Cited by 77Advanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and ApplicationsMicrofluidic and Capillary Electrophoresis Applications

Sheathless Capillary Electrophoresis-Tandem Mass Spectrometry for Top-Down Characterization of Pyrococcus furiosus Proteins on a Proteome Scale

Open access
Han, Xuemei, Wang, Yueju, Aslanian, Aaron, Bern, Marshall, Lavallée-Adam, Mathieu, Yates, John R.·2014·Analytical Chemistry

Abstract

Intact protein analysis via top-down mass spectrometry (MS) provides the unique capability of fully characterizing protein isoforms and combinatorial post-translational modifications (PTMs) compared to the bottom-up MS approach. Front-end protein separation poses a challenge for analyzing complex mixtures of intact proteins on a proteomic scale. Here we applied capillary electrophoresis (CE) through a sheathless capillary electrophoresis-electrospray ionization (CESI) interface coupled to an Orbitrap Elite mass spectrometer to profile the proteome from Pyrococcus furiosus. CESI-top-down MS analysis of Pyrococcus furiosus cell lysate identified 134 proteins and 291 proteoforms with a total sample consumption of 270 ng in 120 min of total analysis time. Truncations and various PTMs were detected, including acetylation, disulfide bonds, oxidation, glycosylation, and hypusine. This is the largest scale analysis of intact proteins by CE-top-down MS to date.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac503439n

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PEI coated capillaries demonstrated high separation efficiency for protein complexes and Pyrococcus furiosus proteins via TDMS.

    “Han et al. demonstrated the high separation efficiency of PEI coated capillaries for the analysis of protein complexes and Pyrococcus furiosus proteins via TDMS59,60.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. Kelleher N. L. Anal. Chem. 2004, 76, 197A– 203A. 15190879
  2. Giometti C. S.; Tollaksen S. L.; Mukund S.; Zhi Hao Z.; Keren M.; Xuhong M.; Adams M. W. W. J. Chromatogr., A 1995, 698, 341– 349.
  3. Kelleher N. L.; Lin H. Y.; Valaskovic G. A.; Aaserud D. J.; Fridriksson E. K.; McLafferty F. W. J. Am. Chem. Soc. 1999, 121, 806– 812.
  4. Smith R. D.; Barinaga C. J.; Udseth H. R. Anal. Chem. 1988, 60, 1948– 1952.
  5. Zubarev R. A.; Kelleher N. L.; McLafferty F. W. J. Am. Chem. Soc. 1998, 120, 3265– 3266.

Cited by

Sorted by citations

Authors
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R.
Affiliations
  • Scripps Research Institute (US)
  • Palo Alto Research Center (US)
  • The Scripps Research Institute , , 10550 North Torrey Pines Road , , ,
Corresponding author
Yates, John R.
Venue
Analytical Chemistry
Published
2014-10-26
Volume
86
Issue
22
Pages
11006-11012
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2323269825
Cited by
77
References
51
Citations by year
2026: 2 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 5 · 2020: 6 · 2019: 9 · 2018: 5 · 2017: 10 · 2016: 16 · 2015: 11
FWCI
5.28
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion, other-oa)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (8P41GM103533-17, R01 MH067880, R43 GM103352)
  • National Heart, Lung, and Blood Institute (HHSN268201000035C)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
top-down mass spectrometry, Pyrococcus furiosus, proteoforms, protein isoforms, post-translational modification, truncation, acetylation, disulfide bonds, oxidation, glycosylation, hypusine, cell lysate
MeSH terms
Electrophoresis, Capillary, Archaeal Proteins, Pyrococcus furiosus, Proteome, Proteomics, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review