Multiplexed Size Separation of Intact Proteins in Solution Phase for Mass Spectrometry
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Reliable size-based protein separation is an invaluable biological technique. Unfortunately, size separation in solution is underutilized, owing perhaps to the poor resolution of conventional techniques. Here, we report an enhanced multiplexed GELFrEE (gel-eluted liquid fraction entrapment electrophoresis) device which incorporates eight independent separation channels, operating with high repeatability. This enables simultaneous size separation of independent proteome samples, each into 16 well resolved liquid fractions, covering 10-150 kDa in 1.5 h. A novel strategy to increase sample loads while maintaining electrophoretic resolution is presented by distributing the sample among the eight channels with subsequent pooling of collected fractions. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of the S. cerevisiae proteome following GELFrEE separation and sodium dodecyl sulfate (SDS) removal demonstrates the resolution and high correlation achieved between molecular weight and fraction number for the identified proteins. This device is highly orthogonal to solution isoelectric focusing, enabling our disclosure of a fully multiplexed high-throughput two-dimensional liquid electrophoretic (2D LE) platform that separates analogously to 2D polyacrylamide gel electrophoresis (PAGE). With 2D LE, a total of 128 well-resolved liquid fractions are obtained from 1 mg of S. cerevisiae proteins covering ranges 3.8 < pI < 7.8 and 10 kDa < MW < 150 kDa in an unprecedented 3.25 h total separation time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Tran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206
Self-citationProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Cited by
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
“This procedure for two-dimensional liquid electrophoresi”
Self-citationProgress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“It was shown that the device could be used as a first dimension of separation prior to a multiplexed version of GELFrEE, analogous to a twodimensional gel separation [55].”
MethodBest practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“Finally, more efficient protein extraction, separation, and fractionation methods were critical prerequisites for an in-depth analysis of complex samples by top-down MS (Sharma et al , 2007; Chen et al , 2008; Tran & Doucette, 2009; Han et al , 2014b).”
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Top-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
“Notably, the development of Gel-Eluted Liquid Fraction Entrapment Electrophoresis (GELFrEE) has allowed for multiplexed, high-resolution size-based separation of intact proteins [30,40].”
BackgroundKellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Self-citationTakemori, A., Butcher, D. S., Harman, V. M., Brownridge, P., Shima, K., Higo, D., Ishizaki, J., Hasegawa, H., Suzuki, J., Yamashita, M., et al. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00303 · Cited by 90
Evaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
Ahlf, D. R., Compton, P. D., Tran, J. C., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3004216 · Cited by 89
Self-citationA comprehensive pipeline for translational top-down proteomics from a single blood draw
Toby, T. K., Fornelli, L., Srzentić, K., DeHart, C. J., Levitsky, J., Friedewald, J., & Kelleher, N. L. (2019) · Nature Protocols · doi:10.1038/s41596-018-0085-7 · Cited by 86
Doucette, A. A., Vieira, D. B., Orton, D. J., & Wall, M. J. (2014) · Journal of Proteome Research · doi:10.1021/pr500864a · Cited by 63
Self-citationThe benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Self-citationTop-Down Proteomics Identifies Plasma Proteoform Signatures of Liver Cirrhosis Progression
Forte, E., Sanders, J. M., Pla, I., Kanchustambham, V. L., Hollas, M. A. R., Huang, C.-F., Sanchez, A., Peterson, K. N., Melani, R. D., Huang, A., et al. (2024) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2024.100876 · Cited by 22
Metadata
- Authors
- Tran, J. C., & Doucette, A. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-02
- Volume
- 81
- Issue
- 15
- Pages
- 6201-6209
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2058043200
- Cited by
- 125
- References
- 5
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.