Small Emitter Tips for Native Mass Spectrometry of Proteins and Protein Complexes from Nonvolatile Buffers That Mimic the Intracellular Environment
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Salts are often necessary to maintain the native structures and functions of many proteins and protein complexes, but many buffers adversely affect protein analysis by native mass spectrometry (MS). Here, protein and protein complex ions are formed directly from a 150 mM KCl and 25 mM Tris-HCl buffer at pH 7 that is widely used in protein chemistry to mimic the intracellular environment. The protein charge-state distributions are not resolved from electrospray ionization MS using 1.6 μm diameter emitter tips, resulting in no mass information. In contrast, the charge-state distributions are well-resolved using 0.5 μm tips, from which the masses of proteins and protein complexes can be obtained. Adduction of salt to protein ions decreases with decreasing tip size below ∼1.6 μm but not above this size. This suggests that the mechanism for reducing salt adduction is the formation of small initial droplets with on average fewer than one protein molecule per droplet, which lowers the salt:protein ratio in droplets that contain a protein molecule. This is the first demonstration of native mass spectrometry of protein and protein complex ions formed from a buffer containing physiological ionic strengths of nonvolatile salts that mimics the intracellular environment, and this method does not require sample preparation or addition of reagents to the protein solution before or during mass analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, submicron ESI emitter tips, developed by the Williams group, have pushed the boundaries of ESI sensitivity while also showing improved salt tolerance up to physiological concentrations (25 mM Tris, 150 mM KCl) by virtue of creating smaller droplets [93].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [93]
Citations
Cites
UniProt: a hub for protein information
The UniProt Consortium (2015) · Nucleic Acids Research · doi:10.1093/nar/gku989 · Cited by 5,106
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
How Hofmeister ion interactions affect protein stability
Baldwin, R. L. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79404-3 · Cited by 1,124
Hofmeister Phenomena: An Update on Ion Specificity in Biology
Lo Nostro, P., & Ninham, B. W. (2012) · Chemical Reviews · doi:10.1021/cr200271j · Cited by 1,002
Structural changes in the calcium pump accompanying the dissociation of calcium
Toyoshima, C., & Nomura, H. (2002) · Nature · doi:10.1038/nature00944 · Cited by 894
Molecular Physiology and Pathophysiology of Electroneutral Cation-Chloride Cotransporters
Gamba, G. (2005) · Physiological Reviews · doi:10.1152/physrev.00011.2004 · Cited by 810
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Current and droplet size in the electrospraying of liquids. Scaling laws
Gañán-Calvo, A. M., Dávila, J., & Barrero, A. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00433-8 · Cited by 780
Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Research works printed but not linked: 1
- Srikanth A., 2009, Open Appl. Phys. J., 53
Cited by
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
VanAernum, Z. L., Busch, F., Jones, B. J., Jia, M., Chen, Z., Boyken, S. E., Sahasrabuddhe, A., Baker, D., & Wysocki, V. H. (2020) · Nature Protocols · doi:10.1038/s41596-019-0281-0 · Cited by 169
Protein–Small Molecule Interactions in Native Mass Spectrometry
Bennett, J. L., Nguyen, G. T. H., & Donald, W. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00293 · Cited by 168
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Native Mass Spectrometry: Recent Progress and Remaining Challenges
Karch, K. R., Snyder, D. T., Harvey, S. R., & Wysocki, V. H. (2022) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-092721-085421 · Cited by 150
Native Mass Spectrometry from Common Buffers with Salts That Mimic the Extracellular Environment
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702330 · Cited by 128
Self-citationNative Mass Spectrometry of Membrane Proteins
Keener, J. E., Zhang, G., & Marty, M. T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04342 · Cited by 126
Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand–Protein Binding Affinities
Nguyen, G. T. H., Tran, T. N., Podgorski, M. N., Bell, S. G., Supuran, C. T., & Donald, W. A. (2019) · ACS Central Science · doi:10.1021/acscentsci.8b00787 · Cited by 125
Mass spectrometry using electrospray ionization
Prabhu, G. R. D., Williams, E. R., Wilm, M. S., & Urban, P. L. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00203-4 · Cited by 145
Self-citationProteomes Are of Proteoforms: Embracing the Complexity
Carbonara, K., Andonovski, M., & Coorssen, J. R. (2021) · Proteomes · doi:10.3390/proteomes9030038 · Cited by 112
Mass spectrometry-enabled structural biology of membrane proteins
Calabrese, A. N., & Radford, S. E. (2018) · Methods · doi:10.1016/j.ymeth.2018.02.020 · Cited by 92
Kempa, E. E., Hollywood, K. A., Smith, C. A., & Barran, P. E. (2018) · The Analyst · doi:10.1039/c8an01448e · Cited by 98
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Self-citationNative mass spectrometry—A valuable tool in structural biology
Barth, M., & Schmidt, C. (2020) · Journal of Mass Spectrometry · doi:10.1002/jms.4578 · Cited by 99
Poltash, M. L., McCabe, J. W., Shirzadeh, M., Laganowsky, A., Clowers, B. H., & Russell, D. H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b02463 · Cited by 79
Approaches to Heterogeneity in Native Mass Spectrometry
Rolland, A. D., & Prell, J. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00696 · Cited by 83
Effect of droplet lifetime on where ions are formed in electrospray ionization
Xia, Z., & Williams, E. R. (2018) · The Analyst · doi:10.1039/c8an01824c · Cited by 73
Self-citationStudying protein structure and function by native separation–mass spectrometry
van Schaick, G., Haselberg, R., Somsen, G. W., Wuhrer, M., & Domínguez‐Vega, E. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00353-7 · Cited by 71
The role of analyte concentration in accelerated reaction rates in evaporating droplets
Chen, C. J., & Williams, E. R. (2023) · Chemical Science · doi:10.1039/d3sc00259d · Cited by 65
Self-citationSchwenzer, A., Kruse, L., Jooß, K., & Neusüß, C. (2023) · PROTEOMICS · doi:10.1002/pmic.202300135 · Cited by 63
Liu, R., Xia, S., & Li, H. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21793 · Cited by 66
Susa, A. C., Lippens, J. L., Xia, Z., Loo, J. A., Campuzano, I. D. G., & Williams, E. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1793-x · Cited by 60
Self-citationHigh-Throughput Native Mass Spectrometry Screening in Drug Discovery
Gavriilidou, A. F. M., Sokratous, K., Yen, H., & Colibus, L. D. (2022) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2022.837901 · Cited by 69
Metal Ion Binding to the Amyloid β Monomer Studied by Native Top-Down FTICR Mass Spectrometry
Lermyte, F., Everett, J., Lam, Y. P. Y., Wootton, C. A., Brooks, J., Barrow, M. P., Telling, N. D., Sadler, P. J., O’Connor, P. B., & Collingwood, J. F. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02283-7 · Cited by 57
Tips on Making Tiny Tips: Secrets to Submicron Nanoelectrospray Emitters
Jordan, J. S., Xia, Z., & Williams, E. R. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00372 · Cited by 54
Self-citationHarper, C. C., Brauer, D. D., Francis, M. B., & Williams, E. R. (2021) · Chemical Science · doi:10.1039/d0sc05707j · Cited by 54
Self-citationKulyk, D. S., Swiner, D. J., Sahraeian, T., & Badu-Tawiah, A. K. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01456 · Cited by 49
Exploring the structure and dynamics of macromolecular complexes by native mass spectrometry
Boeri Erba, E., Signor, L., & Petosa, C. (2020) · Journal of Proteomics · doi:10.1016/j.jprot.2020.103799 · Cited by 51
Lara-Ortega, F. J., Robles‐Molina, J., Brandt, S., Schütz, A., Gilbert‐López, B., Molina‐Díaz, A., García-Reyes, J. F., & Franzke, J. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.077 · Cited by 47
Submicron Emitters Enable Reliable Quantification of Weak Protein–Glycan Interactions by ESI-MS
Bolívar, E. G. B., Bui, D. T., Kitova, E. N., Han, L., Zheng, R. B., Luber, E. J., Sayed, S. Y., Mahal, L. K., & Klassen, J. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c05003 · Cited by 50
Electrophoretic Desalting To Improve Performance in Electrospray Ionization Mass Spectrometry
Zhang, Z., Pulliam, C. J., Flick, T. G., & Cooks, R. G. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04529 · Cited by 46
Kenderdine, T., Xia, Z., Williams, E. R., & Fabris, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03632 · Cited by 52
Self-citationIntact living-cell electrolaunching ionization mass spectrometry for single-cell metabolomics
Shao, Y., Zhou, Y., Liu, Y., Zhang, W., Zhu, G., Zhao, Y., Zhang, Q., Yao, H., Zhao, H., Guo, G., et al. (2022) · Chemical Science · doi:10.1039/d2sc02569h · Cited by 46
Jooß, K., Schachner, L. F., Watson, R., Gillespie, Z. B., Howard, S. A., Cheek, M. A., Meiners, M. J., Sobh, A., Licht, J. D., Keogh, M., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04975 · Cited by 44
Xia, Z., DeGrandchamp, J. B., & Williams, E. R. (2019) · The Analyst · doi:10.1039/c9an00266a · Cited by 46
Self-citationHarper, C. C., Miller, Z. M., McPartlan, M. S., Jordan, J. S., Pedder, R. E., & Williams, E. R. (2023) · ACS Nano · doi:10.1021/acsnano.3c00539 · Cited by 40
Self-citationField Effect Transistor Biosensors for Healthcare Monitoring (4/2024)
Zhang, Z., Hu, J., Lin, S., Wu, J., Xia, F., & Lou, X. (2024) · Interdisciplinary medicine · doi:10.1002/inmd.20240032 · Cited by 56
Mass spectrometry-based metabolomic as a powerful tool to unravel the component and mechanism in TCM
Liao, G., Tang, H., Yu, Y., Fu, L., Li, S.-J., & Zhu, M. (2025) · Chinese Medicine · doi:10.1186/s13020-025-01112-2 · Cited by 44
Wang, Y., Sun, M., Qiao, J., Ouyang, J., & Na, N. (2017) · Chemical Science · doi:10.1039/c7sc04259k · Cited by 38
Nguyen, G. T. H., Nocentini, A., Angeli, A., Gratteri, P., Supuran, C. T., & Donald, W. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00163 · Cited by 42
Effects of Electrospray Droplet Size on Analyte Aggregation: Evidence for Serine Octamer in Solution
Jordan, J. S., & Williams, E. R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04343 · Cited by 37
Self-citationNative Mass Spectrometry and Nucleic Acid G-Quadruplex Biophysics: Advancing Hand in Hand
Gabelica, V. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.1c00396 · Cited by 39
Breakage of the oligomeric CaMKII hub by the regulatory segment of the kinase
Karandur, D., Bhattacharyya, M., Xia, Z., Lee, Y. K., Muratcioglu, S., McAffee, D., McSpadden, E. D., Qiu, B., Groves, J. T., Williams, E. R., et al. (2020) · eLife · doi:10.7554/elife.57784 · Cited by 35
“The submicron emitters were chosen to help reduce salt adducts on the protein ions and to reduce the chemical noise (Susa et al., 2017).”
BackgroundSelf-citationStructural mass spectrometry goes viral
Dülfer, J., Kádek, A., Kopicki, J.-D., Krichel, B., & Uetrecht, C. (2019) · Advances in virus research · doi:10.1016/bs.aivir.2019.07.003 · Cited by 39
Xia, Z., & Williams, E. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1825-6 · Cited by 33
Self-citationDevelopment of a target identification approach using native mass spectrometry
Liu, M., Voorhis, W. C. V., & Quinn, R. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-81859-4 · Cited by 32
Lee, K. J., Jordan, J. S., & Williams, E. R. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.4c03415 · Cited by 32
Self-citationMoreno‐González, D., Alcántara-Durán, J., Gilbert‐López, B., García-Reyes, J. F., & Molina‐Díaz, A. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.09.006 · Cited by 29
Peris‐Díaz, M. D., Guráň, R., Zítka, O., Adam, V., & Krężel, A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01604 · Cited by 29
On-Demand Mass Spectrometry Analysis by Miniature Mass Spectrometer
Wu, J., Zhang, W., & Ouyang, Z. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00575 · Cited by 28
Cleary, S. P., & Prell, J. S. (2019) · ChemPhysChem · doi:10.1002/cphc.201900022 · Cited by 29
Han, Z., & Chen, L. C. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00322 · Cited by 26
Jordan, J. S., Harper, C. C., Zhang, F., Kofman, E., Li, M., Sathiyamoorthy, K., Zaragoza, J. P. T., Fayadat‐Dilman, L., & Williams, E. R. (2024) · Journal of the American Chemical Society · doi:10.1021/jacs.4c05885 · Cited by 27
Self-citationStandardized workflow for multiplexed charge detection mass spectrometry on orbitrap analyzers
Su, P., McGee, J. P., Hollas, M. A. R., Fellers, R. T., Durbin, K. R., Greer, J. B., Early, B. P., Yip, P. F., Zabrouskov, V., Srzentić, K., et al. (2025) · Nature Protocols · doi:10.1038/s41596-024-01091-y · Cited by 25
Panczyk, E. M., Gilbert, J. D., Jagdale, G. S., Stiving, A. Q., Baker, L. A., & Wysocki, V. H. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03666 · Cited by 23
Screening of protein-ligand interactions under crude conditions by native mass spectrometry
Takano, K., Arai, S., Sakamoto, S., Ushijima, H., Ikegami, T., Saikusa, K., Konuma, T., Hamachi, I., & Akashi, S. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02649-x · Cited by 23
Prabhu, G. R. D., Ponnusamy, V. K., Witek, H. A., & Urban, P. L. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01945 · Cited by 23
Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry
Harper, C. C., Miller, Z. M., Lee, H., Bischoff, A. J., Francis, M. B., Schaffer, D. V., & Williams, E. R. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02572 · Cited by 25
Self-citationSeeing the complete picture: proteins in top-down mass spectrometry
Habeck, T., & Lermyte, F. (2022) · Essays in Biochemistry · doi:10.1042/ebc20220098 · Cited by 25
Cui, M., & Du, Y. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117701 · Cited by 25
Chen, C. J., Avadhani, V. S., & Williams, E. R. (2025) · Angewandte Chemie International Edition · doi:10.1002/anie.202424662 · Cited by 24
Self-citationKarki, S., Shi, F., Archer, J. J., Sistani, H., & Levis, R. J. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-1893-2 · Cited by 22
Mitra, G. (2019) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2019.07.013 · Cited by 23
Single-Cell Native Mass Spectrometry of Human Erythrocytes
Sakamoto, W., Azegami, N., Konuma, T., & Akashi, S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00588 · Cited by 21
Sizing sub-diffraction limit electrosprayed droplets by structured illumination microscopy
Hollerbach, A., Logsdon, D. L., Iyer, K., Li, A., Schaber, J. A., & Cooks, R. G. (2017) · The Analyst · doi:10.1039/c7an01278k · Cited by 20
Wang, H., Yong, G., Brown, S. L., Lee, H. E., Zenaidee, M. A., Supuran, C. T., & Donald, W. A. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.075 · Cited by 20
Bischoff, A. J., Harper, C. C., Williams, E. R., & Francis, M. B. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c09160 · Cited by 21
Self-citationMass Spectrometry-Based Structural Proteomics for Metal Ion/Protein Binding Studies
Lin, Y., & Gross, M. L. (2022) · Biomolecules · doi:10.3390/biom12010135 · Cited by 19
Lighting Up at High Potential: Effects of Voltage and Emitter Size in Nanoelectrospray Ionization
Jordan, J. S., Miller, Z. M., Harper, C. C., Hanozin, E., & Williams, E. R. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00121 · Cited by 19
Self-citationNative Mass Spectrometry of Protein and DNA Complexes Prepared in Nonvolatile Buffers
Saikusa, K., Kato, D., Nagadoi, A., Kurumizaka, H., & Akashi, S. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00145 · Cited by 18
Miller, Z. M., Narsineni, L., Li, Y., Gardner, M. R., Torpey, J. W., & Williams, E. R. (2025) · Journal of Controlled Release · doi:10.1016/j.jconrel.2025.113856 · Cited by 19
Self-citationHarper, C. C., Miller, Z. M., & Williams, E. R. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c03160 · Cited by 17
Self-citationDesalting strategies for native mass spectrometry
Li, Y., Li, W., Zheng, Y., Wang, T., Pu, R., & Zhang, Z. (2024) · Talanta · doi:10.1016/j.talanta.2024.126824 · Cited by 18
Wang, X., Li, N., Xu, D., Yang, X., Zhu, Q., Xiao, D., & Lü, N. (2018) · Talanta · doi:10.1016/j.talanta.2018.07.066 · Cited by 17
Thermometer Ions, Internal Energies, and In‐Source Fragmentation in Ambient Ionization
Bertrand, É., & Gabelica, V. (2025) · Mass Spectrometry Reviews · doi:10.1002/mas.21924 · Cited by 16
On the intersection of electrochemistry and mass spectrometry
Baker, L. A., & Jagdale, G. S. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.12.001 · Cited by 16
Chen, W., Gao, Z., Chu, F., He, Q., Gao, Y., Liu, Y., Feng, H., & Pan, Y. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02919 · Cited by 16
A 3D-Printed Offline Nano-ESI Source for Bruker MS Instruments
Götze, M., Polewski, Ł., Bechtella, L., & Pagel, K. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00214 · Cited by 16
Conducting and characterizing femto flow electrospray ionization
Li, H., Allen, N. R., Li, M., & Li, A. (2022) · The Analyst · doi:10.1039/d1an02190g · Cited by 15
Walz, A., Stoiber, K., Huettig, A., Schlichting, H., & Barth, J. V. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04495 · Cited by 16
Chen, L. C., Naito, T., Ninomiya, S., & Hiraoka, K. (2018) · The Analyst · doi:10.1039/c8an01113c · Cited by 15
Kim, H. J., & Gallagher, E. S. (2020) · The Analyst · doi:10.1039/d0an00135j · Cited by 15
Chen, Y., Yuan, S., Liu, Y., & Huang, G. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.10.036 · Cited by 15
Sharif, D., Foroushani, S. H., Attanayake, K., Dewasurendra, V. K., DeBastiani, A., DeVor, A., Johnson, M. B., Li, P., & Valentine, S. J. (2022) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.2c04960 · Cited by 15
Gadzuk-Shea, M. M., Hubbard, E. E., Gozzo, T. A., & Bush, M. F. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00147 · Cited by 16
Nested-channel for on-demand alternation between electrospray ionization regimes
Li, M., Li, H., Allen, N. R., Wang, T., Li, L., Schwartz, J. C., & Li, A. (2020) · Chemical Science · doi:10.1039/d0sc06221a · Cited by 14
Szabó, R., Nagy, C., & Gáspár, A. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202318225 · Cited by 17
Han, Z., & Chen, L. C. (2022) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2022.116845 · Cited by 13
Sternicki, L. M., & Poulsen, S. (2025) · RSC Medicinal Chemistry · doi:10.1039/d5md00617a · Cited by 12
Lee, K. W., Harrilal, C., Fu, L., Eakins, G. S., & McLuckey, S. A. (2020) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2020.116437 · Cited by 13
Pimlott, D. J. D., & Konermann, L. (2021) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2021.116678 · Cited by 20
Chen, L. C. (2019) · Mass Spectrometry · doi:10.5702/massspectrometry.s0079 · Cited by 12
Native Mass Spectrometry from Common Buffers with Salts That Mimic the Extracellular Environment
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Angewandte Chemie · doi:10.1002/ange.201702330 · Cited by 12
Self-citationFuller, C. N., Tose, L. V., Vitorino, F. N. D. L., Bhanu, N. V., Panczyk, E. M., Park, M. A., Garcia, B. A., & Fernandez-Lima, F. A. (2024) · Journal of Proteome Research · doi:10.1021/acs.jproteome.4c00177 · Cited by 13
LILBID-MS: using lasers to shed light on biomolecular architectures
Hellwig, N., Martin, J., & Morgner, N. (2022) · Biochemical Society Transactions · doi:10.1042/bst20190881 · Cited by 14
Laser Heating Nanoelectrospray Emitters for Fast Protein Melting Measurements with Mass Spectrometry
Jordan, J. S., & Williams, E. R. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04204 · Cited by 11
Self-citationLi, Z., Kitov, P. I., Kitova, E. N., Mozenah, F., Rodrigues, E., Chapla, D. G., Moremen, K. W., Macauley, M. S., & Klassen, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05007 · Cited by 12
Toward Nanopore Electrospray Mass Spectrometry: Nanopore Effects in the Analysis of Bacteria
Zhang, Y., Tang, Y., Tan, C., & Xu, W. L. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00622 · Cited by 12
Metadata
- Authors
- Susa, A. C., Xia, Z., & Williams, E. R.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Williams, Evan R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-22
- Volume
- 89
- Issue
- 5
- Pages
- 3116-3122
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2586632373
- Cited by
- 167
- References
- 59
- Citations by year
- 2026: 9 · 2025: 22 · 2024: 20 · 2023: 13 · 2022: 23 · 2021: 19 · 2020: 25 · 2019: 12 · 2018: 13 · 2017: 11
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM097357)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- native mass spectrometry, protein complexes, electrospray ionization, intracellular environment, charge state distribution, droplet formation
- MeSH terms
- Alcohol Dehydrogenase, Animals, Buffers, Cattle, Proteins, Saccharomyces cerevisiae, Salts, Serum Albumin, Bovine, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.