The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Noninvasive Acoustic Cell Trapping in a Microfluidic Perfusion System for Online Bioassays
Open accessAbstract
Techniques for manipulating, separating, and trapping particles and cells are highly desired in today's bioanalytical and biomedical field. The microfluidic chip-based acoustic noncontact trapping method earlier developed within the group now provides a flexible platform for performing cell- and particle-based assays in continuous flow microsystems. An acoustic standing wave is generated in etched glass channels (600x61 microm2) by miniature ultrasonic transducers (550x550x200 microm3). Particles or cells passing the transducer will be retained and levitated in the center of the channel without any contact with the channel walls. The maximum trapping force was calculated to be 430+/-135 pN by measuring the drag force exerted on a single particle levitated in the standing wave. The temperature increase in the channel was characterized by fluorescence measurements using rhodamine B, and levels of moderate temperature increase were noted. Neural stem cells were acoustically trapped and shown to be viable after 15 min. Further evidence of the mild cell handling conditions was demonstrated as yeast cells were successfully cultured for 6 h in the acoustic trap while being perfused by the cell medium at a flowrate of 1 microL/min. The acoustic microchip method facilitates trapping of single cells as well as larger cell clusters. The noncontact mode of cell handling is especially important when studies on nonadherent cells are performed, e.g., stem cells, yeast cells, or blood cells, as mechanical stress and surface interaction are minimized. The demonstrated acoustic trapping of cells and particles enables cell- or particle-based bioassays to be performed in a continuous flow format.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
History of optical trapping and manipulation of small-neutral particle, atoms, and molecules
Ashkin, A. (2000) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.902132 · Cited by 635
Renfranz, P. J., Cunningham, M. G., & McKay, R. D. G. (1991) · Cell · doi:10.1016/0092-8674(91)90116-g · Cited by 472
Lights, action: Optical tweezers
Molloy, J. E., & Padgett, M. J. (2002) · Contemporary Physics · doi:10.1080/00107510110116051 · Cited by 385
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2005) · Lab Chip · doi:10.1039/b405748c · Cited by 360
Self-citationSeparation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330
Self-citationZheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
Semler, E. J., Ranucci, C. S., & Moghe, P. V. (2000) · Biotechnology and Bioengineering · doi:10.1002/1097-0290(20000820)69:4<440::aid-bit10>3.0.co;2-0 · Cited by 132
Bazou, D., Kuznetsova, L. A., & Coakley, W. T. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.12.007 · Cited by 95
Harnessing dielectric forces for separations of cells, fine particles and macromolecules
Gonzalez, C. F., & Remcho, V. T. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.070 · Cited by 79
Cited by
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Review of cell and particle trapping in microfluidic systems
Nilsson, J., Evander, M., Hammarström, B., & Laurell, T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.07.017 · Cited by 534
Self-citationContinuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Self-citationMicro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Microfluidic, Label-Free Enrichment of Prostate Cancer Cells in Blood Based on Acoustophoresis
Augustsson, P., Magnusson, C., Nordin, M., Lilja, H., & Laurell, T. (2012) · Analytical Chemistry · doi:10.1021/ac301723s · Cited by 352
Self-citationAcoustofluidics 12: Biocompatibility and cell viability in microfluidic acoustic resonators
Wiklund, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40201g · Cited by 338
Acoustofluidics for biomedical applications
Rufo, J., Cai, F., Friend, J., Wiklund, M., & Huang, T. J. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00109-7 · Cited by 305
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Overview of single-cell analyses: microdevices and applications
Lindström, S., & Andersson-Svahn, H. (2010) · Lab on a Chip · doi:10.1039/c0lc00150c · Cited by 260
Metadata
- Authors
- Evander, M., Johansson, L., Lilliehorn, T., Piskur, J., Lindvall, M., Johansson, S., Almqvist, M., Laurell, T., & Nilsson, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-22
- Volume
- 79
- Issue
- 7
- Pages
- 2984-2991
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2081021011
- Cited by
- 281
- References
- 13
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.