Theory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Midinfrared (IR) microspectroscopy is widely employed for spatially localized spectral analyses. A comprehensive theoretical model for the technique, however, has not been previously proposed. In this paper, rigorous theory is presented for IR absorption microspectroscopy by using Maxwell's equations to model beam propagation. Focusing effects, material dispersion, and the geometry of the sample are accounted to predict spectral response for homogeneous samples. Predictions are validated experimentally using Fourier transform IR (FT-IR) microspectroscopic examination of a photoresist. The results emphasize that meaningful interpretation of IR microspectroscopic data must involve an understanding of the coupled optical effects associated with the sample, substrate properties, and microscopy configuration. Simulations provide guidance for developing experimental methods and future instrument design by quantifying distortions in the recorded data. Distortions are especially severe for transflection mode and for samples mounted on certain substrates. Last, the model generalizes to rigorously consider the effects of focusing. While spectral analyses range from examining gross spectral features to assessing subtle features using advanced chemometrics, the limitations imposed by these effects in the data acquisition on the information available are less clear. The distorting effects are shown to be larger than noise levels seen in modern spectrometers. Hence, the model provides a framework to quantify spectral distortions that may limit the accuracy of information or present confounding effects in microspectroscopy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Saleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Optical waves in layered media
(1989) · Choice Reviews Online · doi:10.5860/choice.26-6299 · Cited by 2,173
Ordal, M. A., Long, L. L., Bell, R. J., Bell, S. E., Bell, R. R., Alexander, R. W., & Ward, C. A. (1983) · Applied Optics · doi:10.1364/ao.22.001099 · Cited by 2,136
Infrared Study of Adsorbed Molecules on Metal Surfaces by Reflection Techniques
Greenler, R. G. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726462 · Cited by 1,526
Causality and the Dispersion Relation: Logical Foundations
Toll, J. S. (1956) · Physical Review · doi:10.1103/physrev.104.1760 · Cited by 1,083
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Kramers–Kronig constrained variational analysis of optical spectra
Kuzmenko, A. B. (2005) · Review of Scientific Instruments · doi:10.1063/1.1979470 · Cited by 856
Research works printed but not linked: 2
- Born M., 1980, Principles of Optics
- Griffiths, P. R. and de Haseth, J. A.InFourier Transform Infrared Spectrometry,2nd ed.Wiley-Interscience:Hoboken, NJ, 2007; Chapter 11.1.3, pp253−255.
Cited by
Items 101–115 of 115
van Dijk, T., Mayerich, D. M., Carney, P. S., & Bhargava, R. (2013) · Frontiers in Optics · doi:10.1364/fio.2013.fth3a.2 · Cited by 2
Self-citationLarge infrared absorptance of bimaterial microcantilevers based on silicon high contrast grating
Kwon, B., Seong, M., Liu, J.-N., Rosenberger, M. R., Schulmerich, M. V., Bhargava, R., Cunningham, B. T., & King, W. P. (2013) · Journal of Applied Physics · doi:10.1063/1.4825313 · Cited by 2
Self-citationComposition-aware spectroscopic tomography
Pfister, L., Bhargava, R., Bresler, Y., & Carney, P. S. (2020) · Inverse Problems · doi:10.1088/1361-6420/abb767 · Cited by 2
Self-citationDo, M. T. (2015) · theses.fr (ABES) · doi:10.70675/bcdfc8a0zb912z40cfz828eze149b7ecb773 · Cited by 2
High-resolution infrared imaging performance of new high numerical aperture Schwarzschild objectives
Kadela, K., Oleś, H., Kosowska, K., Liberda, D., Wiatrowska, W., Cader, K., Grabowska, N., Piana, K., Tott, S., Roman, M., et al. (2025) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2025.125769 · Cited by 1
Fourier Transform Infrared (Ft-Ir) Spectroscopic Imaging for Solid Tumor Histopathology
Biswas, S., Walsh, M. J., & Bhargava, R. (2013) · Challenges and advances in computational chemistry and physics · doi:10.1007/978-94-007-7832-0_16 · Cited by 2
Self-citationInfrared Microspectroscopy of Cells and Tissue in Medical Diagnostics
Diem, M. (2015) · Wiley eBooks · doi:10.1002/9781118824924.ch13 · Cited by 1
Spectroscopy for Intact Particles
van Dijk, T., Bhargava, R., & Carney, P. S. (2012) · Imaging and Applied Optics · doi:10.1364/cosi.2012.cm4b.1
Self-citationDesign and fabrication of photonic crystal superlens for mid-infrared telescopes
Fujishiro, N. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2251391
Infrared spectroscopic imaging: a case study for digital molecular histopathology
Mittal, A., Mittal, S., Yeh, K. L., Higham, A. M., & Bhargava, R. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818870-5.00017-4 · Cited by 1
Self-citationAlavi, Z. (2020) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--34988
Characterization and optimization of coupled-wave simulations for complex heterogeneous samples
Sun, R., Reddy, R. K., & Mayerich, D. M. (2022) · Physics and simulation of optoelectronic devices. Conference · doi:10.1117/12.2609179
Translation of infrared spectroscopic imaging for digital histopathology of clinical specimens
Mittal, A. (2022) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
A linear calibration method for scattering semiconductors using the Kubelka-Munk function
Zhao, S., Luo, L., Zhang, F., Jiang, B., Jaroniec, M., & Zhang, L. (2026) · iScience · doi:10.1016/j.isci.2026.117932
Scattering correction methods of infrared spectra using graphics processing units
Imtiaz, A. (2015) · UWM Digital Commons (University of Wisconsin–Milwaukee)
Metadata
- Authors
- Davis, B. J., Carney, P. S., & Bhargava, R.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Bhargava, Rohit
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-14
- Volume
- 82
- Issue
- 9
- Pages
- 3474-3486
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980515691
- Cited by
- 115
- References
- 55
- Citations by year
- 2026: 1 · 2025: 4 · 2023: 2 · 2022: 7 · 2021: 4 · 2020: 9 · 2019: 6 · 2018: 6 · 2017: 10 · 2016: 5 · 2015: 9 · 2014: 10 · 2013: 11 · 2012: 15
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Defense
- Grainger Foundation
- Susan G. Komen
- DOD Prostate Cancer Research Program
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
- Keywords
- Maxwell's equations, focusing effect, material dispersion, spectral distortion, homogeneous samples, photoresist, substrate effects, chemometrics
- MeSH terms
- Models, Theoretical, Spectrophotometry, Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.