The DOI matches its Crossref record.
Raman Spectroscopic Imaging Markers for Fatigue-Related Microdamage in Bovine Bone
Abstract
Raman spectroscopic markers have been determined for fatigue-related microdamage in bovine bone. Microdamage was induced using a cyclic fatigue loading regime. After loading, the specimens were stained en-bloc with basic fuchsin to facilitate damage visualization and differentiate fatigue-induced damage from cracks generated during subsequent histological sectioning. Bone tissue specimens were examined by light microscopy and hyperspectral near-infrared Raman imaging microscopy. Three regions were defined-tissue with no visible damage, tissue with microcracks, and tissue with diffuse damage. Raman transects, lines of 150-200 Raman spectra, were used for initial tissue surveys. Exploratory factor analysis of the transect Raman spectra has identified spectroscopically distinct chemical microstructures of the bone specimens that correlate with damage. In selected regions of damage, full hyperspectral Raman images were obtained with 1.4-microm spatial resolution. In regions of undamaged tissue, the phosphate nu1 band is found at 957 cm(-1), as expected for the carbonated hydroxyapatic bone mineral. However, in regions of visible microdamage, an additional phosphate nu1 band is observed at 963 cm(-1) and interpreted as a more stoichiometric, less carbonated mineral species. Raman imaging confirms the qualitative relationship between the Raman spectral signature of bone mineral and the type of microdamage in bovine bone. Two tentative explanations for the presence of less carbonated phosphate in damaged regions are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Composition of bone and apatitic biomaterials as revealed by intravital Raman microspectroscopy
PENEL, G., DELFOSSE, C., DESCAMPS, M., & LEROY, G. (2005) · Bone · doi:10.1016/j.bone.2005.02.012 · Cited by 274
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
PTH signaling mediates perilacunar remodeling during exercise
Gardinier, J. D., Al-Omaishi, S., Morris, M. D., & Kohn, D. H. (2016) · Matrix Biology · doi:10.1016/j.matbio.2016.02.010 · Cited by 69
Self-citation
Metadata
- Authors
- Timlin, J. A., Carden, A., Morris, M. D., Rajachar, R. M., & Kohn, D. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-04-12
- Volume
- 72
- Issue
- 10
- Pages
- 2229-2236
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2063376705
- Cited by
- 187
- References
- 0
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman Spectroscopic Imaging Markers for Fatigue-Related Microdamage in Bovine Bone. https://app.cochat.ai/papers/10.1021/ac9913560
- The paper
- Timlin, J. A., Carden, A., Morris, M. D., Rajachar, R. M., & Kohn, D. H. (2000). Raman Spectroscopic Imaging Markers for Fatigue-Related Microdamage in Bovine Bone. Analytical Chemistry. https://doi.org/10.1021/ac9913560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.