CoChat

Native-MS Analysis of Monoclonal Antibody Conjugates by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Campuzano, Iain D. G., Netirojjanakul, Chawita, Nshanian, Michael, Lippens, Jennifer L., Kilgour, David P. A., Van Orden, Steve, Loo, Joseph A. · 2018 · Analytical Chemistry
Cited by 45

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Antibody-drug conjugates (ADCs) are an important class of therapeutic molecule currently being used to treat HER2-positive metastatic breast cancer, relapsed or refractory Hodgkin lymphoma, systemic anaplastic large cell lymphoma, relapsed or refractory B-cell precursor acute lymphoblastic leukemia, and acute myeloid leukemia. An ADC typically consists of a small molecule or peptide-based cytotoxic moiety covalently linked, via lysine or cysteine residues, to a monoclonal antibody (mAb) scaffold. Mass spectrometric (MS) characterization of these molecules affords highly accurate molecular weight (MW) and drug-to-antibody ratio (DAR) determination and is typically performed using orthogonal acceleration time-of-flight (oa-ToF) analyzers and more recently, Orbitrap instruments. Herein we describe for the first time the use of a 15 T solariX Fourier transform ion cyclotron mass spectrometer to characterize an IgG1 mAb molecule conjugated with biotin via native lysine and cysteine residues, under native-MS and solution conditions. The cysteine-biotin conjugates remained fully intact, demonstrating the ability of the FT-ICR to maintain the noncovalent interactions and efficiently transmit labile protein complexes. Native-MS was acquired and is displayed in magnitude mode using a symmetric Hann apodization function. Baseline separation is achieved on all covalent biotin additions, for each charge state, for both the lysine- and cysteine-biotin conjugates. Average DAR values obtained by native-MS for the lysine conjugate are compared to those derived by denaturing reversed phase liquid chromatography using an oa-ToF MS system (1.56 ± 0.02 versus 2.24 ± 0.02 for the 5 equivalent and 3.99 ± 0.09 versus 4.43 ± 0.01 for the 10 equivalent, respectively). Increased DAR value accuracy can be obtained for the higher biotin-load when using standard ESI conditions as opposed to nanoESI native-MS conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b03021

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Campuzano, I. D. G., Netirojjanakul, C., Nshanian, M., Lippens, J. L., Kilgour, D. P. A., Van Orden, S., & Loo, J. A.
Venue
Analytical Chemistry
Published
2017-12-18
Volume
90
Issue
1
Pages
745-751
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2775179273
Cited by
45
References
6
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.