The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Abstract
A microfluidic system was fabricated on a glass chip to study mobilization of biological cells on-chip. Electroosmotic and/or electrophoretic pumping were used to drive the cell transport within a network of capillary channels. Whole cells such as Saccharomyces cerevisiae, canine erythrocyte, and Escherichia coli were employed in this work. Photographs are presented to illustrate how cells are selected and transported from one location to another within the capillary network, with velocities up to about 0.5 mm/s in capillaries with a 15- x 55-microns cross section. The mixing of canine erythrocytes with the lysing agent sodium dodecyl sulfate, at an intersection within the chip, was performed to demonstrate that cell selection and subsequent reaction can be accomplished within the microchip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High efficiency transformation of E.coli by high voltage electroporation
Dower, W. J., Miller, J. F., & Ragsdale, C. W. (1988) · Nucleic Acids Research · doi:10.1093/nar/16.13.6127 · Cited by 2,809
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Self-citationCapillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Self-citationDielectric Breakdown of Cell Membranes
Zimmermann, U., Pilwat, G., & Riemann, F. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85956-4 · Cited by 762
Electrical Breakdown of Bimolecular Lipid Membranes as an Electromechanical Instability
Crowley, J. M. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86017-5 · Cited by 392
High-Density Nanosecond Charge Trapping in Thin Films of the Photoconductor ZnODEP
Liu, C.-Y., Pan, H.-L., Fox, M. A., & Bard, A. J. (1993) · Science · doi:10.1126/science.261.5123.897 · Cited by 274
Blood: A Textbook of Hematology.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-504_5 · Cited by 195
Electrochemical detection in microcolumn separations
Ewing, A. G., Mesaros, J. M., & Gavin, P. F. (1994) · Analytical Chemistry · doi:10.1021/ac00081a002 · Cited by 167
Research works printed but not linked: 25
- Fan Z. H., 1994, J. Anal. Chem., 66, 184
- Seiler K., 1994, J. Anal. Chem., 66, 3491, 10.1021/ac00092a029 · doi:10.1021/ac00092a029
- (b) Harrison, D. J.; Fluri, K.; Chiem, N.; Tang, T.; Fan, Z.Technical Digest, Transducers 95, 8th International Conference on Solid-State Sensors and Actuators, Stockholm, June 25−29, 1995; pp 752−755.
- Effenhauser C. S., 1993, Anal. Chem., 65, 2642, 10.1021/ac00067a015 · doi:10.1021/ac00067a015
- Jacobson S. C., 1994, Anal. Chem., 66, 2373
- Jacobson S. C., 1994, Anal. Chem., 66, 3476
- Raymond, D. E.; Manz, A.; Widmer, H. M.Technical Digest, Transducers 95, 8th International Conference on Solid-State Sensors and Actuators, Stockholm, June 25−29, 1995; p 760.
- Washizu, 1990, Integrated Micro-motion systemsMicromachining, Control and Applications, 431
- Tracey M. C., 1995, J. IEEE Trans. Biomed. Eng., 42, 761
- Kricka L. J., 1993, Clin. Chem., 39, 1947, 10.1093/clinchem/39.9.1944 · doi:10.1093/clinchem/39.9.1944
- Wilding P., 1994, J. Clin. Chem., 40, 47
- Zhu A., 1989, J. Chromatogr. A, 470, 260
- Lillard S. J., 1995, J. Chromatogr. A, 718, 404, 10.1016/0021-9673(95)00702-4 · doi:10.1016/0021-9673(95)00702-4
- Xue Q., 1994, Anal. Chem., 66, 1178
- Kitagawa S., 1995, Electrophoresis, 16, 1368, 10.1002/elps.11501601225 · doi:10.1002/elps.11501601225
- Wallenford R. A., 1988, Anal. Chem., 60, 1979, 10.1021/ac00169a030 · doi:10.1021/ac00169a030
- Slappendel R. J., 1994, J. Blood, 84, 909, 10.1182/blood.V84.3.904.904 · doi:10.1182/blood.v84.3.904.904
- Agar N. S., 1983, Board
- Greenwalt T. J., 1973, The human red cell in vivo
- Seiler K., 1993, Anal. Chem., 65, 1488, 10.1021/ac00058a029 · doi:10.1021/ac00058a029
- Lehninger A. L., 1975, Biochemistry
- Berry D. R., 1982, The Biology of Yeast
- Rech E. L., 1990, J. Nucleic Acids Res., 18, 1313, 10.1093/nar/18.5.1313 · doi:10.1093/nar/18.5.1313
- Serpersu E. H., 1985, Biochim. Biophys. Acta, 812, 779, 10.1016/0005-2736(85)90272-X · doi:10.1016/0005-2736(85)90272-x
- Jandl J. H., 1987, BloodTextbook of Hematology
Cited by
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Microfluidic Device for Single-Cell Analysis
Wheeler, A. R., Throndset, W. R., Whelan, R. J., Leach, A. M., Zare, R. N., Liao, Y. H., Farrell, K., Manger, I. D., & Daridon, A. (2003) · Analytical Chemistry · doi:10.1021/ac0340758 · Cited by 600
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Microenvironment design considerations for cellular scale studies
Walker, G. M., Zeringue, H. C., & Beebe, D. J. (2004) · Lab on a Chip · doi:10.1039/b311214d · Cited by 388
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Gao, J., Yin, X.-F., & Fang, Z.-L. (2004) · Lab on a Chip · doi:10.1039/b310552k · Cited by 300
The Tumor Microenvironment: A Pitch for Multiple Players
Schiavoni, G., Gabriele, L., & Mattei, F. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00090 · Cited by 147
Metadata
- Authors
- Li, P. C. H., & Harrison, D. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-04-01
- Volume
- 69
- Issue
- 8
- Pages
- 1564-1568
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2075116234
- Cited by
- 422
- References
- 8
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.