Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 397

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Microchip-Based Capillary Electrophoresis for Immunoassays: Analysis of Monoclonal Antibodies and Theophylline

Chiem, Nghia, Harrison, D. Jed·1997·Analytical Chemistry

Abstract

A microchip capillary electrophoresis device has been used to separate the reaction products of homogeneous, immunological reactions within approximately 40 s. Determination of monoclonal mouse IgG in mouse ascites fluid, via a direct assay, and the drug theophylline in serum samples, via a competitive assay, was demonstrated on-chip. The mouse anti-bovine serum albumin IgG assay gave a linear calibration curve up to at least 135 micrograms/mL, with +/- 3% precision. The theophylline assay gave a threshold for detection of 1.25 ng/mL in diluted serum. A calibration curve of signal vs undiluted log[theophylline] is linear from 2.5 to 40 micrograms/mL, which includes the therapeutically useful range. Theophylline recoveries in spiked samples were 100%, within an experimental error of +/- 5%. A buffer system consisting of 0.05 M tricine adjusted to pH 8.0, 0.01% (w/v) Tween 20, and approximately 40 mM NaCl was used. This buffer allowed for adequate separation (40,000 plates for theophylline; 1000 plates for theophylline-antibody complex and for human IgG) and gave reproducibility of migration times of 1-1.5% over 4-day periods, indicating minimal problems from adsorption in the uncoated chips.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9606620

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 397

Metadata

Authors
Chiem, N., & Harrison, D. J.
Venue
Analytical Chemistry
Published
1997-02-01
Volume
69
Issue
3
Pages
373-378
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2047725750
Cited by
397
References
6
FWCI
40.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.