CoChat

Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications

Open access
Gomez-Sjoberg, Rafael, Leyrat, Anne A., Houseman, Benjamin T., Shokat, Kevan, Quake, Stephen R. · 2010 · Analytical Chemistry

The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.

Abstract

Poly(dimethyl siloxane) (PDMS)-based microfluidic devices are now commonly used for a wide variety of biological experiments, including cell culture assays. However, the porous, hydrophobic polymer matrix of PDMS rapidly absorbs small hydrophobic molecules, including hormones and most small-molecule drugs. This makes it challenging to perform experiments that require such substances in PDMS microfluidic devices. This study presents evidence that a sol-gel treatment of PDMS that fills the polymer matrix with silica nanoparticles is effective at reducing the absorption of drugs into the material while preserving its biocompatibility, transparency, and oxygen permeability. We show that the absorption of two anticancer drugs, camptothecin and a kinase inhibitor, is reduced to such an extent that on-chip microfluidic cell culture experiments can recapitulate the results obtained off-chip.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac101870s

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R.
Affiliations
  • Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States, Department of Bioengineering and Howard Hughes Medical Institute, Stanford University, Stanford, California 94305, United States, Department of Anesthesia and Perioperative Care, San Francisco General Hospital, San Francisco, California 94143, United States, and Department of Cellular and Molecular Pharmacology and Howard Hughes Medical Institute, University of California San Francisco, San Francisco,...
  • San Francisco General Hospital (US)
Venue
Analytical Chemistry
Published
2010-10-11
Volume
82
Issue
21
Pages
8954-8960
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1964121777
Cited by
104
References
24
Citations by year
2026: 8 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 11 · 2021: 10 · 2020: 8 · 2019: 7 · 2018: 7 · 2017: 8 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 8 · 2012: 2
FWCI
2.46
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Howard Hughes Medical Institute
  • Mount Zion Health Fund
  • National Institutes of Health (DP1OD000251)
  • University of California, San Francisco
  • National Cancer Institute
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
polydimethylsiloxane, sol-gel treatment, silica nanoparticles, drug absorption, microfluidic cell culture, biocompatibility, camptothecin, kinase inhibitors, anticancer agents, polymer surface modification
MeSH terms
Absorption, Antineoplastic Agents, Phytogenic, Biocompatible Materials, Camptothecin, Cell Line, Dimethylpolysiloxanes, Fibroblasts, Humans, Oxygen, Permeability, Cell Culture Techniques, Phase Transition, Microfluidic Analytical Techniques, Protein Kinase Inhibitors, Cell Proliferation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.