The DOI matches its Crossref record.
Optical Nanosensors for Chemical Analysis inside Single Living Cells. 1. Fabrication, Characterization, and Methods for Intracellular Delivery of PEBBLE Sensors
Abstract
Spherical optical nanosensors, or PEBBLEs (probes encapsulated by biologically localized embedding), have been produced in sizes including 20 and 200 nm in diameter. These sensors are fabricated in a microemulsion and consist of fluorescent indicators entrapped in a polyacrylamide matrix. A generalized polymerization method has been developed that permits production of sensors containing any hydrophilic dye or combination of dyes in the matrix. The PEBBLE matrix protects the fluorescent dye from interference by proteins, allowing reliable in vivo calibrations of dyes. Sensor response times are less than 1 ms. Cell viability assays indicate that the PEBBLEs are biocompatible, with negligible biological effects compared to control conditions. Several sensor delivery methods have been studied, including liposomal delivery, gene gun bombardment, and picoinjection into single living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Nanomedicine: current status and future prospects
Moghimi, S. M., Hunter, A. C., & Murray, J. C. (2005) · The FASEB Journal · doi:10.1096/fj.04-2747rev · Cited by 2,029
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Physical approaches to biomaterial design
Mitragotri, S., & Lahann, J. (2009) · Nature Materials · doi:10.1038/nmat2344 · Cited by 1,445
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Implications of Nanobiosensors in Agriculture
Rai, V., Acharya, S., & Dey, N. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322039 · Cited by 332
Fluorescent nanoparticles for intracellular sensing: A review
Ruedas-Rama, M. J., Walters, J. D., Orte, A., & Hall, E. A. H. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.025 · Cited by 321
Levy, L., Sahoo, Y., Kim, K.-S., Bergey, E. J., & Prasad, P. N. (2002) · Chemistry of Materials · doi:10.1021/cm0203013 · Cited by 320
Recent development and applications of optical and fiber-optic pH sensors
Lin, J. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00034-0 · Cited by 271
Polymer microcapsules as mobile local pH-sensors
Kreft, O., Javier, A. M., Sukhorukov, G. B., & Parak, W. J. (2007) · Journal of Materials Chemistry · doi:10.1039/b705419j · Cited by 255
Hidalgo, G., Burns, A., Herz, E., Hay, A. G., Houston, P. L., Wiesner, U., & Lion, L. W. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.01220-09 · Cited by 127
Anticancer drug delivery with nanoparticles.
(2006) · PubMed · Cited by 68
Metadata
- Authors
- Clark, H. A., Hoyer, M., Philbert, M. A., & Kopelman, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-10-01
- Volume
- 71
- Issue
- 21
- Pages
- 4831-4836
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2009271486
- Cited by
- 355
- References
- 0
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.