CoChat

Prospects of Deep Raman Spectroscopy for Noninvasive Detection of Conjugated Surface Enhanced Resonance Raman Scattering Nanoparticles Buried within 25 mm of Mammalian Tissue

Stone, Nicholas, Faulds, Karen, Graham, Duncan, Matousek, Pavel · 2010 · Analytical Chemistry

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

This letter discusses the potential of deep Raman spectroscopy, surface enhanced spatially offset Raman spectroscopy (SESORS and its variants), for noninvasively detecting small, deeply buried lesions using surface enhanced resonance Raman scattering (SERRS) active nanoparticles. An experimental demonstration of this concept is performed in transmission Raman geometry. This method opens prospects for in vivo, noninvasive, specific detection of molecular changes associated with disease up to depths of several centimeters representing significant improvement over traditionally detected Raman signals by 2 orders of magnitude. The disease specific signals can be achieved using uniquely tagged nanoparticles conjugated to target molecules, e.g., antibodies for production of the SERRS signal. This provides the molecular specific signal which is many orders of magnitude greater than normal biological Raman signals and can be easily multiplexed. To date, there have been no studies demonstrating the viability of deep Raman spectroscopy coupled to surface enhanced techniques for detecting low concentrations of molecules of interest at depths of greater than 5.5 mm in tissue. Such a breakthrough would open a host of new applications in medical diagnoses. Here we propose to facilitate such capability by combining SERRS (as a probe for disease specific changes) with deep Raman spectroscopy techniques. This permits noninvasive measurement of Raman signatures from conjugated SERRS nanopartic…

Overview

Integrity signals

Registry

Crossref · 10.1021/ac100039c

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 33 references

Research works printed but not linked: 2

  1. Liu Y. N., 2007, Spectrosc. Spectral Anal., 27, 2045
  2. Rao C. G., 2005, Int. J. Oncol., 27, 49

Cited by

See all 140

Metadata

Authors
Stone, N., Faulds, K., Graham, D., & Matousek, P.
Affiliations
Rutherford Appleton Laboratory (GB)
Corresponding author
Stone, Nicholas
Venue
Analytical Chemistry
Published
2010-04-16
Volume
82
Issue
10
Pages
3969-3973
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2042918382
Cited by
140
References
34
Citations by year
2026: 3 · 2025: 2 · 2024: 10 · 2023: 7 · 2022: 8 · 2021: 5 · 2020: 7 · 2019: 7 · 2018: 11 · 2017: 12 · 2016: 6 · 2015: 13 · 2014: 5 · 2013: 15 · 2012: 15
FWCI
8.52
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • Science and Technology Facilities Council (submittedVersion)
Funders
  • National Institute for Health and Care Research (CSA/03/07/017)
  • National Institutes of Health
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
Keywords
surface-enhanced resonance Raman scattering, non-invasive detection, antibody-conjugated nanoparticles, molecular imaging
MeSH terms
Animals, Spectrum Analysis, Raman, Surface Properties, Swine, Signal Transduction, Biomarkers, Antisense Elements (Genetics), Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.