Ultraviolet Photodissociation for Characterization of Whole Proteins on a Chromatographic Time Scale
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Intact protein characterization using mass spectrometry thus far has been achieved at the cost of throughput. Presented here is the application of 193 nm ultraviolet photodissociation (UVPD) for top down identification and characterization of proteins in complex mixtures in an online fashion. Liquid chromatographic separation at the intact protein level coupled with fast UVPD and high-resolution detection resulted in confident identification of 46 unique sequences compared to 44 using HCD from prepared Escherichia coli ribosomes. Importantly, nearly all proteins identified in both the UVPD and optimized HCD analyses demonstrated a substantial increase in confidence in identification (as defined by an average decrease in E value of ∼40 orders of magnitude) due to the higher number of matched fragment ions. Also shown is the potential for high-throughput characterization of intact proteins via liquid chromatography (LC)-UVPD-MS of molecular weight-based fractions of a Saccharomyces cerevisiae lysate. In total, protein products from 215 genes were identified and found in 292 distinct proteoforms, 168 of which contained some type of post-translational modification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
Self-citationA Multidimensional Chromatography Technology for In-depth Phosphoproteome Analysis
Albuquerque, C. P., Smolka, M. B., Payne, S. H., Bafna, V., Eng, J., & Zhou, H. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700468-mcp200 · Cited by 504
Complete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Self-citationExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Self-citationProtein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
Cited by
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Self-citationPhotodissociation mass spectrometry: new tools for characterization of biological molecules
Brodbelt, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60444f · Cited by 322
Self-citationUltraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules
Brodbelt, J. S., Morrison, L. J., & Santos, I. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00440 · Cited by 295
Self-citationBelov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
“coli ribosomal protein extract via nanoLC-MS conducted under denaturing separation conditions [43].”
InfluentialCleland, T. P., DeHart, C. J., Fellers, R. T., VanNispen, A. J., Greer, J. B., LeDuc, R. D., Parker, W. R., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00043 · Cited by 96
Self-citationAnderson, L. C., DeHart, C. J., Kaiser, N. K., Fellers, R. T., Smith, D. F., Greer, J. B., LeDuc, R. D., Blakney, G. T., Thomas, P. M., Kelleher, N. L., et al. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00696 · Cited by 94
Self-citationpTop 1.0: A High-Accuracy and High-Efficiency Search Engine for Intact Protein Identification
Sun, R.-X., Luo, L., Wu, L., Wang, R.-M., Zeng, W.-F., Chi, H., Liu, C., & He, S.-M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03963 · Cited by 71
Riley, N. M., Sikora, J. W., Seckler, H. S., Greer, J. B., Fellers, R. T., LeDuc, R. D., Westphall, M. S., Thomas, P. M., Kelleher, N. L., & Coon, J. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01638 · Cited by 43
Self-citation
Metadata
- Authors
- Cannon, J. R., Cammarata, M. B., Robotham, S. A., Cotham, V. C., Shaw, J. B., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-29
- Volume
- 86
- Issue
- 4
- Pages
- 2185-2192
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2032372830
- Cited by
- 92
- References
- 6
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.