Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Hydrogen ion selective microelectrode prepared by modifying an electrode with polymers
Oyama, N., Hirokawa, T., Yamaguchi, S., Ushizawa, N., & Shimomura, T. (1987) · Analytical Chemistry · doi:10.1021/ac00129a009 · Cited by 120
Mechanism of ionic and redox sensitivity of p-type conducting polymers
Bobacka, J., Gao, Z., Ivaska, A. U., & Lewenstam, A. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03081-y · Cited by 114
Self-citationSome alkylphosphoric acid esters for use in coated-wire calcium-selective electrodes
Cattrall, R. W., Drew, D. M., & Hamilton, I. C. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)85398-8 · Cited by 108
Mechanism of ionic and redox sensitivity of p-type conducting polymers
Lewenstam, A., Bobacka, J., & Ivaska, A. U. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03080-9 · Cited by 104
Self-citationAll solid-state hydrogen ion-selective electrode based on a conducting poly(pyrrole) solid contact
Michalska, A., Hulanicki, A., & Lewenstam, A. (1994) · The Analyst · doi:10.1039/an9941902417 · Cited by 101
Novel polypyrrole based all-solid-state potassium-selective microelectrodes
Gyurcsányi, R. E., Nybäck, A.-S., Ivaska, A. U., Tóth, K., & Nagy, G. (1998) · The Analyst · doi:10.1039/a800389k · Cited by 99
Hauser, P. C., Chiang, D. W. L., & Wright, G. A. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00472-x · Cited by 99
Bobacka, J., Ivaska, A. U., & Lewenstam, A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00667-9 · Cited by 95
Self-citationCalcium-selective electrodes with pvc membranes and solid internal contacts
Hulanicki, A., & Trojanowicz, M. (1976) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82269-8 · Cited by 86
Potassium ion responsive coated wire electrode based on valinomycin
Cattrall, R. W., Tribuzio, S., & Freiser, H. (1974) · Analytical Chemistry · doi:10.1021/ac60350a026 · Cited by 83
Anionic responses of electrochemically synthesized polypyrrole films
Cadogan, A. (1992) · Talanta · doi:10.1016/0039-9140(92)80070-t · Cited by 64
All‐solid‐state chloride‐selective electrode with poly(pyrrole) solid contact
Hulanicki, A., & Michalska, A. (1995) · Electroanalysis · doi:10.1002/elan.1140070718 · Cited by 53
Bobacka, J., Lewenstam, A., & Ivaska, A. U. (1993) · Talanta · doi:10.1016/0039-9140(93)80223-e · Cited by 43
Self-citationDefining a Recombination Efficiency for Sealed, Lead‐Acid Batteries: A Material Balance Approach
Symanski, J. S., Mahato, B., & Bullock, K. R. (1988) · Journal of The Electrochemical Society · doi:10.1149/1.2095655 · Cited by 37
Bobacka, J., Grzeszczuk, M., & Ivaska, A. U. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)05023-1 · Cited by 36
Self-citationLindfors, T., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (1996) · The Analyst · doi:10.1039/an9962101823 · Cited by 36
Self-citationKomaba, S., Arakawa, J., Seyama, M., Ōsaka, T., Satoh, I., & NAKAMURA, S. (1998) · Talanta · doi:10.1016/s0039-9140(97)00396-2 · Cited by 34
Characterization of biosensors based on membranes containing a conducting polymer
Battilotti, M., Colapicchioni, C., Giannini, I., Porcelli, F., Campanella, L., Cordatore, M., Mazzei, F., & TOMASSETTI, M. (1989) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)81949-2 · Cited by 31
On the nature of the potentiometric response of polypyrrole in acidic solutions
Michalska, A., Maksymiuk, K., & Hulanicki, A. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)03996-t · Cited by 30
Momma, T., Yamamoto, M., Komaba, S., & Ōsaka, T. (1996) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04459-0 · Cited by 27
Gunasingham, H., Tay, B. T., & Ang, K. P. (1987) · Analytical Chemistry · doi:10.1021/ac00129a010 · Cited by 19
Ion-Selective Electrodes Based on Bilayer Film Coating
Oyama, N., Ohsaka, T., Yoshimura, F., Mizunuma, M., Yamaguchi, S., Ushizawa, N., & Shimomura, T. (1988) · Journal of Macromolecular Science Part A - Chemistry · doi:10.1080/00222338808053434 · Cited by 17
Separation of fluoride and chloride by solvent extraction using triphenylantimony(V) derivatives
Chermette, H., Martelet, C., SANDINO, D., & Tousset, J. (1972) · Analytical Chemistry · doi:10.1021/ac60312a008 · Cited by 16
Kriksunov, L. B., & Macdonald, D. D. (1998) · Journal of The Electrochemical Society · doi:10.1149/1.1838922 · Cited by 6
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
“The common reference electrode for the Na + and K + ISEs was modified by casting 10 µ l of reference solution onto the Ag/AgCl electrode.”
BackgroundMethodInfluentialBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
Self-citationRational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
“Also, reference membranes loaded with ionic liquids were applied in all-solid-state reference electrodes with PEDOT [76], 3DOM carbon [77], CIM carbon [78], and lipophilic Co(II)/Co(III) salts [79] to form the solid contact.”
BackgroundMethodInfluentialShao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.