CoChat

Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers

Bobacka, Johan · 1999 · Analytical Chemistry

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac990497z

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Research works printed but not linked: 7

  1. Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
  2. Buck R. P., 1976, Anal. Chem., 48, 39R
  3. Momma T., 1995, Sens. Acuators, B, 24, 728
  4. Pandey P. C., 1998, Sens. Actuators, B, 46, 65
  5. Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
  6. Bobacka J., 1991, Synth. Met., 44, 34
  7. Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.

Cited by

See all 686

Metadata

Authors
Bobacka, J.
Affiliations
Åbo Akademi University (FI)
Corresponding author
Bobacka, Johan
Venue
Analytical Chemistry
Published
1999-10-01
Volume
71
Issue
21
Pages
4932-4937
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2000694408
Cited by
686
References
34
Citations by year
2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
FWCI
4.77
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Åbo Akademi University Research Portal (submittedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.