Small Emitter Tips for Native Mass Spectrometry of Proteins and Protein Complexes from Nonvolatile Buffers That Mimic the Intracellular Environment
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Salts are often necessary to maintain the native structures and functions of many proteins and protein complexes, but many buffers adversely affect protein analysis by native mass spectrometry (MS). Here, protein and protein complex ions are formed directly from a 150 mM KCl and 25 mM Tris-HCl buffer at pH 7 that is widely used in protein chemistry to mimic the intracellular environment. The protein charge-state distributions are not resolved from electrospray ionization MS using 1.6 μm diameter emitter tips, resulting in no mass information. In contrast, the charge-state distributions are well-resolved using 0.5 μm tips, from which the masses of proteins and protein complexes can be obtained. Adduction of salt to protein ions decreases with decreasing tip size below ∼1.6 μm but not above this size. This suggests that the mechanism for reducing salt adduction is the formation of small initial droplets with on average fewer than one protein molecule per droplet, which lowers the salt:protein ratio in droplets that contain a protein molecule. This is the first demonstration of native mass spectrometry of protein and protein complex ions formed from a buffer containing physiological ionic strengths of nonvolatile salts that mimics the intracellular environment, and this method does not require sample preparation or addition of reagents to the protein solution before or during mass analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, submicron ESI emitter tips, developed by the Williams group, have pushed the boundaries of ESI sensitivity while also showing improved salt tolerance up to physiological concentrations (25 mM Tris, 150 mM KCl) by virtue of creating smaller droplets [93].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [93]
Citations
Cites
UniProt: a hub for protein information
The UniProt Consortium (2015) · Nucleic Acids Research · doi:10.1093/nar/gku989 · Cited by 5,106
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
How Hofmeister ion interactions affect protein stability
Baldwin, R. L. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79404-3 · Cited by 1,124
Hofmeister Phenomena: An Update on Ion Specificity in Biology
Lo Nostro, P., & Ninham, B. W. (2012) · Chemical Reviews · doi:10.1021/cr200271j · Cited by 1,002
Structural changes in the calcium pump accompanying the dissociation of calcium
Toyoshima, C., & Nomura, H. (2002) · Nature · doi:10.1038/nature00944 · Cited by 894
Molecular Physiology and Pathophysiology of Electroneutral Cation-Chloride Cotransporters
Gamba, G. (2005) · Physiological Reviews · doi:10.1152/physrev.00011.2004 · Cited by 810
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Current and droplet size in the electrospraying of liquids. Scaling laws
Gañán-Calvo, A. M., Dávila, J., & Barrero, A. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00433-8 · Cited by 780
Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry
Hernández, H., & Robinson, C. V. (2007) · Nature Protocols · doi:10.1038/nprot.2007.73 · Cited by 655
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Chemistry of Hofmeister Anions and Osmolytes
Zhang, Y., & Cremer, P. S. (2010) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093635 · Cited by 620
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Structure of concanavalin A at 2.4-Ang resolution
Hardman, K. D., & Ainsworth, C. F. (1972) · Biochemistry · doi:10.1021/bi00776a006 · Cited by 487
Hydrogen ion buffers for biological research
Ferguson, W. J., Braunschweiger, K. I., Braunschweiger, W. R., Smith, J. R., McCormick, J. J., Wasmann, C. C., Jarvis, N. P., Bell, D. H., & Good, N. E. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90079-2 · Cited by 465
Chen, D.-R., Pui, D. Y. H., & Kaufman, S. L. (1995) · Journal of Aerosol Science · doi:10.1016/0021-8502(95)00027-a · Cited by 456
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Rayleigh jets from levitated microdroplets
Duft, D., Achtzehn, T., Müller, R., Huber, B. A., & Leisner, T. (2003) · Nature · doi:10.1038/421128a · Cited by 433
Illingworth, J. (1987) · Biochemical Education · doi:10.1016/0307-4412(87)90120-8 · Cited by 365
Interrogating viral capsid assembly with ion mobility–mass spectrometry
Uetrecht, C., Barbu, I. M., Shoemaker, G. K., van Duijn, E., & Heck, A. J. R. (2011) · Nature Chemistry · doi:10.1038/nchem.947 · Cited by 267
Electrified droplet fission and the Rayleigh limit
Taflin, D. C., Ward, T. L., & Davis, E. J. (1989) · Langmuir · doi:10.1021/la00086a016 · Cited by 266
Droplet Evaporation and Discharge Dynamics in Electrospray Ionization
Smith, J. N., Flagan, R. C., & Beauchamp, J. L. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp025723e · Cited by 251
Spraying Mode Effect on Droplet Formation and Ion Chemistry in Electrosprays
Nemes, P., Marginean, I., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac062382i · Cited by 182
Mass Measurements of Increased Accuracy Resolve Heterogeneous Populations of Intact Ribosomes
McKay, A. R., Ruotolo, B. T., Ilag, L. L., & Robinson, C. V. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061468q · Cited by 178
Pulsation phenomena during electrospray ionization
Juraschek, R., & Röllgen, F. W. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14025-3 · Cited by 174
New perspectives of zinc coordination environments in proteins
Maret, W. (2012) · Journal of Inorganic Biochemistry · doi:10.1016/j.jinorgbio.2011.11.018 · Cited by 167
Xiang, F., Lin, Y., Wen, J., Matson, D. W., & Smith, R. D. (1999) · Analytical Chemistry · doi:10.1021/ac981400w · Cited by 143
Buffer Loading for Counteracting Metal Salt-Induced Signal Suppression in Electrospray Ionization
Iavarone, A. T., Udekwu, O. A., & Williams, E. R. (2004) · Analytical Chemistry · doi:10.1021/ac049724+ · Cited by 143
Self-citationMass spectrometry based tools to investigate protein–ligand interactions for drug discovery
Pacholarz, K. J., Garlish, R. A., Taylor, R. J., & Barran, P. E. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35035a · Cited by 141
Chowdhury, S. K., Katta, V., Beavis, R. C., & Chait, B. T. (1990) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(90)85018-h · Cited by 111
Wang, G., & Cole, R. B. (1994) · Analytical Chemistry · doi:10.1021/ac00093a026 · Cited by 109
Bound Anions Differentially Stabilize Multiprotein Complexes in the Absence of Bulk Solvent
Han, L., Hyung, S.-J., Mayers, J. J. S., & Ruotolo, B. T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203527a · Cited by 99
Electrospray Ionization from Nanopipette Emitters with Tip Diameters of Less than 100 nm
Yuill, E. M., Sa, N., Ray, S. J., Hieftje, G. M., & Baker, L. A. (2013) · Analytical Chemistry · doi:10.1021/ac402214g · Cited by 98
Grimm, R. L., & Beauchamp, J. L. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp907162w · Cited by 96
Quaternary Structure of Casein Kinase 2
Valero, E., Bonis, S. D., Filhol, O., Wade, R. H., Langowski, J., CHAMBAZ, E. M., & Cochet, C. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.14.8345 · Cited by 95
Hao, C., March, R. E., Croley, T. R., Smith, J. C., & Rafferty, S. P. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.107 · Cited by 94
Supercharging Protein Complexes from Aqueous Solution Disrupts their Native Conformations
Sterling, H. J., Kintzer, A. F., Feld, G. K., Cassou, C. A., Krantz, B. A., & Williams, E. R. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0301-y · Cited by 86
Self-citationDeMarco, M. L., & Burnham, C. D. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcpqyw3b6jlkilc · Cited by 86
Jiang, Y., & Hofstadler, S. A. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00024-1 · Cited by 82
Hu, P., & Gross, M. L. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00049a056 · Cited by 81
Zhou, M., Huang, C., & Wysocki, V. H. (2012) · Analytical Chemistry · doi:10.1021/ac300810u · Cited by 78
Nonspecific aggregation in native electrokinetic nanoelectrospray ionization
Davidson, K. L., Oberreit, D. R., Hogan, C. J., & Bush, M. F. (2016) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.09.013 · Cited by 75
Zinnel, N. F., Pai, P.-J., & Russell, D. H. (2012) · Analytical Chemistry · doi:10.1021/ac300193s · Cited by 74
Zhu, M. M., Rempel, D. L., Zhao, J., Giblin, D. E., & Gross, M. L. (2003) · Biochemistry · doi:10.1021/bi035188o · Cited by 74
Solution Additives that Desalt Protein Ions in Native Mass Spectrometry
Flick, T. G., Cassou, C. A., Chang, T. M., & Williams, E. R. (2012) · Analytical Chemistry · doi:10.1021/ac301629s · Cited by 73
Self-citationZhang, H., Cui, W., & Gross, M. L. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.06.019 · Cited by 68
Batchelor, J. D., Doucleff, M., Lee, C., Matsubara, K., Carlo, S. D., Heideker, J., Lamers, M. H., Pelton, J. G., & Wemmer, D. E. (2008) · Journal of Molecular Biology · doi:10.1016/j.jmb.2008.10.024 · Cited by 61
Desalting protein ions in native mass spectrometry using supercharging reagents
Cassou, C. A., & Williams, E. R. (2014) · The Analyst · doi:10.1039/c4an01085j · Cited by 60
Self-citationLi, Y., & Cole, R. B. (2003) · Analytical Chemistry · doi:10.1021/ac0301402 · Cited by 60
Pan, J., Xu, K., Yang, X., Choy, W., & Konermann, L. (2009) · Analytical Chemistry · doi:10.1021/ac900423x · Cited by 60
Mass spectrometry of intact ribosomes
Videler, H., Ilag, L. L., McKay, A. R., Hanson, C. L., & Robinson, C. V. (2004) · FEBS Letters · doi:10.1016/j.febslet.2004.12.003 · Cited by 59
van den Bremer, E. T. J., Jiskoot, W., James, R., Moore, G. R., Kleanthous, C., Heck, A. J. R., & Maier, C. S. (2002) · Protein Science · doi:10.1110/ps.0200502 · Cited by 59
Pródanov, M., Garrido, I., Vacas, V., Lebrón‐Aguilar, R., Dueñas, M., Gómez‐Cordovés, C., & Bartolomé, B. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.040 · Cited by 56
The Effect of Small Cations on the Positive Electrospray Responses of Proteins at Low pH
Pan, P., & McLuckey, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034344u · Cited by 54
Clarke, D. J., & Campopiano, D. J. (2015) · The Analyst · doi:10.1039/c4an02334j · Cited by 47
DeMuth, J. C., & McLuckey, S. A. (2014) · Analytical Chemistry · doi:10.1021/ac503865v · Cited by 45
Batchelor, J. D., Sterling, H. J., Hong, E., Williams, E. R., & Wemmer, D. E. (2009) · Journal of Molecular Biology · doi:10.1016/j.jmb.2009.08.033 · Cited by 40
Self-citationEffects of Metal Ion Adduction on the Gas-Phase Conformations of Protein Ions
Flick, T. G., Merenbloom, S. I., & Williams, E. R. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0664-3 · Cited by 29
Self-citationMortensen, D. N., & Williams, E. R. (2016) · The Analyst · doi:10.1039/c6an01380e · Cited by 18
Self-citation
Research works printed but not linked: 1
- Srikanth A., 2009, Open Appl. Phys. J., 53
Cited by
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
VanAernum, Z. L., Busch, F., Jones, B. J., Jia, M., Chen, Z., Boyken, S. E., Sahasrabuddhe, A., Baker, D., & Wysocki, V. H. (2020) · Nature Protocols · doi:10.1038/s41596-019-0281-0 · Cited by 169
Protein–Small Molecule Interactions in Native Mass Spectrometry
Bennett, J. L., Nguyen, G. T. H., & Donald, W. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00293 · Cited by 168
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Metadata
- Authors
- Susa, A. C., Xia, Z., & Williams, E. R.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Williams, Evan R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-22
- Volume
- 89
- Issue
- 5
- Pages
- 3116-3122
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2586632373
- Cited by
- 167
- References
- 59
- Citations by year
- 2026: 9 · 2025: 22 · 2024: 20 · 2023: 13 · 2022: 23 · 2021: 19 · 2020: 25 · 2019: 12 · 2018: 13 · 2017: 11
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM097357)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Keywords
- native mass spectrometry, protein complexes, electrospray ionization, intracellular environment, charge state distribution, droplet formation
- MeSH terms
- Alcohol Dehydrogenase, Animals, Buffers, Cattle, Proteins, Saccharomyces cerevisiae, Salts, Serum Albumin, Bovine, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.