Simplifying CE−MS Operation. 2. Interfacing Low-Flow Separation Techniques to Mass Spectrometry Using a Porous Tip
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A robust, reproducible, and single-step interface design between low flow rate separation techniques, such as sheathless capillary electrophoresis (CE) and nanoliquid chromatography (nLC), and mass spectrometry (MS) using electrospray ionization (ESI), is introduced. In this design, the electrical connection to the capillary outlet was achieved through a porous tip at the capillary outlet. The porous section was created by removing 1-1.5 in. of the polyimide coating of the capillary and etching this section by 49% solution of HF until it is porous. The electrical connection to the capillary outlet is achieved simply by inserting the capillary outlet containing the porous tip into the existing ESI needle (metal sheath) and filling the needle with the background electrolyte. Redox reactions of water at the ESI needle and transport of these small ions through the porous tip into the capillary provides the electrical connection for the ESI and for the CE outlet electrode. The etching process reduces the wall thickness of the etched section, including the tip of the capillary, to 5-10 microm, which for a 20-30 microm i.d. capillary results in stable electrospray at approximately 1.5 kV. The design is suitable for interfacing a wide range of capillary sizes with a wide range of flow rates to MS via ESI, but it is especially useful for interfacing narrow (<30 microm i.d.) capillaries and low flow rates (<100 nL/min). The advantages of the porous tip design include the following: (1) its fabrication is reproducible, can be automated, and does not require any mechanical tools. (2) The etching process reduces the tip outer diameter and makes the capillary porous in one step. (3) The interface can be used for both nLC-MS and CE-MS. (4) If blocked or damaged, a small section of the tip can be etched off without any loss of performance. (5) The interface design leaves the capillary inner wall intact and, therefore, does not add any dead volume to the CE-MS or nLC-MS interface. (6) Bubble formation due to redox reactions of water at the high-voltage electrode is outside of the separation capillary and does not affect separation or MS performances. The performance of this interface is demonstrated by the analyses of amino acids, peptide, and protein mixtures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Peer Reviewed: Advances in CE/MS.
Ding, J., & Vouros, P. (1999) · Analytical Chemistry · doi:10.1021/ac9904415 · Cited by 116
Guzman, N. A., & Stubbs, R. J. (2001) · Electrophoresis · doi:10.1002/1522-2683(200109)22:17<3602::aid-elps3602>3.0.co;2-x · Cited by 110
Moini, M., Jones, B. L., Rogers, R. M., & Jiang, L. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00079-8 · Cited by 106
Self-citationMoini, M. (2001) · Analytical Chemistry · doi:10.1021/ac010189c · Cited by 86
Self-citationMoini, M., Schultz, C. L., & Mahmood, H. (2003) · Analytical Chemistry · doi:10.1021/ac034708i · Cited by 81
Self-citationCapillary Electrophoresis to Mass Spectrometry Interface Using a Porous Junction
Whitt, J. T., & Moini, M. (2003) · Analytical Chemistry · doi:10.1021/ac026380j · Cited by 74
Self-citationSettlage, R. E., Russo, P. S., Shabanowitz, J., & Hunt, D. F. (1998) · Journal of Microcolumn Separations · doi:10.1002/(sici)1520-667x(1998)10:3<281::aid-mcs7>3.0.co;2-c · Cited by 61
Jiang, L., & Moini, M. (1999) · Analytical Chemistry · doi:10.1021/ac990777e · Cited by 52
Self-citationAnalysis of Complex Protein Mixtures with Improved Sequence Coverage Using (CE−MS/MS)n
Garza, S., & Moini, M. (2006) · Analytical Chemistry · doi:10.1021/ac0612269 · Cited by 52
Self-citationMoini, M., Demars, S. M., & Huang, H. (2002) · Analytical Chemistry · doi:10.1021/ac020022z · Cited by 52
Self-citationCapillary Electrophoresis of Proteins and Peptides
Strege, M. A., & Lagu, A. L. (2004) · Humana Press eBooks · doi:10.1385/159259798x · Cited by 43
Cited by
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216
“[4,5] Moini reported a sheathless interface in 2007,[6] which employed a porous capillary tip as the nanospray emitter.”
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Ultrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212
Identification and Quantification of Proteoforms by Mass Spectrometry
Schaffer, L. V., Millikin, R. J., Miller, R. M., Anderson, L. C., Fellers, R. T., Ge, Y., Kelleher, N. L., LeDuc, R. D., Liu, X., Payne, S. H., et al. (2019) · PROTEOMICS · doi:10.1002/pmic.201800361 · Cited by 209
Metadata
- Authors
- Moini, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-04-21
- Volume
- 79
- Issue
- 11
- Pages
- 4241-4246
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018236745
- Cited by
- 322
- References
- 12
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.