Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications
Open accessThe DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
Poly(dimethyl siloxane) (PDMS)-based microfluidic devices are now commonly used for a wide variety of biological experiments, including cell culture assays. However, the porous, hydrophobic polymer matrix of PDMS rapidly absorbs small hydrophobic molecules, including hormones and most small-molecule drugs. This makes it challenging to perform experiments that require such substances in PDMS microfluidic devices. This study presents evidence that a sol-gel treatment of PDMS that fills the polymer matrix with silica nanoparticles is effective at reducing the absorption of drugs into the material while preserving its biocompatibility, transparency, and oxygen permeability. We show that the absorption of two anticancer drugs, camptothecin and a kinase inhibitor, is reduced to such an extent that on-chip microfluidic cell culture experiments can recapitulate the results obtained off-chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although PDMS holds many favorable properties for manufacturing microfluidic organ devices, it also has the potential drawback of adsorbing small and hydrophobic molecules.61, 62”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [62]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationPDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Self-citationBiological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Pillai, O., & Panchagnula, R. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00227-1 · Cited by 710
Versatile, Fully Automated, Microfluidic Cell Culture System
Gómez-Sjöberg, R., Leyrat, A. A., Pirone, D. M., Chen, C. S., & Quake, S. R. (2007) · Analytical Chemistry · doi:10.1021/ac071311w · Cited by 625
Self-citationSurface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Mukhopadhyay, R. (2007) · Analytical Chemistry · doi:10.1021/ac071903e · Cited by 355
Cited by
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“Hydrophobic molecules, less than approximately 500 Da, are absorbed into PDMS (Gomez-Sjoberg et al., 2010), which complicates the interpretation of some studies.”
BackgroundSelf-citationMicrofabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
“These coatings have been reported to be biocompatible [16], but the presence of cells on compound absorption or coating degradation has not been investigated.”
BackgroundMehling, M., & Tay, S. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.10.005 · Cited by 390
Lee, H., & Cho, D.-W. (2016) · Lab on a Chip · doi:10.1039/c6lc00450d · Cited by 363
Gökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Pumps for microfluidic cell culture
Byun, C. K., Abi‐Samra, K., Cho, Y., & Takayama, S. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300205 · Cited by 187
Gokaltun, A., Yarmush, M. L., Asatekin, A., & Usta, O. B. (2017) · TECHNOLOGY · doi:10.1142/s2339547817300013 · Cited by 183
Multiorgan Microphysiological Systems for Drug Development: Strategies, Advances, and Challenges
Wang, Y. I., Carmona, C., Hickman, J. J., & Shuler, M. L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701000 · Cited by 167
Cardoso, B. D., Castanheira, E. M. S., Lanceros‐Méndez, S., & Cardoso, V. F. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202936 · Cited by 161
Lane, K. M., Valen, D. V., DeFelice, M. M., Macklin, D. N., Kudo, T., Jaimovich, A., Carr, A., Meyer, T., Pe’er, D., Boutet, S. C., et al. (2017) · Cell Systems · doi:10.1016/j.cels.2017.03.010 · Cited by 163
Patient-derived pancreatic cancer-on-a-chip recapitulates the tumor microenvironment
Haque, M. R., Wessel, C. R., Leary, D. D., Wang, C., Bhushan, A., & Bishehsari, F. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00370-6 · Cited by 137
Shi, M., Majumdar, D., Gao, Y., Brewer, B. M., Goodwin, C. R., McLean, J. A., Li, D., & Webb, D. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50249j · Cited by 122
Chramiec, A., Teles, D., Yeager, K., Marturano-Kruik, A., Pak, J., Chen, T., Hao, L., Wang, M., Lock, R., Tavakol, D. N., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00424c · Cited by 113
Ongaro, A. E., Giuseppe, D. D., Kermanizadeh, A., Crespo, A. M., Mencattini, A., Ghibelli, L., Mancini, V., Wlodarczyk, K. L., Hand, D. P., Martinelli, E., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00651 · Cited by 105
Engineered Microsystems for Spheroid and Organoid Studies
Kang, S., Kim, D., Lee, J., Takayama, S., & Park, J. Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001284 · Cited by 100
Recent developments in microfluidic large scale integration
Araci, I. E., & Brisk, P. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.08.014 · Cited by 98
Benchtop micromolding of polystyrene by soft lithography
Wang, Y., Balowski, J., Phillips, C., Phillips, R., Sims, C. E., & Allbritton, N. L. (2011) · Lab on a Chip · doi:10.1039/c1lc20281b · Cited by 90
Zhou, Y., Shen, J. X., & Lauschke, V. M. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2019.01093 · Cited by 85
Cycloheximide can distort measurements of mRNA levels and translation efficiency
Santos, D. A., Shi, L., Tu, B. P., & Weissman, J. S. (2019) · Nucleic Acids Research · doi:10.1093/nar/gkz205 · Cited by 78
Nguyen, T., Jung, S. H., Lee, M. S., Park, T.-E., Ahn, S.-K., & Kang, J. H. (2019) · Lab on a Chip · doi:10.1039/c9lc00338j · Cited by 77
Simple replica micromolding of biocompatible styrenic elastomers
Borysiak, M. D., Bielawski, K. S., Sniadecki, N. J., Jenkel, C. F., Vogt, B. D., & Posner, J. D. (2013) · Lab on a Chip · doi:10.1039/c3lc50426c · Cited by 71
Kumar, V., & Varghese, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801198 · Cited by 68
Self-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
Glass-based organ-on-a-chip device for restricting small molecular absorption
Hirama, H., Satoh, T., Sugiura, S., Shin, K., Onuki-Nagasaki, R., Kanamori, T., & Inoue, T. (2018) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2018.10.019 · Cited by 64
Recent advances in microfluidic technology and applications for anti-cancer drug screening
Shi, Y., Cai, Y., Cao, Y., Hong, Z., & Chai, Y. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116118 · Cited by 63
Liver-on-a-chip devices: the pros and cons of complexity
Dalsbecker, P., Adiels, C. B., & Goksör, M. (2022) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00346.2021 · Cited by 64
Liver and kidney cells cultures in a new perfluoropolyether biochip
Jellali, R., Paullier, P., Fleury, M., & Leclerc, É. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.141 · Cited by 58
Müller, B., Sulzer, P., Walch, M., Zirath, H., Buryška, T., Rothbauer, M., Ertl, P., & Mayr, T. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129664 · Cited by 59
Beal, J. H. L., Bubendorfer, A., Kemmitt, T., Hoek, I., & Arnold, W. M. (2012) · Biomicrofluidics · doi:10.1063/1.4740232 · Cited by 50
Biomimetic models of the glomerulus
Valverde, M. G., Mille, L. S., Figler, K. P., Cervantes, E., Li, V. Y., Bonventre, J. V., Masereeuw, R., & Zhang, Y. S. (2022) · Nature Reviews Nephrology · doi:10.1038/s41581-021-00528-x · Cited by 57
Testing Aβ toxicity on primary CNS cultures using drug-screening microfluidic chips
Ruiz, A., Joshi, P., Mastrangelo, R., Francolini, M., Verderio, C., & Matteoli, M. (2014) · Lab on a Chip · doi:10.1039/c4lc00174e · Cited by 56
Viable cell culture in PDMS-based microfluidic devices
Tanyeri, M., & Tay, S. (2018) · Methods in cell biology · doi:10.1016/bs.mcb.2018.09.007 · Cited by 62
“…materials such as parylene and wax (Ren et al., 2010; Sasaki et al., 2010), pretreatment of surfaces with sol-gel methods (Abate et al., 2008; Gomez-Sjoberg et al., 2010; Orhan et al., 2008), polymer films (Ausri et al., 2018; Patel, Choi, & Meng, 2010), and surfactants such as pluronic (Wu,…”
MethodFabrication and bonding of thiol-ene-based microfluidic devices
Sikanen, T. M., Lafleur, J., Moilanen, M.-E., Zhuang, G., Jensen, T. G., & Kutter, J. P. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/3/037002 · Cited by 48
Organ‐on‐a‐Chip Systems for Women's Health Applications
Nawroth, J. C., Rogal, J., Weiß, M., Brucker, S. Y., & Loskill, P. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700550 · Cited by 47
Sorption of Neuropsychopharmaca in Microfluidic Materials for In Vitro Studies
Winkler, T. E., & Herland, A. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c07639 · Cited by 38
Compound Absorption in Polymer Devices Impairs the Translatability of Preclinical Safety Assessments
Kemas, A. M., Shafagh, R. Z., Taebnia, N., Michel, M., Preiss, L. C., Hofmann, U., & Lauschke, V. M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202303561 · Cited by 45
Abouhagger, A., Celiešiūtė-Germanienė, R., Bakute, N., Stirke, A., & Melo, W. C. M. A. (2024) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2024.1419570 · Cited by 36
Bajaj, P., Harris, J. F., Huang, J., Nath, P., & Iyer, R. S. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00480 · Cited by 37
A drug-compatible and temperature-controlled microfluidic device for live-cell imaging
Chen, T., Gómez‐Escoda, B., Muñoz-García, J., Babic, J., Griscom, L., Wu, P.-Y. J., & Coudreuse, D. Y. M. (2016) · Open Biology · doi:10.1098/rsob.160156 · Cited by 34
Weeks, J. C., Robinson, K. J., Lockery, S. R., & Roberts, W. M. (2018) · International Journal for Parasitology Drugs and Drug Resistance · doi:10.1016/j.ijpddr.2018.10.003 · Cited by 35
Rodrigues, P. M., Xavier, M., Calero, V., Pastrana, L. M., & Gonçalves, C. (2022) · Micromachines · doi:10.3390/mi13050713 · Cited by 33
“Methylamine and other contaminants introduced by the sol–gel treatment were eliminated from the bulk by further immersion in deionised water for 24 h (with the water changed 2×), which was shown to improve the biocompatibility of the elastomer [37].”
BackgroundResultMair, D. B., Williams, M. A. C., Chen, J. F., Goldstein, A. J., Wu, A., Lee, P. H. U., Sniadecki, N. J., & Kim, D. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c10669 · Cited by 33
Nishikawa, M., Ito, H., Tokito, F., Hirono, K., Inamura, K., Scheidecker, B., Danoy, M., Kawanishi, T., Arakawa, H., Kato, Y., et al. (2022) · Frontiers in Toxicology · doi:10.3389/ftox.2022.810478 · Cited by 30
“They also showed that the oxygen permeability did not change before and after treatment (Gomez-Sjoberg et al., 2010).”
BackgroundTähkä, S. M., Bonabi, A., Nordberg, M.-E., Kanerva, M., Jokinen, V. P., & Sikanen, T. M. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.11.072 · Cited by 25
Microfluidic Platforms to Unravel Mysteries of Alzheimer’s Disease: How Far Have We Come?
Prasanna, P., Rathee, S., Rahul, V., Mandal, D., Goud, M. S. C., Yadav, P., Hawthorne, S. J., Sharma, A., Gupta, P. K., Ojha, S. K., et al. (2021) · Life · doi:10.3390/life11101022 · Cited by 28
Hu, W., Wang, Y., Han, J., Zhang, W., Chen, J., Li, X., & Wang, L. (2025) · Biomaterials Science · doi:10.1039/d4bm01273a · Cited by 30
Malijauskaite, S., Connolly, S. A., Newport, D. T., & McGourty, K. (2021) · Cytokine & Growth Factor Reviews · doi:10.1016/j.cytogfr.2021.03.002 · Cited by 29
Tähkä, S. M., Bonabi, A., Jokinen, V. P., & Sikanen, T. M. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.03.018 · Cited by 23
Lopa, S., Piraino, F., Kemp, R. J., Di, C., Lovati, A. B., Giancamillo, A. D., Moroni, L., Peretti, G. M., Rasponi, M., & Moretti, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25557 · Cited by 28
“However, to minimize possible biological bias, which may be particularly relevant in studies evaluating the paracrine interaction between multiple cell types, treatments developed to prevent nonspecific molecule absorption/adsorption in PDMS could also be applied [Gomez-Sjoberg et al., 2010; Harris et al., 2011; Huang…”
BackgroundAymerich, M., Gomez-Varela, A. I., Álvarez, E., & Flores-Arias, M. T. (2016) · Materials · doi:10.3390/ma9090728 · Cited by 22
“The biocompatibility of each coating is evaluated in order to find the most suitable sol-gel coating that reduces the deterioration of the PDMS [26,27] as well as to present the best environment for endothelial cells to attach and spread.”
BackgroundFacile Macrocyclic Polyphenol Barrier Coatings for PDMS Microfluidic Devices
Reese, W. M., Burch, P., Korpusik, A. B., Liu, S. E., Loskill, P., Messersmith, P. B., & Healy, K. E. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202001274 · Cited by 20
Lung on a Chip Development from Off-Stoichiometry Thiol–Ene Polymer
Rimša, R., Galvanovskis, A., Plūme, J., Rūmnieks, F., Grindulis, K., Paidere, G., Erentraute, S., Mozoļevskis, G., & Ābols, A. (2021) · Micromachines · doi:10.3390/mi12050546 · Cited by 19
“Parylene [27], sol–gel-based silica nanoparticles [28], and Cellbinder [25] have been reported as promising coatings to reduce PDMS absorption of small, fat-soluble molecules.”
BackgroundLee, J.-B., Kim, H., Kim, S., & Sung, G. Y. (2022) · Micromachines · doi:10.3390/mi13111932 · Cited by 17
“This limits their use in some biological applications, including cell culture experiments that require drugs with intracellular targets [15].”
BackgroundHuyen, L. T. N., Hong, S. J., Trung, T. Q., Meeseepong, M., Kim, A. R., & Lee, N. (2023) · BioChip Journal · doi:10.1007/s13206-023-00096-1 · Cited by 17
“These methods can increase the surface energy of PDMS but are still limited by chemical stability, haze [16], changes of mechanical properties [17], and difficulty in obtaining long-term hydrophilic properties due to the mobility of polymer chains in PDMS [18].”
Ratri, M. C., Brilian, A. I., Setiawati, A., Nguyen, H. T., Soum, V., & Shin, K. (2021) · Advanced NanoBiomed Research · doi:10.1002/anbr.202000088 · Cited by 20
Hahnel, S. R., Roberts, W. M., Heisler, I., Kulke, D., & Weeks, J. C. (2021) · International Journal for Parasitology Drugs and Drug Resistance · doi:10.1016/j.ijpddr.2021.05.005 · Cited by 19
“It is possible to reduce or eliminate the issue of PDMS absorption by pre-treating microchannels with particular chemical agents, or fabricating chips out of plastic or glass (Gomez-Sjoberg et al., 2010; Ren et al., 2011; Hirama et al. 2018; Gökaltun et al., 2019), which we did not explore in the present experiments.”
BackgroundIntestinal Permeability of Drugs in Caco-2 Cells Cultured in Microfluidic Devices
Sasaki, Y., Tatsuoka, H., Tsuda, M., Sumi, T., Eguchi, Y., So, K., Higuchi, Y., Takayama, K., Torisawa, Y., & Yamashita, F. (2022) · Biological and Pharmaceutical Bulletin · doi:10.1248/bpb.b22-00092 · Cited by 16
Lenhart, A. E., & Kennedy, R. T. (2023) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00025 · Cited by 13
Gáspár, A., & Gomez, F. A. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.03.035 · Cited by 12
Targeted Cancer Therapy‐on‐A‐Chip
Abed, H., Radha, R., Anjum, S., Paul, V., AlSawaftah, N., Pitt, W. G., Ashammakhi, N. A., & Husseini, G. A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202400833 · Cited by 13
A microfluidic platform for culturing and high-content imaging of adult stem cell-derived organoids
Moshksayan, K., Khanna, R., Camli, B., Yakay, Z. N., Harihara, A., Zdyrski, C., Mondal, S., Hegarty, E., Mochel, J. P., Allenspach, K., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-23883-2 · Cited by 14
A novel method of cell culture based on the microfluidic chip for regulation of cell density
Zhang, F., Zhang, R., Wei, M., & Zhang, Y. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27614 · Cited by 11
Mou, Z., Qi, X., Liu, R., Zhang, J., & Zhang, Z. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.04.041 · Cited by 11
Amphiphilic silicones to reduce the absorption of small hydrophobic molecules
Quiñones-Pérez, M., Cieza, R. J., Ngo, B. K. D., Grunlan, M. A., & Domenech, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.11.041 · Cited by 12
High-Throughput Co-Culture System for Analysis of Spatiotemporal Cell-Cell Signaling
Son, M., Wang, A. G., Kenna, E., & Tay, S. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115089 · Cited by 12
Bisconti, F., Abreu, H., Nguyen, T. D., Stolfi, F., Corbezzolo, N., Gigli, G., Raineri, D., Cappellano, G., Polini, A., Gervaso, F., et al. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1712796 · Cited by 9
Surface Functionalization of Microfluidic Devices
Eichler, M., Klages, C. ‐., & Lachmann, K. (2016) · Springer eBooks · doi:10.1007/978-3-319-26920-7_3 · Cited by 10
Ratri, M. C., Brilian, A. I., Setiawati, A., Nguyen, H. T., Soum, V., & Shin, K. (2021) · Advanced NanoBiomed Research · doi:10.1002/anbr.202170053 · Cited by 11
Gan, F., Wang, J., Wen, J., Zhou, J., Mo, J., Han, S., Wu, Y., & Yi, N. (2022) · Polymer Testing · doi:10.1016/j.polymertesting.2022.107615 · Cited by 9
Lung-on-a-chip platforms for modeling disease pathogenesis
Dellaquila, A., Thomée, E., McMillan, A. H., & Lesher‐Pérez, S. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00004-8 · Cited by 12
Microfluidic devices, accumulation of endogenous signals and stem cell fate selection
Fattahi, P., Haque, A., Son, K. J., Guild, J., & Revzin, A. (2019) · Differentiation · doi:10.1016/j.diff.2019.10.005 · Cited by 8
Hawkins, J., Miao, X., Cui, W., & Sun, Y. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2021.0929 · Cited by 7
Microfluidic perfusion modulates growth and motor neuron differentiation of stem cell aggregates
Jackson, E., Schaefer, A. W., McDevitt, T. C., & Lu, H. (2020) · The Analyst · doi:10.1039/d0an00491j · Cited by 9
Dewhurst, R. M., Molinari, E., & Sayer, J. A. (2023) · Microfluidics and Nanofluidics · doi:10.1007/s10404-023-02629-4 · Cited by 9
Gomez-Varela, A. I., Aymerich, M., Nieto, D., Castro, Y., Beule, P. D., Álvarez, E., Bao, C., & Flores-Arias, M. T. (2017) · InTech eBooks · doi:10.5772/67830 · Cited by 5
“This procedure provides the structure with the chemical robustness of the glass and preserves the biocompatibility and transparency properties without significantly altering the geometry of the PDMS device [26, 27].”
BackgroundMicrophysiological system with integrated sensors to study the effect of pulsed electric field
Bakute, N., Andriukonis, E., Kasperaviciute, K., Dobilas, J., Šapurov, M., Mozoļevskis, G., & Stirkė, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-69693-w · Cited by 5
In situ formation and culture of cell spheroids in a low-binding 3D-printed biochip
Martins, A., Klieber, S., Graët, C. L., Leclerc, É., Legallais, C., & Jellali, R. (2025) · Lab on a Chip · doi:10.1039/d5lc00503e · Cited by 4
Advanced technologies of artery-on-a-chip: a review of construction strategies and disease models
Chang, S.-Q., Qiao, L., Abodunrin, O. D., Zou, L., & Huang, N. (2026) · Angiogenesis · doi:10.1007/s10456-026-10030-2 · Cited by 3
“Its softness may lead to channel collapse, and its porosity can absorb hydrophobic small molecules such as biomolecules and drugs (MW ∼ 500 Da) [47, 48], potentially introducing experimental bias in studies of cell signaling and drug dose-response.”
Mirzababaei, S., Nigjeh, M. N., Abdollahi, M. R., & Shamloo, A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823536-2.00011-0 · Cited by 4
Microfluidic devices and their applicability to cell studies
Fernandes, A. C., Semenova, D., & Grundtvig, I. P. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822482-3.00003-8 · Cited by 2
Joint Cartilage Tissue Engineering and Pre-Clinical Safety and Efficacy Testing
Thomas, G., Moroni, L., Leysi-Derilou, Y., & Lise, C. (2011) · InTech eBooks · doi:10.5772/24096 · Cited by 5
“However, one of the challenges is absorption of small hydrophobic molecules, typically hormones, by the plastic used for producing the microchips (Gomez-Sjoberg et al., 2010).”
BackgroundHydroxyapatite nanoparticle films with designed nanostructures for advanced cell culture
Liu, Z., Noda, D., Shi, W., Galindo, T. G. P., Otsuka, Y., & Tagaya, M. (2025) · Nanoscale · doi:10.1039/d5nr02718g · Cited by 2
Maskell, K. G., Cook, A. L., King, A. E., Dickson, T. C., & Blizzard, C. L. (2026) · Lab on a Chip · doi:10.1039/d5lc00577a · Cited by 3
Mika, T., Kalniņš, M., & Spalviņš, K. (2024) · Biology Methods and Protocols · doi:10.1093/biomethods/bpae049 · Cited by 2
In vitro three-dimensional cancer metastasis modeling: Past, present, and future
Han, W., Yuan, W., Zhu, J., Fan, Q., Qu, J., & Liu, L. (2016) · Chinese Physics B · doi:10.1088/1674-1056/25/1/018709 · Cited by 2
“Lung-on-a-chip” as an instrument for studying the pathophysiology of human respiration
Zhukova, O. A., Ozerskaya, I. V., Basmanov, D. V., Stolyarov, V. Y., Bogush, V. G., Kolesov, V. V., Zykov, K. A., Yusubalieva, G. M., & Baklaushev, V. P. (2024) · Journal of clinical practice · doi:10.17816/clinpract637140 · Cited by 1
Note: A single-chamber tool for plasma activation and surface functionalization in microfabrication
Bowman, A. J., Scherrer, J. R., & Reiserer, R. S. (2015) · Review of Scientific Instruments · doi:10.1063/1.4922827 · Cited by 1
IPSC-derived intestinal organoids and current 3D intestinal scaffolds
Malijauskaite, S., Mulvihill, J. J., Grabrucker, A. M., & McGourty, K. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823809-7.00011-6 · Cited by 1
Microfluidic Culture Platforms in Neuroscience Research
Pham, V. M., Ha, H., & Thakor, N. V. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_128-2 · Cited by 1
Krejci, I., Piana, C., Howitz, S., Wegener, T., Fiedler, S., Zwanzig, M., Schmitt, D., Schneider‐Daum, N., Meier, K., Lehr, C., et al. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.08.031
The Developing Status of High-Throughput Drug Screening Microfluidic Chip by FRET on Medicine
Zhang, X. Y., Huang, Q. H., Yang, M. J., Liao, X. L., Shao, Z., Huang, J. X., Xu, W. F., & Hu, X. (2018) · Materials science forum · doi:10.4028/www.scientific.net/msf.914.19
Microsystems technology for high-throughput single-cell sorting
Piraino, L. R., Conti, T., Sharipol, A., Benoit, D. S. W., & DeLouise, L. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102420-1.00034-0
Advancing Microfluidic Assays toward Personalized Multiple Myeloma Cancer Therapy Selection
Moore, T. A. (2018) · TSpace (University of Toronto) · Cited by 1
Microfluidic Culture Platforms in Neuroscience Research
Pham, V. M., Ha, H., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_128
Transforming Drug Discovery with Miniaturized Predictive Tissue Models
Akbari, M. (2025) · Micromachines · doi:10.3390/mi16030299 · Cited by 1
“However, a significant drawback of PDMS is its tendency to absorb small hydrophobic molecules rapidly, leading to the unintended diffusion and loss of these molecules into the material [18].”
New microfluidic systems for controlling the cell microenvironment during live-cell imaging
Babic, J. (2017) · theses.fr (ABES) · doi:10.70675/04bd07d1z3432z4763z8f11z544747af5ee0
Yan, L. (2026) · Advances in Clinical Medicine · doi:10.12677/acm.2026.1641743
Mandal, S. K., Kumar, R., Kumar, D., & Pradhan, A. R. (2026) · Polymer Engineering and Science · doi:10.1002/pen.70819
Metadata
- Authors
- Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R.
- Affiliations
- Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States, Department of Bioengineering and Howard Hughes Medical Institute, Stanford University, Stanford, California 94305, United States, Department of Anesthesia and Perioperative Care, San Francisco General Hospital, San Francisco, California 94143, United States, and Department of Cellular and Molecular Pharmacology and Howard Hughes Medical Institute, University of California San Francisco, San Francisco,...
- San Francisco General Hospital (US)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-11
- Volume
- 82
- Issue
- 21
- Pages
- 8954-8960
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC3032040
- OpenAlex
- W1964121777
- Cited by
- 104
- References
- 24
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 11 · 2021: 10 · 2020: 8 · 2019: 7 · 2018: 7 · 2017: 8 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 8 · 2012: 2
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Howard Hughes Medical Institute
- Mount Zion Health Fund
- National Institutes of Health (DP1OD000251)
- University of California, San Francisco
- National Cancer Institute
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- polydimethylsiloxane, sol-gel treatment, silica nanoparticles, drug absorption, microfluidic cell culture, biocompatibility, camptothecin, kinase inhibitors, anticancer agents, polymer surface modification
- MeSH terms
- Absorption, Antineoplastic Agents, Phytogenic, Biocompatible Materials, Camptothecin, Cell Line, Dimethylpolysiloxanes, Fibroblasts, Humans, Oxygen, Permeability, Cell Culture Techniques, Phase Transition, Microfluidic Analytical Techniques, Protein Kinase Inhibitors, Cell Proliferation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.