The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Si:WO3 Sensors for Highly Selective Detection of Acetone for Easy Diagnosis of Diabetes by Breath Analysis
Abstract
Acetone in the human breath is an important marker for noninvasive diagnosis of diabetes. Here, novel chemo-resistive detectors have been developed that allow rapid measurement of ultralow acetone concentrations (down to 20 ppb) with high signal-to-noise ratio in ideal (dry air) and realistic (up to 90% RH) conditions. The detector films consist of (highly sensitive) pure and Si-doped WO(3) nanoparticles (10-13 nm in diameter) made in the gas phase and directly deposited onto interdigitated electrodes. Their sensing properties (selectivity, limit of detection, response, and recovery times) have been investigated as a function of operating temperature (325-500 degrees C), relative humidity (RH), and interfering analyte (ethanol or water vapor) concentration. It was found that Si-doping increases and stabilizes the acetone-selective epsilon-WO(3) phase while increasing its thermal stability and, thus, results in superior sensing performance with an optimum at about 10 mol % Si content. Furthermore, increasing the operation temperature decreased the detector response to water vapor, and above 400 degrees C, it was ( or=1800 ppb) can be clearly distinguished by a remarkable gap (40%) in sensor response. As a result, these solid state detectors may offer a portable and cost-effective alternative to more bulky systems for noninvasive diabetes detection by human breath analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helicobacter pylori Infection and the Development of Gastric Cancer
Uemura, N., Okamoto, S., Yamamoto, S., Matsumura, N., Yamaguchi, S., Yamakido, M., Taniyama, K., Sasaki, N., & Schlemper, R. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa001999 · Cited by 4,465
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Oxide Materials for Development of Integrated Gas Sensors—A Comprehensive Review
Eranna, G., Joshi, B. C., Runthala, D. P., & Gupta, R. P. (2004) · Critical Reviews in Solid State and Materials Sciences · doi:10.1080/10408430490888977 · Cited by 1,072
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Variation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
Di Natale, C., Macagnano, A., Martinelli, E., Paolesse, R., D'Arcangelo, G., Roscioni, C., Finazzi-Agrò, A., & D'Amico, A. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00086-1 · Cited by 663
Standards of Medical Care for Patients With Diabetes Mellitus
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s33 · Cited by 609
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Temperature modulation in semiconductor gas sensing
Lee, A. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00241-5 · Cited by 487
The diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
Breath Analysis: Potential for Clinical Diagnosis and Exposure Assessment
Cao, W., & Duan, Y. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063545 · Cited by 391
Inhibition of Crystallite Growth in the Sol-Gel Synthesis of Nanocrystalline Metal Oxides
Wu, N.-L., Wang, S.-Y., & Rusakova, I. A. (1999) · Science · doi:10.1126/science.285.5432.1375 · Cited by 365
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Self-citationDiskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Ferroelectric Tungsten Trioxide
Woodward, P. M., Sleight, A. W., & Vogt, T. (1997) · Journal of Solid State Chemistry · doi:10.1006/jssc.1997.7268 · Cited by 215
Lassen, A. T., Pedersen, F. M., Bytzer, P., & de Muckadell, O. B. S. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02553-8 · Cited by 208
Current Status of Methods and Techniques for Breath Analysis
Cao, W., & Duan, Y. (2007) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600976499 · Cited by 191
Electron Transfer-Induced Dynamics of Oxygen Molecules on the TiO 2 (110) Surface
Wahlström, E., Vestergaard, E. K., Schaub, R., Rønnau, A., Vestergaard, M., Lægsgaard, E., Stensgaard, I., & Besenbacher, F. (2004) · Science · doi:10.1126/science.1093425 · Cited by 189
Electrical properties of reactively sputtered WO3 thin films as ozone gas sensor
Aguir, K., Lemire, C., & Lollman, D. B. B. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00003-5 · Cited by 178
Fleischer, M., Simon, E., Rumpel, E., Ulmer, H., Harbeck, M., Wandel, M., Fietzek, C., Weimar, U., & Meixner, H. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)01056-5 · Cited by 169
Gas sensing properties of thin- and thick-film tin-oxide materials
Becker, T., Ahlers, S., Bosch-v.Braunmühl, C., Müller, G., & Kiesewetter, O. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00672-4 · Cited by 164
Lebovitz, H. E. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90645-2 · Cited by 162
Application of semiconductor gas sensors for medical diagnostics
Ryabtsev, S. V., Владимирович, Ш. А., Лукин, А. Н., & Domashevskaya, E. P. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00162-8 · Cited by 145
Pleil, J. D., & Lindstrom, A. B. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.5.723 · Cited by 120
Ferrus, L., Guénard, H. J.-P., Vardon, G., & Varène, P. (1980) · Respiration Physiology · doi:10.1016/0034-5687(80)90067-5 · Cited by 112
Measurement of Ammonia in Human Breath with a Liquid-Film Conductivity Sensor
Toda, K., Li, J., & Dasgupta, P. Κ. (2006) · Analytical Chemistry · doi:10.1021/ac060965m · Cited by 82
Metal Oxide-Based Monolithic Complementary Metal Oxide Semiconductor Gas Sensor Microsystem
Gräf, M., Barrettino, D., Taschini, S., et al. (2004) · Analytical Chemistry · doi:10.1021/ac035432h · Cited by 79
Mukhopadhyay, R. (2004) · Analytical Chemistry · doi:10.1021/ac041600+ · Cited by 58
Cited by
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Li, G., Cheng, Z., Xiang, Q., Yan, L., Wang, X., & Xu, J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.117 · Cited by 422
Shin, J., Choi, S., Lee, I., Youn, D., Park, C. O., Lee, J., Tuller, H. L., & Kim, I. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202729 · Cited by 391
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Self-citationBreath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Self-citation
Metadata
- Authors
- Righettoni, M., Tricoli, A., & Pratsinis, S. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-12
- Volume
- 82
- Issue
- 9
- Pages
- 3581-3587
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071124979
- Cited by
- 630
- References
- 30
- FWCI
- 15.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.