Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Metabolic Profiling of Bile Acids in Human and Mouse Blood by LC–MS/MS in Combination with Phospholipid-Depletion Solid-Phase Extraction

Han, Jun, Liu, Yang, Wang, Renxue, Yang, Juncong, Ling, Victor, Borchers, Christoph H.·2015·Analytical Chemistry

Abstract

To obtain a more comprehensive profile of bile acids (BAs) in blood, we developed an ultrahigh performance liquid chromatography/multiple-reaction monitoring-mass spectrometry (UPLC-MRM-MS) method for the separation and detection of 50 known BAs. This method utilizes phospholipid-depletion solid-phase extraction as a new high-efficiency sample preparation procedure for BA assay. UPLC/scheduled MRM-MS with negative ion electrospray ionization enabled targeted quantitation of 43 and 44 BAs, respectively, in serum samples from seven individuals with and without fasting, as well as in plasma samples from six cholestatic gene knockout mice and six age- and gender-matched wild-type (FVB/NJ) animals. Many minor BAs were identified and quantitated in the blood for the first time. Method validation indicated good quantitation precision with intraday and interday relative standard deviations of ≤9.3% and ≤10.8%, respectively. Using a pooled human serum sample and a pooled mouse plasma sample as the two representative test samples, the quantitation accuracy was measured to be 80% to 120% for most of the BAs, using two standard-substance spiking approaches. To profile other potential BAs not included in the 50 known targets from the knockout versus wild-type mouse plasma, class-specific precursor/fragment ion transitions were used to perform UPLC-MRM-MS for untargeted detection of the structural isomers of glycine- and taurine-conjugated BAs and unconjugated tetra-hydroxy BAs. As a result, as many as 36 such compounds were detected. In summary, this UPLC-MRM-MS method has enabled the quantitation of the largest number of BAs in the blood thus far, and the results presented have revealed an unexpectedly complex BA profile in mouse plasma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac503816u

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 188

Metadata

Authors
Han, J., Liu, Y., Wang, R., Yang, J., Ling, V., & Borchers, C. H.
Venue
Analytical Chemistry
Published
2014-12-24
Volume
87
Issue
2
Pages
1127-1136
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2326819017
Cited by
188
References
3
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metabolic Profiling of Bile Acids in Human and Mouse Blood by LC–MS/MS in Combination with Phospholipid-Depletion Solid-Phase Extraction. https://app.cochat.ai/papers/10.1021/ac503816u
The paper
Han, J., Liu, Y., Wang, R., Yang, J., Ling, V., & Borchers, C. H. (2015). Metabolic Profiling of Bile Acids in Human and Mouse Blood by LC–MS/MS in Combination with Phospholipid-Depletion Solid-Phase Extraction. Analytical Chemistry. https://doi.org/10.1021/ac503816u

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.