-amino-modified 45-mer aptamers on the CNT channels, the electrical properties of the CNT-FETs were monitored in real time. The introduction of target IgE at various concentrations caused a sharp decrease in the source-drain current, and a gradual saturation was observed at lower concentrations. The amount of the net source-drain current before and after IgE introduction on the aptamer-modified CNT-FETs increased as a function of IgE concentration. The detection limit for IgE was determined as 250 pM. We have also prepared CNT-FET biosensors using a monoclonal antibody against IgE (IgE-mAb). The electrical properties of the aptamer- and antibody-modified CNT-FETs were compared. The performance of aptamer-modified CNT-FETs provided better results than the ones obtained using IgE-mAb-modified CNT-FETs under similar conditions. Thus, we suggest that the aptamer-modified CNT-FETs are promising candidates for the development of label-free protein biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
Selection in vitro of an RNA enzyme that specifically cleaves single-stranded DNA
Robertson, D. L., & Joyce, G. F. (1990) · Nature · doi:10.1038/344467a0 · Cited by 1,331
Ravetch, J. V., & Kinet, J. P. (1991) · Annual Review of Immunology · doi:10.1146/annurev.iy.09.040191.002325 · Cited by 1,229
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Sutton, B. J., & Gould, H. J. (1993) · Nature · doi:10.1038/366421a0 · Cited by 505
Aptasensors – the future of biosensing?
O'Sullivan, C. K. (2002) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-001-1189-3 · Cited by 410
High-affinity oligonucleotide ligands to human IgE inhibit binding to Fc ε receptor I
Wiegand, T. W., Williams, P. B., Dreskin, S. C., Jouvin, M. H., Kinet, J. P., & Tasset, D. (1996) · The Journal of Immunology · doi:10.4049/jimmunol.157.1.221 · Cited by 351
Cited by
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Electrolyte-Gated Graphene Field-Effect Transistors for Detecting pH and Protein Adsorption
Ohno, Y., Maehashi, K., Yamashiro, Y., & Matsumoto, K. (2009) · Nano Letters · doi:10.1021/nl901596m · Cited by 833
Self-citationElectrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Wepasnick, K. A., Smith, B. A., Schrote, K. E., Wilson, H. K., Diegelmann, S. R., & Fairbrother, D. H. (2011) · Carbon · doi:10.1016/j.carbon.2010.08.034 · Cited by 750
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
A Graphene Oxide Based Immuno‐biosensor for Pathogen Detection
Jung, J. H., Cheon, D. S., Liu, F., Lee, K. B., & Seo, T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201001428 · Cited by 563
Label-Free Biosensors Based on Aptamer-Modified Graphene Field-Effect Transistors
Ohno, Y., Maehashi, K., & Matsumoto, K. (2010) · Journal of the American Chemical Society · doi:10.1021/ja108127r · Cited by 554
Self-citationCarbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules
Kim, S. N., Rusling, J. F., & Papadimitrakopoulos, F. (2007) · Advanced Materials · doi:10.1002/adma.200700665 · Cited by 502
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Seok Kim, Y., Ahmad Raston, N. H., & Bock Gu, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.040 · Cited by 442
Nucleic Acid and Peptide Aptamers: Fundamentals and Bioanalytical Aspects
Mascini, M., Palchetti, I., & Tombelli, S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201006630 · Cited by 374
Advances in Bioapplications of Carbon Nanotubes
Lu, F., Gu, L., Meziani, M. J., Wang, X., Luo, P. G., Veca, L. M., Cao, L., & Sun, Y. (2009) · Advanced Materials · doi:10.1002/adma.200801491 · Cited by 362
Supersensitive, Fast‐Response Nanowire Sensors by Using Schottky Contacts
Hu, Y., Zhou, J., Yeh, P., Li, Z., Wei, T., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.201000278 · Cited by 346
Vashist, S. K., Lam, E., Hrapovic, S., Male, K. B., & Luong, J. H. T. (2014) · Chemical Reviews · doi:10.1021/cr5000943 · Cited by 345
Nucleic Acid Conjugated Nanomaterials for Enhanced Molecular Recognition
Wang, H., Yang, R., Yang, L., & Tan, W. (2009) · ACS Nano · doi:10.1021/nn9006303 · Cited by 329
Graphene/MoS2 Heterostructures for Ultrasensitive Detection of DNA Hybridisation
Loan, P. T. K., Zhang, W., Lin, C., Wei, K., Li, L., & Chen, C. (2014) · Advanced Materials · doi:10.1002/adma.201401084 · Cited by 322
Two-dimensional Layered MoS2 Biosensors Enable Highly Sensitive Detection of Biomolecules
Lee, J., Dak, P., Lee, Y., Park, H., Choi, W., Alam, M. A., & Kim, S. (2014) · Scientific Reports · doi:10.1038/srep07352 · Cited by 318
Surface immobilization methods for aptamer diagnostic applications
Balamurugan, S., Obubuafo, A., Soper, S. A., & Spivak, D. A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1587-2 · Cited by 312
Li, X., Shan, J., Zhang, W., Su, S., Yuwen, L., & Wang, L. (2017) · Small · doi:10.1002/smll.201602660 · Cited by 301
Molecular diagnostic and drug delivery agents based on aptamer-nanomaterial conjugates
Lee, J. H., Yigit, M. V., Mazumdar, D., & Lu, Y. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.03.003 · Cited by 293
Carbon Nanotube (CNT)-Based Biosensors
Ferrier, D. C., & Honeychurch, K. C. (2021) · Biosensors · doi:10.3390/bios11120486 · Cited by 287
Jolly, P., Tamboli, V., Harniman, R. L., Estrela, P., Allender, C. J., & Bowen, J. L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.043 · Cited by 286
Chemistry of carbon nanotubes in biomedical applications
Wu, H.-C., Chang, X., Liu, L., Zhao, F., & Zhao, Y. (2010) · J. Mater. Chem. · doi:10.1039/b911099m · Cited by 280
Aptamers as molecular recognition elements for electrical nanobiosensors
Lee, J.-O., So, H.-M., Jeon, E.-K., Chang, H., Won, K., & Kim, Y. H. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1643-y · Cited by 277
Nanotechnology and aptamers: applications in drug delivery
Levy-Nissenbaum, E., Radovic-Moreno, A. F., Wang, A. Z., Langer, R., & Farokhzad, O. C. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.04.006 · Cited by 270
Gao, N., Zhou, W., Jiang, X., Hong, G., Fu, T.-M., & Lieber, C. M. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b00133 · Cited by 268
Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Munje, R. D., Muthukumar, S., Panneer Selvam, A., & Prasad, S. (2015) · Scientific Reports · doi:10.1038/srep14586 · Cited by 138
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Detection of Orexin A Neuropeptide in Biological Fluids Using a Zinc Oxide Field Effect Transistor
Hagen, J., Lyon, W., Chushak, Y., Tomczak, M., Naik, R., Stone, M., & Kelley-Loughnane, N. (2013) · ACS Chemical Neuroscience · doi:10.1021/cn300159e · Cited by 22
Metadata
- Authors
- Maehashi, K., Katsura, T., Kerman, K., Takamura, Y., Matsumoto, K., & Tamiya, E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-09
- Volume
- 79
- Issue
- 2
- Pages
- 782-787
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2030205465
- Cited by
- 660
- References
- 18
- FWCI
- 14.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.