Size-Sorting Combined with Improved Nanocapillary Liquid Chromatography−Mass Spectrometry for Identification of Intact Proteins up to 80 kDa
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Despite the availability of ultra-high-resolution mass spectrometers, methods for separation and detection of intact proteins for proteome-scale analyses are still in a developmental phase. Here we report robust protocols for online LC-MS to drive high-throughput top-down proteomics in a fashion similar to that of bottom-up proteomics. Comparative work on protein standards showed that a polymeric stationary phase led to superior sensitivity over a silica-based medium in reversed-phase nanocapillary LC, with detection of proteins >50 kDa routinely accomplished in the linear ion trap of a hybrid Fourier transform mass spectrometer. Protein identification was enabled by nozzle-skimmer dissociation and detection of fragment ions with <10 ppm mass accuracy for highly specific database searching using tailored software. This overall approach led to identification of proteins up to 80 kDa, with 10-60 proteins identified in single LC-MS runs of samples from yeast and human cell lines prefractionated by their molecular mass using a gel-based sieving system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Self-citationTran, J. C., & Doucette, A. A. (2008) · Analytical Chemistry · doi:10.1021/ac702197w · Cited by 206
Self-citationProcessing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry
Meng, F., Cargile, B. J., Patrie, S. M., Johnson, J. R., McLoughlin, S. M., & Kelleher, N. L. (2002) · Analytical Chemistry · doi:10.1021/ac020049i · Cited by 183
Self-citation
Cited by
Mapping intact protein isoforms in discovery mode using top-down proteomics
Tran, J. C., Zamdborg, L., Ahlf, D. R., Lee, J. E., Catherman, A. D., Durbin, K. R., Tipton, J. D., Vellaichamy, A., Kellie, J. F., Li, M., et al. (2011) · Nature · doi:10.1038/nature10575 · Cited by 665
Self-citationTop Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“Polymeric reversed-phase materials, offering increased mechanical strength, uniform hydrophobicity, and high recovery, have also been utilized for the separation of intact proteins [13,22,23,24].”
BackgroundSelf-citationTop-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Deconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
“However, this situation is quickly changing with recent top-down studies of complex protein mixtures (14, 19).”
BackgroundPanchaud, A., Affolter, M., & Kussmann, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2011.12.022 · Cited by 159
“More recently, nozzleskimmer dissociation (NSD) has been shown to be powerful for the identification of proteins [47].”
BackgroundProtein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
Cai, W., Tucholski, T., Chen, B., Alpert, A. J., McIlwain, S., Kohmoto, T., Jin, S., & Ge, Y. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00380 · Cited by 135
Online Hydrophobic Interaction Chromatography–Mass Spectrometry for Top-Down Proteomics
Chen, B., Peng, Y., Valeja, S. G., Xiu, L., Alpert, A. J., & Ge, Y. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04285 · Cited by 110
Kellie, J. F., Tran, J. C., Lee, J. E., Ahlf, D. R., Thomas, H. M., Ntai, I., Catherman, A. D., Durbin, K. R., Zamdborg, L., Vellaichamy, A., et al. (2010) · Molecular BioSystems · doi:10.1039/c000896f · Cited by 99
Self-citationOptimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95
“While considerable efforts have been made to improve separation resolution and protein recovery from RPLC [3], there is a dearth of literature that details investigations of alternative separation techniques to RPLC for high-mass proteins.”
BackgroundMethodSelf-citationEvaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
Ahlf, D. R., Compton, P. D., Tran, J. C., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3004216 · Cited by 89
Self-citationHan, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77
Han, X., Wang, Y., Aslanian, A., Fonslow, B., Graczyk, B., Davis, T. N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500971h · Cited by 72
Zhao, Y., Sun, L., Champion, M. M., Knierman, M. D., & Dovichi, N. J. (2014) · Analytical Chemistry · doi:10.1021/ac500092q · Cited by 56
Capillary HILIC-MS: A New Tool for Sensitive Top-Down Proteomics
Gargano, A. F. G., Roca, L. S., Fellers, R. T., Bocxe, M., Domínguez-Vega, E., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00382 · Cited by 52
Yu, D., Wang, Z., Cupp-Sutton, K. A., Liu, X., & Wu, S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02315-2 · Cited by 39
“Several electrophoresis-based separation methods such as geleluted liquid fraction entrapment electrophoresis (GELFrEE) [26] and solution isoelectric focusing (sIEF) [27] can be applied as pre-fractionation methods for RPLC; however, these methods cannot be directly coupled to MS for detection.”
MethodLakshmanan, R., Wolff, J. J., Alvarado, R., & Loo, J. A. (2014) · PROTEOMICS · doi:10.1002/pmic.201300339 · Cited by 24
“IS fragmentation is performed without precursor-ion selection [12] and can be programed to switch between high and low energies during online protein elution [17].”
BackgroundSimone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A. (2016) · Journal of Separation Science · doi:10.1002/jssc.201500844 · Cited by 24
Metadata
- Authors
- Vellaichamy, A., Tran, J. C., Catherman, A. D., Lee, J. E., Kellie, J. F., Sweet, S. M. M., Zamdborg, L., Thomas, P. M., Ahlf, D. R., Durbin, K. R., Valaskovic, G. A., & Kelleher, N. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-14
- Volume
- 82
- Issue
- 4
- Pages
- 1234-1244
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W148173047
- Cited by
- 99
- References
- 5
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.