Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects

Li, Paul C. H., Harrison, D. Jed·1997·Analytical Chemistry

Abstract

A microfluidic system was fabricated on a glass chip to study mobilization of biological cells on-chip. Electroosmotic and/or electrophoretic pumping were used to drive the cell transport within a network of capillary channels. Whole cells such as Saccharomyces cerevisiae, canine erythrocyte, and Escherichia coli were employed in this work. Photographs are presented to illustrate how cells are selected and transported from one location to another within the capillary network, with velocities up to about 0.5 mm/s in capillaries with a 15- x 55-microns cross section. The mixing of canine erythrocytes with the lysing agent sodium dodecyl sulfate, at an intersection within the chip, was performed to demonstrate that cell selection and subsequent reaction can be accomplished within the microchip.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9606564

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 25

  1. Fan Z. H., 1994, J. Anal. Chem., 66, 184
  2. Seiler K., 1994, J. Anal. Chem., 66, 3491, 10.1021/ac00092a029 · doi:10.1021/ac00092a029
  3. (b) Harrison, D. J.; Fluri, K.; Chiem, N.; Tang, T.; Fan, Z.Technical Digest, Transducers 95, 8th International Conference on Solid-State Sensors and Actuators, Stockholm, June 25−29, 1995; pp 752−755.
  4. Effenhauser C. S., 1993, Anal. Chem., 65, 2642, 10.1021/ac00067a015 · doi:10.1021/ac00067a015
  5. Jacobson S. C., 1994, Anal. Chem., 66, 2373
  6. Jacobson S. C., 1994, Anal. Chem., 66, 3476
  7. Raymond, D. E.; Manz, A.; Widmer, H. M.Technical Digest, Transducers 95, 8th International Conference on Solid-State Sensors and Actuators, Stockholm, June 25−29, 1995; p 760.
  8. Washizu, 1990, Integrated Micro-motion systemsMicromachining, Control and Applications, 431
  9. Tracey M. C., 1995, J. IEEE Trans. Biomed. Eng., 42, 761
  10. Kricka L. J., 1993, Clin. Chem., 39, 1947, 10.1093/clinchem/39.9.1944 · doi:10.1093/clinchem/39.9.1944
  11. Wilding P., 1994, J. Clin. Chem., 40, 47
  12. Zhu A., 1989, J. Chromatogr. A, 470, 260
  13. Lillard S. J., 1995, J. Chromatogr. A, 718, 404, 10.1016/0021-9673(95)00702-4 · doi:10.1016/0021-9673(95)00702-4
  14. Xue Q., 1994, Anal. Chem., 66, 1178
  15. Kitagawa S., 1995, Electrophoresis, 16, 1368, 10.1002/elps.11501601225 · doi:10.1002/elps.11501601225
  16. Wallenford R. A., 1988, Anal. Chem., 60, 1979, 10.1021/ac00169a030 · doi:10.1021/ac00169a030
  17. Slappendel R. J., 1994, J. Blood, 84, 909, 10.1182/blood.V84.3.904.904 · doi:10.1182/blood.v84.3.904.904
  18. Agar N. S., 1983, Board
  19. Greenwalt T. J., 1973, The human red cell in vivo
  20. Seiler K., 1993, Anal. Chem., 65, 1488, 10.1021/ac00058a029 · doi:10.1021/ac00058a029
  21. Lehninger A. L., 1975, Biochemistry
  22. Berry D. R., 1982, The Biology of Yeast
  23. Rech E. L., 1990, J. Nucleic Acids Res., 18, 1313, 10.1093/nar/18.5.1313 · doi:10.1093/nar/18.5.1313
  24. Serpersu E. H., 1985, Biochim. Biophys. Acta, 812, 779, 10.1016/0005-2736(85)90272-X · doi:10.1016/0005-2736(85)90272-x
  25. Jandl J. H., 1987, BloodTextbook of Hematology

Cited by

Metadata

Authors
Li, P. C. H., & Harrison, D. J.
Venue
Analytical Chemistry
Published
1997-04-01
Volume
69
Issue
8
Pages
1564-1568
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2075116234
Cited by
422
References
8
FWCI
17.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.