CoChat

Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms

The DOI matches its Crossref record; 38 of the 40 references it cites were found in a registry or an index.

Abstract

Physiological sensors in a wearable form have rapidly emerged on the market due to technological breakthroughs and have become nearly ubiquitous with the Apple Watch, FitBit, and other wearable devices. While these wearables mostly monitor simple biometric signatures, new devices that can report on the human readiness level through sensing molecular biomarkers are critical to optimizing the human factor in both commercial sectors and the Department of Defense. The military is particularly interested in real-time, wearable, minimally invasive monitoring of fatigue and human performance to improve the readiness and performance of the war fighter. However, very few devices have ventured into the realm of reporting directly on biomarkers of interest. Primarily this is because of the difficulties of sampling biological fluids in real-time and providing accurate readouts using highly selective and sensitive sensors. When additional restrictions to only use sweat, an excretory fluid, are enforced to minimize invasiveness, the demands on sensors becomes even greater due to the dilution of the biomarkers of interest, as well as variability in salinity, pH, and other physicochemical variables which directly impact the read-out of real-time biosensors. This Account will provide a synopsis not only on exemplary demonstrations and technological achievements toward implementation of real-time, wearable sweat sensors but also on defining problems that still remain toward implementation in wearable devices that can detect molecular biomarkers for real world applications. First, the authors describe the composition of minimally invasive biofluids and then identify what biomarkers are of interest as biophysical indicators. This Account then reviews demonstrated techniques for extracting biofluids from the site of generation and transport to the sensor developed by the authors. Included in this discussion is a detailed description on biosensing recognition elements and transducers developed by the authors to enable generation of selective electrochemical sensing platforms. The authors also discuss ongoing efforts to identify biorecognition elements and the chemistries necessary to enable high affinity, selective biorecognition elements. Finally, this Account presents the requirements for wearable, real-time sensors to be (1) highly stable, (2) portable, (3) reagentless, (4) continuous, and (5) responsive in real-time, before delving into specific methodologies to sense classes of biomarkers that have been explored by academia, government laboratories, and industry. Each platform has its areas of greatest utility, but also come with corresponding weaknesses: (1) ion selective electrodes are robust and have been demonstrated in wearables but are limited to detection of ions, (2) enzymatic sensors enable indirect detection of metabolites and have been demonstrated in wearables, but the compounds that can be detected are limited to a subset of small molecules and the sensors are sensitive to flow, (3) impedance-based sensors can detect a wide range of compounds but require further research and development for deployment in wearables. In conclusion, while substantial progress has been made toward wearable molecular biosensors, substantial barriers remain and need to be solved to enable deployment of minimally invasive, wearable biomarker monitoring devices that can accurately report on psychophysiological status.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.accounts.8b00555

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Research works printed but not linked: 2

  1. Heikenfeld J., 2019, Nat. Biotechnol.
  2. Bühlmann P., 2012, Supramolecular Chemistry: From Molecules to Nanomaterials, 2539

Cited by

See all 210

Metadata

Authors
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S.
Affiliations
  • United States Air Force Research Laboratory (US)
  • University of Cincinnati (US)
Corresponding author
Kim, Steve S.
Venue
Accounts of Chemical Research
Published
2019-01-28
Volume
52
Issue
2
Pages
297-306
ISSN
  • 0001-4842 (ISSN-L)
  • 1520-4898
OpenAlex
W2911438952
Cited by
207
References
40
Citations by year
2026: 24 · 2025: 42 · 2024: 32 · 2023: 31 · 2022: 26 · 2021: 26 · 2020: 19 · 2019: 7
FWCI
7.01
Type
journal article
Language
en
Open access
closed
Locations
  • Accounts of Chemical Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Novartis
  • Los Alamos National Laboratory
  • Air Force Research Laboratory
  • Division of Industrial Innovation and Partnerships (IIP-1738617)
  • Genentech
  • Amgen
  • GlaxoSmithKline
  • Teknologian Tutkimuskeskus VTT
  • U.S. Air Force
  • ESI Group
  • Corteva Agriscience
  • ALine, Inc.
  • Corning Incorporated
  • Beckman Coulter, Inc.
  • KWS SAAT SE
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
sweat sensors, wearable biosensors, real-time sensing, sweat biomarkers, human performance monitoring, ion-selective electrodes, enzyme biosensor, electrochemical sensor, optical sensors, electrochemical impedance spectroscopy, potentiometric sensors, continuous monitoring, biorecognition elements, sweat pH, sweat osmolality
MeSH terms
Wearable Electronic Devices, Humans, Monitoring, Physiologic, Sweat, Biosensing Techniques, Biomarkers, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.