Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and Proteins
Abstract
Sample-matrix preparation procedures are shown to greatly influence the quality of the matrix-assisted laser desorption/ionization (MALDI) mass spectra of peptides and proteins. In particular, dramatic mass discrimination effects are observed when the matrix 4-hydroxy-alpha-cyanocinnamic acid is used for analyzing complex mixtures of peptides and proteins. The discrimination effects are found to be strongly dependent on the sample-matrix solution composition, pH, and the rates at which the sample-matrix cocrystals are grown. These findings demonstrate the need to exercise great care in performing and interpreting the MALDI analysis of biological samples. The results also indicate that there is a reverse-phase chromatographic-like dimension in the sample-matrix preparation procedures that can be exploited to optimize the analysis. The present work describes the conditions under which the majority of components of a complex mixture of peptides and proteins can be successfully measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prendergast, G. C., Lawe, D., & Ziff, E. B. (1991) · Cell · doi:10.1016/0092-8674(91)90457-a · Cited by 558
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Mühlradt, P. F., Kieß, M., Meyer, H., Süßmuth, R., & Jung, G. (1997) · The Journal of Experimental Medicine · doi:10.1084/jem.185.11.1951 · Cited by 396
Vinkemeier, U., Cohen, S. L., Moarefi, I., Chait, B. T., Kuriyan, J., & Darnell, J. E. (1996) · The EMBO Journal · doi:10.1002/j.1460-2075.1996.tb00946.x · Cited by 308
Self-citationMethods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
Prodomain processing of Asp1 (BACE2) is autocatalytic
Hussain, I., Christie, G., Schneider, K., Moore, S., & Dingwall, C. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m101069200 · Cited by 41
Metadata
- Authors
- Cohen, S. L., & Chait, B. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 1
- Pages
- 31-37
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2003593019
- Cited by
- 547
- References
- 1
- FWCI
- 18.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and Proteins. https://app.cochat.ai/papers/10.1021/ac9507956
- The paper
- Cohen, S. L., & Chait, B. T. (1996). Influence of Matrix Solution Conditions on the MALDI-MS Analysis of Peptides and Proteins. Analytical Chemistry. https://doi.org/10.1021/ac9507956
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.