Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Demanding analytical applications such as on-line process analysis and clinical analysis require robust, reliable, and maintenance-free ion sensors of high potential stability. In this work the stability of the electrode potential of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers is critically evaluated by using chronopotentiometry and electrochemical impedance spectroscopy. This study is focused on the relationship between the potential stability of the electrode and the capacitance of the solid contact where ion-to-electron transduction takes place. The influence of this capacitance on the potential stability of all-solid-state ion-selective electrodes is studied experimentally by using conducting polymer layers of different thickness as solid contacts in potassium ion-selective electrodes based on a solvent polymeric membrane. Because of its excellent environmental stability, the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) is used as a model compound for the solid contact material. Chronopotentiometry is found to be a convenient and fast experimental method to critically evaluate the potential stability of different types of ion-selective electrodes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also, the high impedance nature of the ISE-based sensors37 required the use of high-impedance voltage buffers to ensure accurate open voltage measurement as intended.”
From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [37]
Citations
Cites
Handbook of conducting polymers
Skotheim, T. A., Elsenbaumer, R. L., & Reynolds, J. R. (1986) · M. Dekker eBooks · Cited by 8,079
Poly(alkylenedioxythiophene)s—new, very stable conducting polymers
Heywang, G., & Jonas, F. (1992) · Advanced Materials · doi:10.1002/adma.19920040213 · Cited by 1,027
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Horvai, G., Graf, E., Toth, K., Pungor, E., & Buck, R. P. (1986) · Analytical Chemistry · doi:10.1021/ac00126a034 · Cited by 235
GUSTAFSSON, J., LIEDBERG, B., & INGANAS, O. (1994) · Solid State Ionics · doi:10.1016/0167-2738(94)90403-0 · Cited by 213
Technical applications for conductive polymers
Jonas, F., & Heywang, G. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)e0057-7 · Cited by 202
Single-piece all-solid-state ion-selective electrode
Bobacka, J., Lindfors, T., McCarrick, M., Ivaska, A., & Lewenstam, A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a034 · Cited by 188
Self-citationBobacka, J., McCarrick, M., Lewenstam, A., & Ivaska, A. (1994) · The Analyst · doi:10.1039/an9941901985 · Cited by 175
Self-citationCharacterization of electroactive polymer layers by electrochemical impedance spectroscopy (EIS)
Musiani, M. M. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80023-h · Cited by 148
Research works printed but not linked: 7
- Nikolskii B. P., 1985, Ion-Sel. Electrode Rev., 7, 39
- Buck R. P., 1976, Anal. Chem., 48, 39R
- Momma T., 1995, Sens. Acuators, B, 24, 728
- Pandey P. C., 1998, Sens. Actuators, B, 46, 65
- Glarum S. H., 1987, J. Electrochem. Soc., 134, 147
- Bobacka J., 1991, Synth. Met., 44, 34
- Koryta, J.; Dvorak, J.; Kavan, L. Principles of Electrochemistry , 2nd ed.; Wiley: Chichester, U.K., 1993; p 38.
Cited by
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
“The common reference electrode for the Na + and K + ISEs was modified by casting 10 µ l of reference solution onto the Ag/AgCl electrode.”
BackgroundMethodInfluentialBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Bobacka, J., Ivaska, A., & Lewenstam, A. (2008) · Chemical Reviews · doi:10.1021/cr068100w · Cited by 975
Self-citationRational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
“Also, reference membranes loaded with ionic liquids were applied in all-solid-state reference electrodes with PEDOT [76], 3DOM carbon [77], CIM carbon [78], and lipophilic Co(II)/Co(III) salts [79] to form the solid contact.”
BackgroundMethodInfluentialShao, Y., Ying, Y., & Ping, J. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00587k · Cited by 472
Fibbioli, M., Morf, W. E., Badertscher, M., de Rooij, N. F., & Pretsch, E. (2000) · Electroanalysis · doi:10.1002/1521-4109(200011)12:16<1286::aid-elan1286>3.0.co;2-q · Cited by 443
Ion-Selective Electrodes Using Carbon Nanotubes as Ion-to-Electron Transducers
Crespo, G. A., Macho, S., & Rius, F. X. (2008) · Analytical Chemistry · doi:10.1021/ac071156l · Cited by 425
Bobacka, J., Lewenstam, A., & Ivaska, A. (2000) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(00)00206-0 · Cited by 425
Self-citationConducting Polymer‐Based Solid‐State Ion‐Selective Electrodes
Bobacka, J. (2006) · Electroanalysis · doi:10.1002/elan.200503384 · Cited by 418
Self-citationWearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Flexible Electrochemical Bioelectronics: The Rise of In Situ Bioanalysis
Yu, Y., Nyein, H. Y. Y., Gao, W., & Javey, A. (2020) · Advanced Materials · doi:10.1002/adma.201902083 · Cited by 349
Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes
Lindner, E., & Gyurcsányi, R. E. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0608-1 · Cited by 320
Tattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Electrochemical bandgaps of substituted polythiophenes
Johansson, T., Mammo, W., Svensson, M., Andersson, M. R., & Inganäs, O. (2003) · J. Mater. Chem. · doi:10.1039/b301403g · Cited by 313
Ion-Selective Electrodes with Three-Dimensionally Ordered Macroporous Carbon as the Solid Contact
Lai, C.-Z., Fierke, M. A., Stein, A., & Bühlmann, P. (2007) · Analytical Chemistry · doi:10.1021/ac070132b · Cited by 286
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 277
Self-citationImpedance spectroscopy: Over 35 years of electrochemical sensor optimization
Pejcic, B., & De Marco, R. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.04.025 · Cited by 270
Transduction Mechanism of Carbon Nanotubes in Solid-Contact Ion-Selective Electrodes
Crespo, G. A., Macho, S., Bobacka, J., & Rius, F. X. (2009) · Analytical Chemistry · doi:10.1021/ac802078z · Cited by 248
Self-citationStavrinidou, E., Gabrielsson, R., Gomez, E., Crispin, X., Nilsson, O., Simon, D. T., & Berggren, M. (2015) · Science Advances · doi:10.1126/sciadv.1501136 · Cited by 240
“This “electrochemical” activity has been extensively utilized as the principle of operation in various organic electrochemical transistors (OECTs) (12), sensors (13), electrodes (14), supercapacitors (15), energy conversion devices (16), and electrochromic display (OECD) cells (9, 17).”
BackgroundIon-Selective Electrodes with Colloid-Imprinted Mesoporous Carbon as Solid Contact
Hu, J., Zou, X. U., Stein, A., & Bühlmann, P. (2014) · Analytical Chemistry · doi:10.1021/ac501633r · Cited by 209
Ates, M. (2011) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2010.12.011 · Cited by 208
Applications of nanomaterials in potentiometric sensors
Yin, T., & Qin, W. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.009 · Cited by 206
“However, one limitation of SAM is its inherently low redox capacitance, which is unfavorable for solid-contact ISEs [4].”
BackgroundApplication of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode
Ping, J., Wang, Y., Ying, Y., & Wu, J. (2012) · Analytical Chemistry · doi:10.1021/ac203480z · Cited by 199
All‐Solid‐State Ion Selective and All‐Solid‐State Reference Electrodes
Michalska, A. (2012) · Electroanalysis · doi:10.1002/elan.201200059 · Cited by 186
Elimination of Undesirable Water Layers in Solid-Contact Polymeric Ion-Selective Electrodes
Veder, J.-P., De Marco, R., Clarke, G., Chester, R., Nelson, A., Prince, K., Pretsch, E., & Bakker, E. (2008) · Analytical Chemistry · doi:10.1021/ac800823f · Cited by 181
Tamburri, E., Orlanducci, S., Toschi, F., Terranova, M. L., & Passeri, D. (2009) · Synthetic Metals · doi:10.1016/j.synthmet.2008.10.014 · Cited by 177
Ping, J., Wang, Y., Wu, J., & Ying, Y. (2011) · Electrochemistry Communications · doi:10.1016/j.elecom.2011.10.018 · Cited by 177
All-solid-state potassium-selective electrode using graphene as the solid contact
Li, F., Ye, J., Zhou, M., Gan, S., Zhang, Q., Han, D., & Niu, L. (2012) · The Analyst · doi:10.1039/c1an15705a · Cited by 178
Calibration-free potentiometric sensing with solid-contact ion-selective electrodes
Rousseau, C. R., & Bühlmann, P. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116277 · Cited by 172
Faridbod, F., Norouzi, P., Dinarvand, R., & Ganjali, M. R. (2008) · Sensors · doi:10.3390/s8042331 · Cited by 163
“charging/discharging of the bulk capacitance [17].”
Evidence of a water layer in solid-contact polymeric ion sensors
MARCO, R. D., Veder, J., Clarke, G., Nelson, A. R. J., Prince, K. E., Pretsch, E., & Bakker, E. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b714248j · Cited by 158
Lyu, Y., Gan, S., Bao, Y., Zhong, L., Xu, J., Wang, W., Liu, Z., Ma, Y., Yang, G., & Niu, L. (2020) · Membranes · doi:10.3390/membranes10060128 · Cited by 167
Vázquez, M., Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00983-2 · Cited by 148
Self-citationWearable Potentiometric Sensors for Medical Applications
Cuartero, M., Parrilla, M., & Crespo, G. A. (2019) · Sensors · doi:10.3390/s19020363 · Cited by 153
“while maintaining the same analytical features, the all-solid-state concept offers a series of unique advantages [1,5,6]: (i) The size of ISEs is scaled down to the nano-level [2]; (ii) Easy implementation in fluidic systems, which fosters in-line incorporation of special pre-treatments [7,8]; (iii) Requirement of ver…”
BackgroundLi, C., & Imae, T. (2004) · Macromolecules · doi:10.1021/ma035188w · Cited by 140
All-solid-state potentiometric sensors: A new wave for in situ aquatic research
Cuartero, M., & Crespo, G. A. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.04.004 · Cited by 144
Conductive Metal–Organic Frameworks as Ion-to-Electron Transducers in Potentiometric Sensors
Mendecki, L., & Mirica, K. A. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b03956 · Cited by 134
An, Q., Gan, S., Xu, J., Bao, Y., Wu, T., Kong, H., Zhong, L., Ma, Y., Song, Z., & Niu, L. (2019) · Electrochemistry Communications · doi:10.1016/j.elecom.2019.106553 · Cited by 133
Ali, M. A., Wang, X., Chen, Y., Jiao, Y., Mahal, N. K., Satyanarayana, M., Castellano, M. J., Schnable, J. C., Schnable, P. S., & Dong, L. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07120 · Cited by 131
Sutter, J., Lindner, E., Gyurcsányi, R. E., & Pretsch, E. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2737-4 · Cited by 127
Vázquez, M., Danielsson, P., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.08.010 · Cited by 125
“disk electrode and subsequently coated by a plasticized PVC-based ion-selective membrane by solution casting [9,13–16].”
BackgroundMethodSelf-citationMousavi, Z., Bobacka, J., Lewenstam, A., & Ivaska, A. U. (2009) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2009.06.005 · Cited by 123
Self-citationBao, B., Hao, J., Bian, X., Zhu, X., Xiao, K., Liao, J., Zhou, J., Zhou, Y., & Jiang, L. (2017) · Advanced Materials · doi:10.1002/adma.201702926 · Cited by 120
Yun, H., Bian, C., Xia, S., Tong, J., & Wang, J. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.080 · Cited by 123
Vonau, W., & Guth, U. (2006) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-006-0120-4 · Cited by 119
Hernández, R., Riu, J., Bobacka, J., Vallés, C., Jiménez, P., Benito, A. M., Maser, W. K., & Rius, F. X. (2012) · The Journal of Physical Chemistry C · doi:10.1021/jp306234u · Cited by 118
Self-citationApproaches to Improving the Lower Detection Limit of Polymeric Membrane Ion‐Selective Electrodes
Szigeti, Z., Vigassy, T., Bakker, E., & Pretsch, E. (2006) · Electroanalysis · doi:10.1002/elan.200603539 · Cited by 118
Gyurcsányi, R. E. (2004) · Talanta · doi:10.1016/j.talanta.2003.12.002 · Cited by 118
Chauhan, N. P. S., Mozafari, M., Chundawat, N. S., Meghwal, K., Ameta, R., & Ameta, S. C. (2016) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2016.03.003 · Cited by 117
Redox-Active Self-Assembled Monolayers for Solid-Contact Polymeric Membrane Ion-Selective Electrodes
Fibbioli, M., Bandyopadhyay, K., Liu, S., Echegoyen, L. A., Enger, O., Diederich, F., Gingery, D., Bühlmann, P., Persson, H. H. J., Suter, U. W., et al. (2002) · Chemistry of Materials · doi:10.1021/cm0109589 · Cited by 114
Fierke, M. A., Lai, C., Bühlmann, P., & Stein, A. (2009) · Analytical Chemistry · doi:10.1021/ac902222n · Cited by 115
New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes
Mattinen, U., Hupa, E., Yrjänä, V., & Bobacka, J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04800 · Cited by 112
Self-citationElectropolymerisation of 3,4-ethylenedioxythiophene in aqueous solutions
Pigani, L., Heras, A., Colina, Á., Seeber, R., & López‐Palacios, J. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.09.021 · Cited by 108
Rius-Ruiz, F. X., Crespo, G. A., Bejarano-Nosas, D., Blondeau, P., Riu, J., & Rius, F. X. (2011) · Analytical Chemistry · doi:10.1021/ac202070r · Cited by 108
Solid Contact Ion-Selective Electrodes with a Well-Controlled Co(II)/Co(III) Redox Buffer Layer
Zou, X. U., Cheong, J. H., Taitt, B. J., & Bühlmann, P. (2013) · Analytical Chemistry · doi:10.1021/ac4022117 · Cited by 107
Michalska, A., Dumańska, J., & Maksymiuk, K. (2003) · Analytical Chemistry · doi:10.1021/ac034335l · Cited by 105
Electrochemical polymerization and properties of PEDOT/S-EDOT on neural microelectrode arrays
Xiao, Y., Cui, X. T., & Martin, D. C. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2004.06.024 · Cited by 112
Lindfors, T., & Ivaska, A. U. (2004) · Analytical Chemistry · doi:10.1021/ac049439q · Cited by 103
Han, T., Mattinen, U., & Bobacka, J. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01649 · Cited by 102
Self-citationSundfors, F., Bobacka, J., Ivaska, A. U., & Lewenstam, A. (2002) · Electrochimica Acta · doi:10.1016/s0013-4686(02)00063-4 · Cited by 102
Self-citationThin Layer Ionophore-Based Membrane for Multianalyte Ion Activity Detection
Crespo, G. A., Cuartero, M., & Bakker, E. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01459 · Cited by 102
Michalska, A. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0132-4 · Cited by 101
All-solid-state selective electrodes using carbon black
Paczosa‐Bator, B. (2012) · Talanta · doi:10.1016/j.talanta.2012.02.013 · Cited by 102
Baba, A., Lübben, J. F., Tamada, K., & Knoll, W. (2003) · Langmuir · doi:10.1021/la034848n · Cited by 100
Lindfors, T. (2008) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0561-z · Cited by 99
Novel Ion‐to‐Electron Transduction Principle for Solid‐Contact ISEs
Hupa, E., Mattinen, U., & Bobacka, J. (2015) · Electroanalysis · doi:10.1002/elan.201400596 · Cited by 97
Self-citationMichalska, A., Appaih-Kusi, C., Heng, L. Y., Walkiewicz, S., & Hall, E. A. H. (2004) · Analytical Chemistry · doi:10.1021/ac0353132 · Cited by 97
He, N., Papp, S., Lindfors, T., Höfler, L., Latonen, R., & Gyurcsányi, R. E. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04885 · Cited by 96
All-solid-state planar miniature ion-selective chloride electrode
Zielińska, R., Mulik, E., Michalska, A., Achmatowicz, S., & Maj‐Żurawska, M. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01407-6 · Cited by 95
Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings
Jaworska, E., Wójcik, M., Kisiel, A., Mieczkowski, J. B., & Michalska, A. (2011) · Talanta · doi:10.1016/j.talanta.2011.07.049 · Cited by 93
Development of miniature all-solid-state potentiometric sensing system
Anastasova, S., Mattinen, U., Radu, A., Bobacka, J., Lewenstam, A., Migdalski, J., Danielewski, M., & Diamond, D. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.02.044 · Cited by 92
“…Eco Chemie, B.V., and the Netherlands) with galvanostatic electropolymerization, by applying a current of 0.00157 mA onto 0.00785 cm 2 for 714 s. Due to the low solubility of the EDOT monomer in water (0.01 M), PEDOT was electrodeposited at a low current density (0.2 mA cm -2 ) [24].”
InfluentialSelf-citationNanomolar Detection Limits of Cd2+, Ag+, and K+ Using Paper-Strip Ion-Selective Electrodes
Mensah, S. T., Gonzalez, Y., Calvo‐Marzal, P., & Chumbimuni‐Torres, K. Y. (2014) · Analytical Chemistry · doi:10.1021/ac501470p · Cited by 93
All-plastic, disposable, low detection limit ion-selective electrodes
Michalska, A., & Maksymiuk, K. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.07.020 · Cited by 91
Solid contact potassium selective electrodes for biomedical applications – a review
van de Velde, L., d’Angremont, E., & Olthuis, W. (2016) · Talanta · doi:10.1016/j.talanta.2016.06.050 · Cited by 90
Zou, X. U., Zhen, X. V., Cheong, J. H., & Bühlmann, P. (2014) · Analytical Chemistry · doi:10.1021/ac501625z · Cited by 90
Criscuolo, F., Taurino, I., Stradolini, F., Carrara, S., & Micheli, G. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.062 · Cited by 89
Guziński, M., Jarvis, J. M., Perez, F. A., Pendley, B. D., Lindner, E., MARCO, R. D., Crespo, G. A., Acres, R. G., Walker, R., & Bishop, J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04625 · Cited by 86
Electrochemical DNA Hybridization Sensors Based on Conducting Polymers
Rahman, M. M., Li, X., Lopa, N. S., Ahn, S., & Lee, J. (2015) · Sensors · doi:10.3390/s150203801 · Cited by 91
“The transduction mechanism of poly(3,4-ethylenedioxythiophene) (PEDOT) was comprehensively studied using various electrochemical techniques, including electrochemical impedance spectroscopy (EIS) [117,118].”
MethodMattinen, U., & Bobacka, J. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.10.134 · Cited by 85
Self-citationKonopka, A., Sokalski, T., Michalska, A., Lewenstam, A., & Maj‐Żurawska, M. (2004) · Analytical Chemistry · doi:10.1021/ac0492158 · Cited by 85
Potentiometric Sensors with Carbon Black Supporting Platinum Nanoparticles
Paczosa‐Bator, B., Cabaj, L., Piech, R., & Skupień, K. (2013) · Analytical Chemistry · doi:10.1021/ac402885y · Cited by 85
Enabling Inkjet Printed Graphene for Ion Selective Electrodes with Postprint Thermal Annealing
He, Q., Das, S. R., Garland, N. T., Jing, D., Hondred, J. A., Cargill, A. A., Ding, S., Karunakaran, C., & Claussen, J. C. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b00092 · Cited by 96
Ion-Selective Electrodes with Solid Contact Based on Composite Materials: A Review
Wardak, C., Pietrzak, K., Morawska, K., & Grabarczyk, M. (2023) · Sensors · doi:10.3390/s23135839 · Cited by 84
“The chronopotentiometry technique can also be used to determine the resistance of the electrode, which often changes as a result of adding a solid contact material (Figure 2) [33].”
MethodGarland, N. T., Schmieder, J., Johnson, Z. T., Hjort, R. G., Chen, B., Andersen, C., Sanborn, D., Kjeldgaard, G., Pola, C. C., Li, J., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04665 · Cited by 90
All-solid-state reference electrodes based on conducting polymers
Kisiel, A., Marcisz, H., Michalska, A., & Maksymiuk, K. (2005) · The Analyst · doi:10.1039/b510868c · Cited by 84
Papp, S., Bojtár, M., Gyurcsányi, R. E., & Lindfors, T. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01587 · Cited by 83
Highly sensing and transducing materials for potentiometric ion sensors with versatile applicability
Huang, M., & Li, X. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100885 · Cited by 89
Conducting polymers revisited: applications in energy, electrochromism and molecular recognition
Wolfart, F., Hryniewicz, B. M., Góes, M. S., Corrêa, C. M., Torresi, R. M., Minadeo, M. A. O. S., de Torresi, S. I. C., de Oliveira, R. D., Marchesi, L. F. Q. P., & Vidotti, M. (2017) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-017-3556-9 · Cited by 82
Xu, J., Zhang, Z., Gan, S., Gao, H., Kong, H., Song, Z., Ge, X., Bao, Y., & Niu, L. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00960 · Cited by 82
Bieg, C., Fuchsberger, K., & Stelzle, M. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9945-6 · Cited by 81
“In addition, a reversible, well-defined, and fast redox system will contribute to stabilizing the potential [6, 16, 88, 94].”
BackgroundMethodInfluentialAn integrated sensing and wireless communications platform for sensing sodium in sweat
Matzeu, G., O'Quigley, C., McNamara, E., Zuliani, C., Fay, C., Glennon, T., & Diamond, D. (2016) · Analytical Methods · doi:10.1039/c5ay02254a · Cited by 80
Huang, Y., Wang, T., Xu, Z., Hughes, E., Qian, F., Lee, M., Fan, Y., Lei, Y., Brückner, C., & Li, B. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05928 · Cited by 86
Joon, N. K., He, N., Ruzgas, T. A., Bobacka, J., & Lisak, G. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01490 · Cited by 80
Self-citationA Printed Organic Amplification System for Wearable Potentiometric Electrochemical Sensors
Shiwaku, R., Matsui, H., Nagamine, K., Uematsu, M., Mano, T., Maruyama, Y., Nomura, A., Tsuchiya, K., Hayasaka, K., Takeda, Y., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22265-1 · Cited by 86
Ding, R., Krikstolaityte, V., & Lisak, G. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.03.079 · Cited by 78
Salem, A. A., Barsoum, B. N., & Izake, E. L. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.08.070 · Cited by 78
Capacitive Model for Coulometric Readout of Ion-Selective Electrodes
Jarolímová, Z., Han, T., Mattinen, U., Bobacka, J., & Bakker, E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02145 · Cited by 77
Self-citationPreparation and Characterization of Carbon Nano‐Onion/PEDOT:PSS Composites
Plonska-Brzezinska, M. E., Lewandowski, M., Błaszyk, M., Molina‐Ontoria, A., Lucinski, T., & Echegoyen, L. A. (2012) · ChemPhysChem · doi:10.1002/cphc.201200789 · Cited by 77
Hydrogel-Based Organic Subdural Electrode with High Conformability to Brain Surface
Oribe, S., Yoshida, S., Kusama, S., Osawa, S.-I., Nakagawa, A., Iwasaki, M., Tominaga, T., & Nishizawa, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49772-z · Cited by 85
Boeva, Z. A., & Lindfors, T. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.10.054 · Cited by 76
Metadata
- Authors
- Bobacka, J.
- Affiliations
- Åbo Akademi University (FI)
- Corresponding author
- Bobacka, Johan
- ORCID
- Bobacka, Johan
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4932-4937
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2000694408
- Cited by
- 686
- References
- 34
- Citations by year
- 2026: 29 · 2025: 33 · 2024: 54 · 2023: 39 · 2022: 46 · 2021: 49 · 2020: 47 · 2019: 51 · 2018: 33 · 2017: 28 · 2016: 23 · 2015: 23 · 2014: 23 · 2013: 19 · 2012: 25
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Åbo Akademi University Research Portal (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- potential stability, conducting polymers, ion-to-electron transduction, PEDOT, potassium ion-selective electrode, chronopotentiometry, electrochemical impedance spectroscopy, solvent polymeric membranes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.