Potentiometric Strip Cell Based on Carbon Nanotubes as Transducer Layer: Toward Low-Cost Decentralized Measurements
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this study, we developed a potentiometric planar strip cell based on single-walled carbon nanotubes that aims to exploit the attributes of solid-contact ion-selective electrodes for decentralized measurements. That is, the ion-selective and reference electrodes have been simultaneously miniaturized onto a plastic planar substrate by screen-printing and drop-casting techniques, obtaining disposable strip cells with satisfactory performance characteristics (i.e., the sensitivity is 57.4 ± 1.3 mV/dec, the response time is ≤30 s within the linear range from log a(K+) = -5 to -2, and the limit of detection is -6.5), no need of maintenance during long dry storage, quick signal stabilization, and light insensitivity in short-term measurements. We also show how the new potentiometric strip cell makes it possible to perform decentralized and rapid determinations of ions in real samples, such as saliva or beverages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saliva specimen: A new laboratory tool for diagnostic and basic investigation
Chiappin, S., Antonelli, G., Gatti, R., & De Palo, E. F. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.04.011 · Cited by 828
Bobacka, J. (1999) · Analytical Chemistry · doi:10.1021/ac990497z · Cited by 686
Cited by
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Shao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A potentiometric tattoo sensor for monitoring ammonium in sweat
Guinovart, T., Bandodkar, A. J., Windmiller, J. R., Andrade, F. J., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01672b · Cited by 343
Electrochemical determination of glutathione: a review
Harfield, J. C., Batchelor-McAuley, C., & Compton, R. G. (2012) · The Analyst · doi:10.1039/c2an35090d · Cited by 222
Metadata
- Authors
- Rius-Ruiz, F. X., Crespo, G. A., Bejarano-Nosas, D., Blondeau, P., Riu, J., & Rius, F. X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-21
- Volume
- 83
- Issue
- 22
- Pages
- 8810-8815
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2312617119
- Cited by
- 108
- References
- 2
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.