Microchip-Based Capillary Electrophoresis for Immunoassays: Analysis of Monoclonal Antibodies and Theophylline
Abstract
A microchip capillary electrophoresis device has been used to separate the reaction products of homogeneous, immunological reactions within approximately 40 s. Determination of monoclonal mouse IgG in mouse ascites fluid, via a direct assay, and the drug theophylline in serum samples, via a competitive assay, was demonstrated on-chip. The mouse anti-bovine serum albumin IgG assay gave a linear calibration curve up to at least 135 micrograms/mL, with +/- 3% precision. The theophylline assay gave a threshold for detection of 1.25 ng/mL in diluted serum. A calibration curve of signal vs undiluted log[theophylline] is linear from 2.5 to 40 micrograms/mL, which includes the therapeutically useful range. Theophylline recoveries in spiked samples were 100%, within an experimental error of +/- 5%. A buffer system consisting of 0.05 M tricine adjusted to pH 8.0, 0.01% (w/v) Tween 20, and approximately 40 mM NaCl was used. This buffer allowed for adequate separation (40,000 plates for theophylline; 1000 plates for theophylline-antibody complex and for human IgG) and gave reproducibility of migration times of 1-1.5% over 4-day periods, indicating minimal problems from adsorption in the uncoated chips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibodies, a laboratory manual
(1989) · Biomedicine & Pharmacotherapy · doi:10.1016/0753-3322(89)90130-3 · Cited by 12,366
Hydrogen Ion Buffers for Biological Research*
Good, N. E., Winget, G. D., Winter, W., Connolly, T. N., Izawa, S., & Singh, R. M. M. (1966) · Biochemistry · doi:10.1021/bi00866a011 · Cited by 2,762
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Self-citationCapillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Self-citationMicrochip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315
Capillary Electrophoresis-Based Immunoassay for Cortisol in Serum
Schmalzing, D., Nashabeh, W., Yao, X.-W., Mhatre, R., Regnier, F. E., Afeyan, N. B., & Fuchs, M. (1995) · Analytical Chemistry · doi:10.1021/ac00099a019 · Cited by 104
Cited by
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Yu, C., Davey, M. H., Svec, F., & Fréchet, J. M. J. (2001) · Analytical Chemistry · doi:10.1021/ac0106288 · Cited by 354
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Metadata
- Authors
- Chiem, N., & Harrison, D. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-02-01
- Volume
- 69
- Issue
- 3
- Pages
- 373-378
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2047725750
- Cited by
- 397
- References
- 6
- FWCI
- 40.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.