The DOI matches its Crossref record.
Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip
Abstract
We describe a disposable electrochemical immunosensor diagnosis device that integrates the immunochromatographic strip technique with an electrochemical immunoassay and exploits quantum dot (QD, CdS@ZnS) as labels for amplifying signal output. The device takes advantage of the speed and low cost of the conventional immunochromatographic strip test and the high sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1-10 ng mL(-1) IgG, and the limit of detection is estimated to be 30 pg mL(-1) in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL(-1) using a 20-min immunoreaction time. The device has been successfully applied for the detection of prostate-specific antigen (PSA) in human serum sample with a detection limit of 20 pg mL(-1). The results were validated by using the commercial PSA enzyme-linked immunosorbent assay kit and showed high consistency. The new disposable electrochemical diagnosis device thus provides a rapid, clinically accurate, and quantitative tool for protein biomarker detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Semiconductor Quantum Dots for Bioanalysis
Gill, R., Zayats, M., & Willner, I. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800169 · Cited by 902
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
Self-citationRecent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 373
Du, D., Wang, L., Shao, Y., Wang, J., Engelhard, M. H., & Lin, Y. (2011) · Analytical Chemistry · doi:10.1021/ac101715s · Cited by 306
Self-citationBiomarker detection technologies and future directions
Nimse, S. B., Sonawane, M. D., Song, K.-S., & Kim, T. (2016) · The Analyst · doi:10.1039/c5an01790d · Cited by 275
Biomolecule-nanoparticle hybrids for electrochemical biosensors
GUO, S., & DONG, S. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.10.014 · Cited by 274
Zhang, W., Asiri, A. M., Liu, D., Du, D., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.10.007 · Cited by 270
Self-citationLateral-flow technology: From visual to instrumental
Mak, W. C., Beni, V., & Turner, A. P. F. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.017 · Cited by 264
Multifunctional dendrimer-entrapped gold nanoparticles for dual mode CT/MR imaging applications
Wen, S., Li, K., Cai, H., Chen, Q., Shen, M., Huang, Y., Peng, C., Hou, W., Zhu, M., Zhang, G., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.010 · Cited by 257
Electrochemical sensors based on metal and semiconductor nanoparticles
Wang, F., & Hu, S. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0136-4 · Cited by 255
Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures
Barry, R. C., Lin, Y., Wang, J., Liu, G., & Timchalk, C. A. (2009) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2008.71 · Cited by 73
Self-citation
Metadata
- Authors
- Liu, G., Lin, Y.-Y., Wang, J., Wu, H., Wai, C. M., & Lin, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-19
- Volume
- 79
- Issue
- 20
- Pages
- 7644-7653
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2029761753
- Cited by
- 232
- References
- 0
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.