The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Combined Scanning Electrochemical−Atomic Force Microscopy
Abstract
A combined scanning electrochemical microscope (SECM)-atomic force microscope (AFM) is described. The instrument permits the first simultaneous topographical and electrochemical measurements at surfaces, under fluid, with high spatial resolution. Simple probe tips suitable for SECM-AFM, have been fabricated by coating flattened and etched Pt microwires with insulating, electrophoretically deposited paint. The flattened portion of the probe provides a flexible cantilever (force sensor), while the coating insulates the probe such that only the tip end (electrode) is exposed to the solution. The SECM-AFM technique is illustrated with simultaneous electrochemical-probe deflection approach curves, simultaneous topographical and electrochemical imaging studies of track-etched polycarbonate ultrafiltration membranes, and etching studies of crystal surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Scanning Probe Microscopy and Spectroscopy: Methods and Applications
Wiesendanger, R. (1994) · Cambridge University Press eBooks · doi:10.1017/cbo9780511524356 · Cited by 1,645
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
The Scanning Ion-Conductance Microscope
Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B. (1989) · Science · doi:10.1126/science.2464851 · Cited by 849
Microfabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Scanning electrochemical microscopy. Theory of the feedback mode
Kwak, J., & Bard, A. J. (1989) · Analytical Chemistry · doi:10.1021/ac00186a009 · Cited by 594
Rugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Deformation and height anomaly of soft surfaces studied with an AFM
Weisenhorn, A. L., Khorsandi, M., Kasas, S., Gotzos, V, & Butt, H. J. (1993) · Nanotechnology · doi:10.1088/0957-4484/4/2/006 · Cited by 427
Fabrication and Use of Nanometer-Sized Electrodes in Electrochemistry
Penner, R. M., Heben, M. J., Longin, T. L., & Lewis, N. S. (1990) · Science · doi:10.1126/science.250.4984.1118 · Cited by 356
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Structural Transformation of Heterogeneous Materials for Electrocatalytic Oxygen Evolution Reaction
Ding, H., Liu, H., Chu, W., Wu, C., & Xie, Y. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00234 · Cited by 637
Local polarization dynamics in ferroelectric materials
Kalinin, S. V., Morozovska, A. N., Chen, L. Q., & Rodriguez, B. J. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/5/056502 · Cited by 419
Peng, C., Jin, J., & Chen, G. Z. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.07.004 · Cited by 366
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
Self-citationScanning electrochemical microscopy in the 21st century
Sun, P., Laforge, F. O., & Mirkin, M. V. (2007) · Phys. Chem. Chem. Phys. · doi:10.1039/b612259k · Cited by 310
A New View of Electrochemistry at Highly Oriented Pyrolytic Graphite
Patel, A. N., Collignon, M. G., O’Connell, M. A., Hung, W. O. Y., McKelvey, K., Macpherson, J. V., & Unwin, P. R. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308615h · Cited by 273
Self-citation
Metadata
- Authors
- Macpherson, J. V., & Unwin, P. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-10
- Volume
- 72
- Issue
- 2
- Pages
- 276-285
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2067477425
- Cited by
- 383
- References
- 16
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.