The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Tissue-Specific Near-Infrared Fluorescence Imaging
Open accessAbstract
Near-infrared (NIR) fluorescence light has been widely utilized in clinical imaging by providing surgeons highly specific images of target tissue. The "NIR window" from 650 to 900 nm is especially useful due to several special features such as minimal autofluorescence and absorption of biomolecules in tissue, as well as low light scattering. Compared with visible wavelengths, NIR fluorescence light is invisible, thus allowing highly sensitivity real-time image guidance in human surgery without changing the surgical field. The benefit of using NIR fluorescence light as a clinical imaging technology can be attributed to its molecular fluorescence as an exogenous contrast agent. Indeed, whole body preoperative imaging of single-photon emission computed tomography (SPECT) and positron emission tomography (PET) remains important in diagnostic utility, but they lack the efficacy of innocuous and targeted NIR fluorophores to simultaneously facilitate the real-time delineation of diseased tissue while preserving vital tissues. Admittedly, NIR imaging technology has been slow to enter clinical use mostly due to the late-coming development of truly breakthrough contrast agents for use with current imaging systems. Therefore, clearly defining the physical margins of tumorous tissue remains of paramount importance in bioimaging and targeted therapy. An equally noteworthy yet less researched goal is the ability to outline healthy vital tissues that should be carefully navigated without transection during the intraoperative surgery. Both of these paths require optimizing a gauntlet of design considerations to obtain not only an effective imaging agent in the NIR window but also high molecular brightness, water solubility, biocompatibility, and tissue-specific targetability. The imaging community recognizes three strategic approaches which include (1) passive targeting via the EPR effect, (2) active targeting using the innate overall biodistribution of known molecules, and (3) activatable targeting through an internal stimulus, which turns on fluorescence from an off state. Recent advances in nanomedicine and bioimaging offer much needed promise toward fulfilling these stringent requirements as we develop a successful catalog of targeted contrast agents for illuminating both tumors and vital tissues in the same surgical space by employing spectrally distinct fluorophores in real time. These tissue-specific contrast agents can be versatile arsenals to physicians for real-time intraoperative navigation as well as image-guided targeted therapy. There is a versatile library of tissue-specific fluorophores available in the literature, with many discussed herein, which offers clinicians an array of possibilities that will undoubtedly improve intraoperative success and long-term postoperation prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Doxil® — The first FDA-approved nano-drug: Lessons learned
Barenholz, Y. (. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.03.020 · Cited by 4,792
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Targeted zwitterionic near-infrared fluorophores for improved optical imaging
Choi, H. S., Gibbs, S. L., Lee, J. H., Kim, S. H., Ashitate, Y., Liu, F., Hyun, H., Park, G., Xie, Y., Bae, S., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2468 · Cited by 560
Self-citationDual-Function Probe for PET and Near-Infrared Fluorescence Imaging of Tumor Vasculature
Cai, W., Chen, K., Li, Z.-B., Gambhir, S. S., & Chen, X. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.043216 · Cited by 429
Tian, J., Ding, L., Xu, H.-J., Shen, Z., Ju, H., Jia, L., Bao, L., & Yu, J.-S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408286k · Cited by 416
Compact Cysteine-Coated CdSe(ZnCdS) Quantum Dots for in Vivo Applications
Liu, W., Choi, H. S., Zimmer, J. P., Tanaka, E., Frangioni, J. V., & Bawendi, M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073790m · Cited by 415
Self-citationEfficiency of Anti-Stokes Fluorescence in Dyes
Jablonski, A. (1933) · Nature · doi:10.1038/131839b0 · Cited by 395
Cited by
Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
Huang, J., Li, J., Lyu, Y., Miao, Q., & Pu, K. (2019) · Nature Materials · doi:10.1038/s41563-019-0378-4 · Cited by 721
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Carbon dots: Biomacromolecule interaction, bioimaging and nanomedicine
Peng, Z., Han, X., Li, S., Al-Youbi, A. O., Bashammakh, A. S., El-Shahawi, M. S., & Leblanc, R. M. (2017) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.001 · Cited by 411
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
Metadata
- Authors
- Owens, E. A., Henary, M., El Fakhri, G., & Choi, H. S.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-08-26
- Volume
- 49
- Issue
- 9
- Pages
- 1731-1740
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2510572562
- Cited by
- 414
- References
- 32
- FWCI
- 28.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue-Specific Near-Infrared Fluorescence Imaging. https://app.cochat.ai/papers/10.1021/acs.accounts.6b00239
- The paper
- Owens, E. A., Henary, M., El Fakhri, G., & Choi, H. S. (2016). Tissue-Specific Near-Infrared Fluorescence Imaging. Accounts of Chemical Research. https://doi.org/10.1021/acs.accounts.6b00239
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.