CoChat

Determination of Glucose in Submicroliter Samples by CE−LIF Using Precolumn or On-Column Enzymatic Reactions

Jin, Zhe, Chen, Rong, Colón, Luis A. · 1997 · Analytical Chemistry
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Two enzymatic reactions combined with capillary electrophoresis (CE) are used to determine glucose contained in sample volumes of ≤500 nL. In the first enzymatic reaction, glucose is oxidized in the presence of glucose oxidase producing hydrogen peroxide, which reacts quantitatively with the fluorogenic compound homovanillic acid catalyzed by the enzyme peroxidase. The second reaction generates a fluorescent species that is proportional to the glucose concentration. The reaction product is determined by CE using laser-induced fluorescence (LIF) as the detection mode. The overall reaction scheme is faster than commonly used precolumn derivatization procedures and can be performed using very small sample quantities. Alternatively, the enzymatic reactions can be performed on-column, similar to the electrophoretically mediated microanalysis approach, accommodating sample quantities in the nanoliter range. The on-column reaction is a simple and practical approach for the determination of glucose contained in low-volume samples by CE-LIF, where samples are injected directly into the capillary column without any pretreatment. However, sample handling and detectability of the precolumn approach proved to be superior. Determination of glucose using the precolumn and on-column reactions showed detection limits of 50 and 800 nM, respectively. The methods were shown to be linear in the range tested, 1-100 μM and 100 nM-30 μM, for the on-column and precolumn reactions, respectively. The reproducibility for each scheme was <5% RSD. To determine the possibility of using a noninvasive procedure for glucose monitoring, we used the CE-LIF methods to analyze human tear samples for glucose. The tear fluid samples were contained in a volume of ∼200 nL. The concentration of glucose in the human tear samples analyzed using the precolumn and on-column procedures was ∼138 μM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac960724m

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 64

Metadata

Authors
Jin, Z., Chen, R., & Colón, L. A.
Venue
Analytical Chemistry
Published
1997-04-01
Volume
69
Issue
7
Pages
1326-1331
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2094271997
Cited by
64
References
1
FWCI
5.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.