CoChat

Fast Top-Down Intact Protein Characterization with Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry

Open access
Sun, Liangliang, Knierman, Michael D., Zhu, Guijie, Dovichi, Norman J. · 2013 · Analytical Chemistry
Cited by 65

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Capillary zone electrophoresis (CZE)-electrospray ionization tandem mass spectrometry (ESI-MS/MS) was applied for rapid top-down intact protein characterization. A mixture containing four model proteins (cytochrome c, myoglobin, bovine serum albumin (BSA), and β-casein) was used as the sample. The CZE-ESI-MS system was first evaluated with the mixture. The four model proteins and five impurities were baseline-separated within 12 min. The limits of detection [signal-to-noise ratio (S/N) = 3] of the four model proteins ranged from 20 (cytochrome c) to 800 amol (BSA). The relative standard deviations of migration time and intensity for the four model proteins were less than 3% and 30%, respectively, in quintuplicate runs. CZE-ESI-MS/MS was then applied for top-down characterization of the mixture. Three of the model proteins (all except BSA) and an impurity (bovine transthyretin) were confidently identified by database searching of the acquired tandem spectra from protein fragmentation. Modifications including phosphorylation, N-terminal acetylation, and heme group binding were identified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac4008122

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 65

Metadata

Authors
Sun, L., Knierman, M. D., Zhu, G., & Dovichi, N. J.
Venue
Analytical Chemistry
Published
2013-06-07
Volume
85
Issue
12
Pages
5989-5995
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1974313253
Cited by
65
References
8
FWCI
4.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fast Top-Down Intact Protein Characterization with Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac4008122
The paper
Sun, L., Knierman, M. D., Zhu, G., & Dovichi, N. J. (2013). Fast Top-Down Intact Protein Characterization with Capillary Zone Electrophoresis–Electrospray Ionization Tandem Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac4008122

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.