CoChat

Small Emitter Tips for Native Mass Spectrometry of Proteins and Protein Complexes from Nonvolatile Buffers That Mimic the Intracellular Environment

Susa, Anna C., Xia, Zijie, Williams, Evan R. · 2017 · Analytical Chemistry

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

Salts are often necessary to maintain the native structures and functions of many proteins and protein complexes, but many buffers adversely affect protein analysis by native mass spectrometry (MS). Here, protein and protein complex ions are formed directly from a 150 mM KCl and 25 mM Tris-HCl buffer at pH 7 that is widely used in protein chemistry to mimic the intracellular environment. The protein charge-state distributions are not resolved from electrospray ionization MS using 1.6 μm diameter emitter tips, resulting in no mass information. In contrast, the charge-state distributions are well-resolved using 0.5 μm tips, from which the masses of proteins and protein complexes can be obtained. Adduction of salt to protein ions decreases with decreasing tip size below ∼1.6 μm but not above this size. This suggests that the mechanism for reducing salt adduction is the formation of small initial droplets with on average fewer than one protein molecule per droplet, which lowers the salt:protein ratio in droplets that contain a protein molecule. This is the first demonstration of native mass spectrometry of protein and protein complex ions formed from a buffer containing physiological ionic strengths of nonvolatile salts that mimics the intracellular environment, and this method does not require sample preparation or addition of reagents to the protein solution before or during mass analysis.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.6b04897

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 1

  1. Srikanth A., 2009, Open Appl. Phys. J., 53

Cited by

Metadata

Authors
Susa, A. C., Xia, Z., & Williams, E. R.
Affiliations
University of California, Berkeley (US)
Corresponding author
Williams, Evan R.
Venue
Analytical Chemistry
Published
2017-02-22
Volume
89
Issue
5
Pages
3116-3122
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2586632373
Cited by
167
References
59
Citations by year
2026: 9 · 2025: 22 · 2024: 20 · 2023: 13 · 2022: 23 · 2021: 19 · 2020: 25 · 2019: 12 · 2018: 13 · 2017: 11
FWCI
8.24
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (R01GM097357)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
Keywords
native mass spectrometry, protein complexes, electrospray ionization, intracellular environment, charge state distribution, droplet formation
MeSH terms
Alcohol Dehydrogenase, Animals, Buffers, Cattle, Proteins, Saccharomyces cerevisiae, Salts, Serum Albumin, Bovine, Spectrometry, Mass, Electrospray Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.