Characterization of Intact Antibody Drug Conjugate Variants Using Microfluidic Capillary Electrophoresis–Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this work, we utilize capillary electrophoresis-mass spectrometry (CE-MS) in an integrated microfluidic platform to analyze an intact, lysine-linked antibody drug conjugate (ADC) in order to assess post translational modifications and drug load variants. The initial charge heterogeneity of the unconjugated IgG-2 monoclonal antibody (mAb) was assessed by separating intact charge variants. Three main charge variants were resolved in the CE dimension. These variants were attributed to pyroglutamic acid formation and decarboxylation on the primary structure of the mAb through characteristic mass shifts and changes in electrophoretic mobility. Additionally, glycoforms of the antibody charge variants were identified in the deconvoluted mass spectra. The observed glycoforms and their distribution compared favorably to a released N-glycan analysis performed on the mAb. After conjugation, the ADC was analyzed using the same microchip CE-MS method. The addition of a drug load resulted in a decrease in mobility and an increase in mass of 3145 Da. Five main species that differed in their respective drug-to-antibody ratios (DAR) were fully resolved in the CE separation, with each DAR displaying the same variant population observed on the unconjugated mAb. A DAR range of 0-4 was observed with an average of 1.7 drug loads. The DAR distribution generated from the microfluidic CE-MS data compared favorably to results from infusion-ESI-MS and imaging CE (iCE) analysis of the ADC, techniques commonly used for intact mAb and ADC characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Redman, E. A., Batz, N. G., Mellors, J. S., & Ramsey, J. M. (2015) · Analytical Chemistry · doi:10.1021/ac503964j · Cited by 136
Self-citation
Cited by
Capillary Electrophoresis Separations of Glycans
Lu, G., Crihfield, C. L., Gattu, S., Veltri, L. M., & Holland, L. A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00669 · Cited by 174
Recent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Týčová, A., Ledvina, V., & Klepárník, K. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600366 · Cited by 99
Belov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
“held together by non-covalent interactions instead of disulfide bonds [60, 61].”
Belov, A. M., Zang, L., Sebastiano, R., Santos, M. R., Bush, D. R., Karger, B. L., & Ivanov, A. R. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800067 · Cited by 88
Jooß, K., Hühner, J., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0542-0 · Cited by 79
Metadata
- Authors
- Redman, E. A., Mellors, J. S., Starkey, J. A., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-29
- Volume
- 88
- Issue
- 4
- Pages
- 2220-2226
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2304651759
- Cited by
- 112
- References
- 1
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.